Statement of Novelty

For the first time a comparison of biomass washing and hydrothermal carbonization (HTC) including both the characterisation of solid and liquid products is presented.

Introduction

Biomass plays a crucial role in developing a future sustainable energy system. Already today, about three-quarters of the world’s renewable energy involve the use of biomass, with more than half consisting of traditional biomass use. Yet, there is a large untapped potential to further increase energetic biomass utilization. In particular, the exploitation of residual biomass waste streams seems favourable, considering no additional land-use or competition with food production is needed for its utilization. However, a large portion of available feedstock exhibit poor fuel quality such as high moisture content, inhomogeneity and low energy content which prohibit energy-efficient conversion in direct combustion or gasification. Other challenges in energetic biomass utilization arise from ash-related problems such as deposit formation, corrosion, ash-melting and particle formation [1,2,3]. These phenomena can be traced back to inorganic components like potassium (K) and chlorine (Cl) that are abundant in biomass feedstock. Furthermore, about 90% of the alkali metals and chlorine in biomass are present as water-soluble or ion-exchangeable compounds and are therefore susceptible to release during combustion [1, 4,5,6,7].

A possibility to overcome these shortcomings in fuel properties is a pre-treatment of feedstock prior to its thermal conversion. Washing and a thermo-chemical treatment by hydrothermal carbonisation (HTC) have proven to be effective in reducing the amount of alkali metals and Cl in the upgraded biofuels. Therefore they can be applied to control ash-related issues [8,9,10,11,12,13,14,15,16,17]. Both washing and HTC alter the inorganic fuel composition by the dissolution of soluble inorganics in the process water. In addition, several factors further promote the mobilisation of inorganic matter during HTC: In this process biomass is treated in hot compressed water at a temperature range of 150–300 °C. The process mimics the natural coalification process in a much faster time-scale and yields a sanitized solid product known as hydrochar or biocoal. A variety of different reactions occur during HTC, breaking down structural biomass components like hemi-cellulose and cellulose that contain a large proportion of the inorganic biomass constituents [18]. Consequently, biomass degradation might lead to a facilitation of inorganic species embedded in these structural components. Additionally, water under hydrothermal conditions has a lower density, viscosity and decreased polarity compared to water at ambient pressure and temperature [19]. These properties also potentially enhance removal of inorganics. Compared to biomass washing, HTC also helps to overcome problems associated with high moisture and low energy content of untreated feedstock. Hydrochar has increased heating value, higher hydrophobicity, and enhanced dewatering and storage properties.

A number of studies assessing the impact of washing on fuel quality exist: Turn et al. [10] have shown that up to 90% of K and 98% of Cl can be removed from banana grass by a multi-step washing procedure at ambient temperature. The impact of washing temperature from 30 to 90 °C and liquid-to-solid ratio (L/S ratio) on the removal efficiency of ash-forming matter was investigated by Deng et al. [15]. They found that higher washing temperatures lead to higher removal of ash forming constituents, while inorganic mobilisation was fluctuating at lower temperatures. Recently, an in depth study on the effect of particle size, washing temperature and duration as well as L/S ratio on fuel properties of wheat straw was published by Singhal et al. [13, 17]. They concluded that washing temperature has a high impact on fuel quality, improving higher heating value (HHV) and lowering fouling and slagging propensity, while L/S ratio and particle size are decisive parameters for the feasibility and efficiency of an industrial application of a washing pre-treatment step.

Studies also investigated the impact of HTC in inorganic biomass composition: Work by Smith et al. [11] and Reza et al. [12] has shown that HTC can reduce K and Cl contents by 80%–90% and 79%–100% respectively for a wide range of feedstock like willow, miscanthus, oak, greenhouse waste, food waste, secondary sewage sludge, digestate, macro-algae, microalgae and municipal waste. Smith et al. [20] also investigated the impact of pH during HTC on the combustion properties of swine manure. They found that pH had the highest impact on the mobilisation of phosphorous and alkali earth metals that were removed with higher efficiencies at lower pH levels.

To date, no comprehensive comparison between biomass upgrading by washing and HTC exists in the literature. Studies published on washing and HTC of biomass solely concentrate on the properties of the solid fuels while putting aside the characteristics of the effluents produced by both pre-treatment technologies. However, the characterisation of effluent from HTC and washing is critical for the economic and ecologic viability of the technologies. For example, in HTC per dry ton of hydrochar produced approximately 2 m3 of waste water is generated that needs to be treated at a cost [21,22,23].

