Abstract
In this study, a DNA-based nanosensor using specific NH2 labeled single standard probe was developed against stn gene of Salmonella enterica in milk samples. The single-stranded DNA probe was immobilized on carboxylated multiwalled carbon nanotube and gold nanoparticle (c-MWCNT/AuNP) electrode using 1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC): N-hydroxy succinimide-based cross-linking chemistry. Electrochemical characterization was performed using cyclic voltammetry (CV) and Differential Pulse Voltammetry (DPV) techniques. The electrode surface at each step of fabrication was characterized using scanning electron microscopy. The sensitivity and lower limit of detection were found to be 728.42 (μA/cm2)/ng and 1.8 pg/6 μl (0.3 pg/ml), respectively, with regression coefficient (R2) of 0.843 using DPV. The sensor was further validated using raw and artificial milk samples, and results were compared with conventional methods of detection. The developed sensor was found to be highly sensitive and stable up to 6 months, with only 10% loss of initial peak current in CV analysis on storage at 4 °C.
Similar content being viewed by others
References
Alocilja EC, Zhang D, Shi C (2013) AuNP-DNA biosensor for rapid detection of Salmonella enterica serovar enteritidis. ACS Symp Ser 1143:43–53. https://doi.org/10.1021/bk-2013-1143.ch003
Das R, Sharma MK, Rao VK (2014) An electrochemical genosensor for Salmonella typhi on gold nanoparticles-mercaptosilane modified screen-printed electrode. J Biotechnol 188:9–16. https://doi.org/10.1016/j.jbiotec.2014.08.002
Dash SK, Sharma M, Khare S, Kumar A (2014) Carbon-mercaptooctadecane/carboxylated multi-walled carbon nanotubes composite based genosensor for detection of bacterial meningitis. Indian J Microbiol 54(2):170–177. https://doi.org/10.1007/s12088-013-0435-7
Díaz-Serrano M, Rosado A, Del Pilar J (2011) A Polymer-based electrochemical DNA biosensor for Salmonella: preparation, characterization, and calibration. Electroanal 23(8):1830–1841. https://doi.org/10.1002/elan.201000698
Dong J, Zhao H, Xu M (2013) Label-free electrochemical impedance immunosensor based on AuNPs/PAMAM-MWCNT-Chi nanocomposite modified glassy carbon electrode for detection of Salmonella typhimurium in milk. Food Chem 141(3):1980–1986. https://doi.org/10.1016/j.foodchem.2013.04.098
Hendriksen RS, Vieira AR, Karlsmose S et al (2011) Global monitoring of Salmonella serovar distribution from the World Health Organization Global Foodborne Infections Network Country Data Bank: results of quality assured laboratories from 2001 to 2007. Foodborne Pathog Dis 8(8):887–900. https://doi.org/10.1089/fpd.2010.0787
Jia F, Duan N, Wu S et al (2016) Impedimetric Salmonella aptasensor using a glassy carbon electrode modified with an electrode deposited composite consisting of reduced graphene oxide and carbon nanotubes. Microchim Acta 183(1):337–344. https://doi.org/10.1007/s00604-015-1649-7
Kaushal A, Kumar D, Khare S, Kumar A (2012) speB gene as a specific genetic marker for early detection of rheumatic heart disease in human. Mol Cell Biol 58(1):50–54. https://doi.org/10.1170/T920
Li Q, Cheng W, Zhang D et al (2012) Rapid and sensitive strategy for Salmonella detection using an InvA gene-based electrochemical DNA sensor. Int J Electrochem Sci 7(1):844–856
Ma X, Jiang Y, Jia F et al (2014) An aptamer-based electrochemical biosensor for the detection of Salmonella. J Microbiol Methods 98:94–98. https://doi.org/10.1016/j.mimet.2014.01.003
Nagraik R, Kaushal A, Gupta S et al (2019) Optimized DNA-based bioassay for Leptospira interrogans detection: a novel platform for leptospirosis diagnosis. 3 Biotech 9:284–291. https://doi.org/10.1007/s13205-019-1815-4
Ozdemir K, Acar S (2014) Plasmid profile and pulsed-field gel electrophoresis analysis of Salmonella enterica isolates from humans in Turkey. PLoS One 9(5):e95976. https://doi.org/10.1371/journal.pone.0095976
Parvej MS, Nazir KH, Rahman MB (2016) Prevalence and characterization of multi-drug resistant Salmonella enterica serovar Gallinarum biovar Pullorum and Gallinarum from chicken. Vet World 9(1):65–70. https://doi.org/10.14202/vetworld.2016.65-70
Pashazadeh P, Mokhtarzadeh A, Hasanzadeh M (2016) Recent advances in materials and methods for sensing Salmonella infections. Biosens Bioelectron 87:1050–1064. https://doi.org/10.1016/j.bios.2016.08.012
Savas S, Ersoy A, Gulmez Y et al (2018) Nanoparticle enhanced antibody and DNA biosensors for sensitive detection of Salmonella. Materials 11:1541. https://doi.org/10.3390/ma11091541
Silva Da, Ghica ME, Brett CM (2018) Gold nanoparticle decorated multiwalled carbon nanotube modified electrodes for the electrochemical determination of theophylline. Anal Methods 10(47):5634–5642. https://doi.org/10.1039/c8ay02150c
Singh S, Kaushal A, Khare S et al (2014) Mga genosensor for early detection of human rheumatic heart disease. Appl Biochem Biotechnol 173:228–238. https://doi.org/10.1007/s12010-014-0836-z
Taha EG, Mohamed A, Srivastava KK et al (2010) Rapid detection of Salmonella in chicken meat using immunomagnetic separation, CHROMagar, ELISA and real-time polymerase chain reaction (RT-PCR). Int J Poult Sci 9:831–835. https://doi.org/10.3923/ijps.2010.831.835
Xu H, Lee HY, Ahn J (2010) Growth and virulence properties of biofilm-forming Salmonella enterica serovar Typhimurium under different acidic conditions. Appl Environ Microbiol 76(24):7910–7917. https://doi.org/10.1128/AEM.01508-10
Zhu L, Zhao R, Wang K et al (2008) Electrochemical behaviors of methylene blue on DNA modified electrode and its application to the detection of PCR product from NOS sequence. Sens J 8(9):5649–5660. https://doi.org/10.3390/s8095649
Acknowledgements
The authors are thankful to Shoolini University, Solan, Himachal Pradesh for providing the facility to carry out the present research work. In addition, we would like to acknowledge scientific writing cell for the support provided towards language editing of the manuscript.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
There is no conflict of interest for authorship or related to any other context between authors.
Ethical standards
The authors have complied and worked within standard ethical norms.
Rights and permissions
About this article
Cite this article
Saini, K., Kaushal, A., Gupta, S. et al. Rapid detection of Salmonella enterica in raw milk samples using Stn gene-based biosensor. 3 Biotech 9, 425 (2019). https://doi.org/10.1007/s13205-019-1957-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s13205-019-1957-4