Some studies characterise process water from HTC: Stemann et al. [24] and Wang et al. [25] investigated the effect of process water circulation on the properties of liquid and solid product from HTC of poplar wood and brown algae respectively. They showed that recirculation of process water increases mass yield and identified the main organic constituents in process water from hydrothermal treatment. Broch et al. [26] studied solid and liquid products from HTC of algae with a focus on high value liquid products in the process water. They showed that HTC converts approximately 1 wt.-% of the starting material to high value chemicals like malonic or lactic acid. Several other investigations exist that identify chemical constituents of process water [27,28,29,30]. Other studies focus on assessing the HTC carbon balance and evaluating the anaerobic digestibility of the process liquor by determining the biomethane production potential (BMP) [31,32,33,34,35,36]. To the author’s knowledge up to now, no comprehensive study exists on the characterisation of effluent from biomass washing. Abelha et al. [37] have determined COD and BMP for effluents from biomass washing in their techno-economic assessment of biomass washing and torrefaction, but do not explicitly report the obtained values.

Thus, the objective of the presented study is to compare the performance of washing and HTC in fuel upgrading and characterising the resulting effluents from the two pre-treatment technologies. For the first time, both, fuel properties and effluent characterisation is included. The study covers a variety of feedstock and process conditions: four different residual biomass substrates have been washed at 50 C and hydrothermally treated at temperatures ranging from 150 to 270 °C for a duration of 4 h. The L/S ratio is kept constant at 1:10. Fuel properties of raw, washed and HTC-treated feedstock are investigated and improvements concerning heating value and inorganic composition evaluated. Further, all fundamental waste water analysis parameters are covered. That includes organic pollutants by total organic carbon (TOC), chemical oxygen demand (COD), biological oxygen demand (BOD), nutrient concentration, as well as basic characterization of electrical conductivity (EC) and pH value. An assessment of the use of effluents in anaerobic digestion (AD) is provided on basis of COD and C/N ratio. The differences between washing and hydrothermal treatment are discussed.

Materials and Methods

Feedstock

Four different residual biomass feedstock were investigated in this study. Empty fruit bunches were imported from Malaysia, grass clippings and leaf litter were picked up from a local composting plant and olive pomace was retrieved from an oil mill in France. All feedstock were dried at ambient conditions and milled to a particle size below 1 mm prior to treatment.

HTC and Washing Experiments

Washing and HTC experiments were conducted in a stirred Parr Mini Reactor with a volume of 600 mL that is heated by three 700 W electrical heating jackets. In each experiment 30 g of dry feedstock and 300 mL deionized water were poured into the reactor. The system was then pressurized with argon and brought to reaction temperature at a heating rate of 7 K min−1. Throughout the experiment the pressure was kept constant with a backpressure regulator and temperature was controlled with an accuracy of ± 1 °C with a PID controller. After 4 residence time the reactor is air-cooled to room temperature and the slurry filtered to separate effluent and solid product. In this study biomass was carbonized at temperatures and pressure of 150 °C/20 bar, 180 °C/20 bar, 210 °C/40 bar, 240 °C/40 bar and 270 °C/80 bar. Water leaching of biomass was conducted in the same experimental set-up. 30 g of dry feedstock were mixed with 300 mL of deionized water. Water washing took place at 50 °C, ambient pressure and atmosphere in a stirred vessel.

Fuel Characterisation

The isolated solid product from washing and HTC was dried at ambient conditions prior to analysis. Proximate and ultimate analysis were conducted according to industrial standards: EN ISO 18134-3:2015 for the moisture content, EN14775:2009 for determination of ash content and ISO 562:1998 for the volatile content using a moisture analyzer Denver IR60 and a muffle furnace. The amount of fixed carbon was calculated by closing the mass balance. Ultimate analysis was done according to industrial standard method ISO/CD 12902:2006-11 using an elemental analyzer Vario Marco Cube from elementar. The chlorine content was determined in a similar device vario MACRO cube, also from elementar. The heating value was determined according to ISO 1928:1995 with bomb calorimeter C 200 from IKA. Ash compositions were determined by X-ray fluorescence (XRF) after complete combustion of the samples at 550 °C according to EN14775:2009. For ash composition analysis, the instrument Shimadzu EDX-800 HS was used. For the determination of ash composition Norm EN14775:2009 for fuel ashes by means of compressed tablets was used. The pellet contained 100 mg of the test ash and 20 mg of a wax binder. All measurements were repeated at least two times depending also on the required number of repetitions by the industrial norms. The industrial norms have strict rules for the threshold discrepancy between measurements above with the measurements needs to be repeated more often. The experimental repeatability was checked by repeating the treatment of EFB at 180 °C three times. The discrepancy between different experiments was found to be within an acceptable range (see supplementary material).

Effluent Characterization

Electrical conductivity and pH value were determined at room temperature following filtration with conductivity meter GMH 3431 and pH meter GMH 3511 from Greisinger. Subsequently, effluent samples were frozen and stored. Additional water characterisation was carried out by an external lab: TOC was determined according to EN 1484, DEV H3, BOD5 according to DIN EN 1899-1. COD, total phosphorous (Ptot), total nitrogen (TN), nitrate (NO3-N), nitrite (NO2-N) and ammonium (NH4-N) concentrations were characterised using Lange cuvette tests.

Results and Discussion

Fuel Characterisation

Mass- and Energy Yield, Heating Values

Table 1 shows the obtained mass- and energy yields as well as the results of proximate and ultimate analysis on dry basis after washing and hydrothermal treatment, respectively. Depending on the feedstock, around 72%–91% of the initial mass is obtained after water washing and filtration. After HTC, mass yield is lower and steadily decreases with increasing treatment temperature. At the lowest HTC temperature of 150 °C obtained mass yields are in the range of 58%–80%, while at the highest treatment temperature of 270 °C only 33%–50% of the initial mass is retained in the hydrochar. The mass loss after washing is a consequence of removal of extractives, i.e. water soluble non-structural biomass materials that are dissolved. Under hydrothermal condition more severe structural changes are induced: at around 150 °C decarboxylation of unstable carbonyl-groups takes place. The degradation of hemi-cellulose and cellulose starts at 180 °C and 220 °C respectively, leading to the formation of smaller water soluble organics. These fragments are removed with the process water, thereby decreasing mass yield at higher HTC temperatures. These transformations also lead to changes in elemental composition in the washed and HTC treated fuels respectively. Figure 1 shows a van Krevelen plot of atomic H/C and atomic O/C ratios that allows to identify the governing coalification mechanisms. Typical regions for biomass, peat, lignite and coal are indicated. The untreated biomass samples can be found in the upper right corner of the diagram in the typical biomass region. Washing leads to a slight decrease in atomic H/C of the washed material. HTC leads to more extensive changes in atomic H/C and O/C ratios and with increasing treatment temperature hydrochars become increasingly similar to a low-rank coal in terms of elemental composition. As Fig. 1 indicates, the coalification mechanism during HTC seems to be governed by dehydration and decarboxylation reactions, as previously described in detail [38, 39]. These transformations in elemental composition are accompanied by changes in lower heating value (LHV). HTC significantly increases LHV due to structural changes that ultimately lead to a higher carbon content in the hydrochar. LHV increases with increasing treatment temperature, i.e. hydrochar from olive pomace treated at 150 °C exhibits a LHV of 22.12 MJ kg−1, which increases to 30.52 MJ kg−1 for olive pomace treated at 270 °C. Similar increases in heating value have been reported in many other studies [11, 12, 21, 40, 41]. After washing, for EFB, grass clippings and olive pomace the obtained LHVs are slightly increased from 19.12 to 19.40 MJ kg−1, from 20.65 to 20.73 MJ kg−1 and from 17.08 to 17.92 MJ kg−1 respectively. This is in line with the findings from Singhal et al. [13], who also reported increased energy content after biomass washing. A reason for this could be removal of energy deficient extractives and, to a certain extent, removal of inorganic components. The LHV of fallen leaves was slightly reduced after washing.

Table 1 Proximate analysis, ultimate analysis, mass- and energy yield for untreated, washed and HTC treated biomass on dry basis
Fig. 1
figure 1

Van Krevelen diagram showing the composition of empty fruit bunches, grass clippings, leaf litter and olive pomace in raw condition and after washing or HTC treatment at different temperatures for 4 h

The energy efficiency of both processes can be assessed by considering the energy yield, that is calculated by multiplication of the obtained mass yield times the ratio of LHV of the treated and untreated biomass. After washing energy yield is generally higher than energy yield after HTC. For example, washing of olive pomace yields 85% of the biomass energy input, while after HTC at 180 °C 73% of the feedstock energy are recovered in the solid product. At higher HTC temperatures, the efficiency losses due to the dissolution of organic material to the process water can, to some extent, be compensated by a higher energy densification during. For example, while mass loss strongly decreases by 15 percentage points from 63 to 48% after increasing HTC temperature from 180 °C to 270 °C, energy yield only decreases by 7 points from 79% to 72%.

In conclusion one can say that HTC fundamentally changes biomass structure. This leads to more favourable fuel properties in terms of energy density, LHV and carbon content. Moreover, the structural changes also lead to altered fuel properties that are not investigated within the scope of this work but elsewhere [42,43,44]: HTC treated material has increased hydrophobicity, can be stored outdoors, is resistant to microbial deterioration and requires less milling energy. On the other hand, the changes of the organic structure induced by washing are much smaller. However, in most cases washing slightly increases LHV and leads to a reduced atomic H/C ratio due to the removal of extractives and ash forming matter.

Fate of Inorganic Elements

The ash content of untreated, washed and HTC treated biomass samples are shown in Fig. 2a. It can be seen that the development of ash concentration in the fuel is feedstock dependent: For EFB and olive pomace washing and HTC leads to a lower ash content after treatment. Washing EFB decreases ash content from 8.9 wt.-% to 5.9 wt.-%. HTC at 150 °C further decreases ash content to 5.3 wt.-%. Further increasing treatment temperature leads to a slight increase of ash content in HTC treated EFB to 7.1 wt.-% at 270 °C. Similar behaviour is noted for olive pomace. In contrast, when treating grass clippings and leaf litter by washing or HTC a higher ash content after the pre-treatment is observed. For these feedstock, increasing the treatment temperature above 150 °C increases the ash content of the treated material steeply. For example, washing of grass clippings increases ash content from 10.47 wt.-% to 11.44 wt.-%, after a treatment at 150 °C the ash content is slightly decreased to 9.37 wt.-%, before increasing to 15.82 wt.-% in biomass treated at 270 °C. These observations can be explained with two effects: On the one hand, the dissolution of soluble inorganics like e.g. alkali metals leads to a reduction of inorganics in the fuel and, thus, to a lower ash content after treatment. However, at the same time organic material is dissolved in the process water during treatment as well, leading to an increased relative inorganic concentration in the material. Consequently, ash content decreases if the amount of inorganic material removed exceeds the amount of organic material removed during the treatment. It seems ash content after washing and HTC is decreased for feedstock that exhibit a high concentration of soluble species like potassium in their ash. For example, potassium content in ash from EFB and olive pomace is 41.77 wt.-% and 59.52 wt.-% respectively. In contrast, silicon, phosphorous and calcium are main ash forming elements in substrates that show higher ash content after treatment. These are elements that are known to form less water soluble compounds in biomass and therefore are extracted to a lesser extent by washing and HTC. This observation is illustrated by Fig. 2b that shows the removal efficiency of washing and HTC for the main ash forming elements in EFB. The removal efficiency was calculated by subtracting the ratio of the inorganic element content of the hydrochar with the raw feedstock multiplied by the mass yield from 100 percent, as also applied by Smith et al. [11]. Ash analysis data for all other investigated feedstock is provided in the supplementary material. The following observations are discussed representatively for EFB. 70% of alkali metals are removed by washing of EFB. HTC increases this proportion with increasing treatment temperature to 96% for feedstock treated at 270 °C. The efficiency of washing and HTC in removing chlorine is also high: Washing removed 81% and HTC between 56–94% of chlorine from the feedstock. However, in this case, no clear trend with treatment temperature is observed. Consequently, the risk of chlorine induced corrosion is reduced after washing and HTC. Sulphur removal is 23% after washing of EFB. HTC sulphur extraction is much stronger and removes 78% at 150 °C and up to 88% at 270 °C. For earth alkali metals, phosphorous and silicon removal efficiencies are lower. HTC is more efficient than washing in removing earth alkali metals from EFB, increasing the proportion from 30% at washing conditions to 60% at 270 °C HTC conditions. Phosphorous removal seems to be higher after washing (61%) than after HTC, where the removed fraction of phosphorous decreases from 52% at 150 °C to 11% at 270 °C. This suggest that after a dissolution at lower temperatures P is reincorporated into the hydrochar during the treatment. For Si also lower overall removal efficiencies are observed. Washing removes 39% of the initially present Si. For HTC treated EFB, the Si removal efficiency shows no clear trend with treatment temperature and remains between 15% and 60%. Consequently, this study supports previous findings, that the inorganic removal efficiency of inorganics is highest for alkali metals and C, while removal of earth alkaline metals, Si and P is limited [9, 11, 12].

Fig. 2
figure 2

Ash content of raw, washed and HTC treated feedstock (a). Removal efficiency of washing and HTC in removing inorganic elements from EFB (b)

The effect of these changes in ash composition on fuel quality and ash related challenges can be assessed using fuel indices. Figure 3 shows the slagging index and base-to-acid ratio, an indicator for fouling tendency of untreated, washed and HTC treated samples. According to these indices, slagging and fouling has to be expected for all considered fuels. The highest slagging risk is expected for fuels from leaf litter, EFB poses the lowest slagging risk. The impact of washing and HTC on the slagging index is limited. Washing grass clippings and leaf litter increases the slagging index slightly, however for olive pomace and EFB a lower value, indicating higher slagging risk, is obtained. Similarly for HTC treated fuels for some substrates and process conditions, a slight amelioration of the slagging index is reached, while for others a higher risk of slagging after HTC has to be expected. In light of the findings on element removal, it is expected that the slagging index is not affected much by washing and HTC. It is calculated on the basis of the concentration of Si, Ca, Fe and Mg in the fuel ash. As discussed above, no strong removal on either of these inorganic species is observed in washing and HTC, therefore the impact of these pre-treatments on the slagging tendency is limited. On the other hand, washing and HTC have a stronger impact on fouling tendency, predicted by the base-to-acid ratio. For grass clippings washing reduces the B/A ratio from 2.4 to 1.9. HTC further decreases the B/A ratio with increasing treatment temperature, for example at 270 °C it is 1.3. Similar observations are made for the other substrates. However, also after pre-treatment a value of B/A below 0.45 is not reached, which is the threshold value for a low fouling risk. Thus, washing and HTC lessen but do not fully prevent fouling risk.

Fig. 3
figure 3

Slagging Index a and base to acid ratio b of raw, washed and HTC treated fuels

To sum up, both washing and HTC significantly decrease K and Cl concentration in biomass, ameliorating fuel properties with respect to ash-related challenges in biomass combustion. This leads to a lower risk for corrosion and fouling for washed or HTC treated fuels, while slagging tendency as indicated by the slagging index is not strongly altered after pre-treatment.

Effluent Characterisation

pH Value

The full set of water analysis data is presented in Table 2. The effluent pH value is in the acidic range for all samples. For effluents from washed materials the pH value lies between 4.7 and 6.7. Effluent obtained from the HTC experiments was generally more acidic with a range from 3.6 to 5.2. After HTC the obtained pH values are fairly similar and only minor differences between different feedstock can be observed. After washing differences between feedstock are more pronounced. pH levels after HTC are fairly stable when increasing treatment temperature from 150 °C to 270 °C. For EFB and leaf litter a slight decrease with increasing treatment temperature can be observed. For grass clippings and olive pomace on the other hand, pH slightly increases for increasing treatment temperature. Overall, a further increase in HTC temperature does not lead to further significant changes in pH value. The decrease of pH after HTC, as also reported by other researchers, can be explained with biomass degradation during HTC that leads of the formation of several organic acids such as acetic, formic, lactic and propionic acid [24, 26, 35, 45].

Table 2 Water analysis data of effluent obtained from washing and hydrothermal carbonisation at different temperatures of various feedstock

Electrical Conductivity

The electrical conductivity (EC) of the investigated effluent samples shows a high variability in the range of 1.9–6.3 mS cm−1. The highest conductivity is obtained for effluent from HTC of grass clippings. Compared to washing HTC yields higher EC in the effluent. Further increasing HTC treatment temperature does not seem to have a strong effect on the EC of the effluent obtained after reaction. Effluent from leaf litter and grass clippings shows a maximum in EC at about 210 °C, it decreases again for higher temperatures. EC slightly decreases in effluent form olive pomace with increasing treatment temperature, while no clear trend is seen for EFB. Compared to pH, a higher variability of EC with feedstock type is observed. The range in which the EC of sample effluent spreads seems to be feedstock dependent.

EC is directly related to the concentration of ions in the water. During washing and HTC soluble inorganics are extracted from biomass and are dissolved in the effluent water. Thus, the higher level of EC after HTC indicates that HTC is more efficient in the extraction of inorganics from the biomass matrix. After washing EC is lower compared to the EC of HTC effluent. There is no clear further trend of EC with temperature. Feedstock like EFB and grass clippings, which are rich in soluble alkali and earth alkali metals while also possessing high ash content, exhibit the highest EC in the resulting HTC effluent and washing effluent. The lowest ECs were measured for effluents from olive pomace that has a low ash content of 5 wt.-%.

Organic Matter and AD Usability

Table 2 shows the measured concentrations for total organic carbon (TOC), biological oxygen demand after 5 days (BOD5) and chemical oxygen demand (COD) in the effluent from biomass washing and HTC treatment of biomass. TOC values after washing lie within a range of 536–9650 mg l−1 Compared to this, TOC values are increased significantly after HTC and are within 6565–14,600 mg l−1. An exception to this is effluent from grass clippings where TOC of effluent from washed material reaches equally high TOC values as effluent originating from HTC. For comparison, Erdogan et al. [35] reported equally high values between 15,000 and 25,000 mg l−1 for effluent from HTC of orange pomace. Berge et al. [46] found concentrations of TOC in the range of 5000–35,700 mg l−1 in effluent from HTC of municipal biomass waste streams. These values indicate a heavy pollution of process water with organic material originating from biomass degradation processes during HTC. For EFB with increasing HTC temperature also an increase in TOC is observed. For the other feedstock, no clear development of TOC with temperature is noted. Again differences in TOC are governed by feedstock type with leaf litter exhibiting lower TOC values of up to approximately 15,000 mg l−1 in comparison to effluent from grass cuttings, olive pomace and EFB where TOC reaches values above 15,000 mg l−1. For BOD5 and COD similar observations can be made: COD of effluent obtained after washing is significantly lower than COD of effluent obtained after HTC of the same feedstock. COD values after washing show higher variance and reach values between 1602 and 25,240 mg l−1, whereas after HTC, COD values lie in a more narrow range of 15,410–37,500 mg l−1. COD of HTC effluents seems to be determined by feedstock type rather than treatment temperature. BOD5 values follow the same trends. After washing BOD5 values are significantly lower than after HTC. For example, effluent from washing of EFB yielded a BOD5 of 6380 mg l−1 and more than doubled to 15,040 mg l−1 in effluent from EFB HTC treated at 180 °C. Compared to the COD values the BOD5 values are relatively high. Consequently, a good biodegradability of the organic substances is to be expected. The BOD5/COD ratio for effluent from washing varies from 0.41 to 0.77, while the ratio is > 0.5 for all effluents originating from HTC treatment as shown in Fig. 4. If the ratio exceeds 0.5, the waste water is considered to be readily treatable by biological means. Interestingly, the ratio is increased after HTC for effluent from EFB, leaf litter and olive pomace which could possibly be a consequence of the breaking down of larger indigestible organic fragments during HTC to a size that is more easily digested by bacteria.

Fig. 4
figure 4

BOD5 to COD ratio a and C:N ratio b of effluent from washing and HTC of different biomass feedstock

Anaerobic digestion (AD) could help to access the chemical energy contained in the effluents from washing and HTC. Based on the presented data, a first indication on the potential biogas production from pre-treatment effluents can be made. Biogas production related to COD is about 0.5 l g−1 COD removed, corresponding to a methane production of roughly 0.35 l g−1 of COD removed [47]. For instance, for a full conversion of COD to methane, AD of process water could produce enough methane to cover between 10% and 20% of the thermal energy need of the process. This is assuming 2 m3 of effluent, a thermal energy consumption of 1.2 MWh per ton of HTC fuel produced as proposed in literature [21,22,23]. However a full COD conversion by AD is unlikely. Previous studies have shown that AD is able to eliminate between 50% and 75% of COD from HTC effluents [32, 48]. For other feedstock, the C/N ratio can be used as an indicator can be used to evaluate the possible efficiency of an AD process [49,50,51]. Fig. 4b shows the C/N ratio of the obtained effluents from washing and HTC of the different substrates. A value between 25 and 35 is considered optimal. Higher values point to rapid N depletion, causing lower gas production. A lower value indicates a protein-rich substrate that results in a higher pH causing methanogenic inhibition. Applying this criteria, an efficient AD conversion is expected for effluent from HTC of EFB and leaf litter. Compared to washing HTC of these feedstock increases C/N ratio to the desired range of roughly 25–35. C/N ratio of is below the optimum range for effluent from grass clippings and above the optimum range for effluent from olive pomace. However, C/N ratio can only serve as a preliminary assessment, the derived trends need to be verified by further experimental investigations.

Nutrient Contents

Table 2 shows the concentration of nitrogen nutrients (NO3-N, NH4-N, NO2-N) and total nitrogen (TN) as well as phosphorous (Ptot) determined in effluent samples from washing and HTC of the five investigated feedstock. Compared to the concentrations of organic matter their concentrations are significantly lower.

The most abundant nitrogen nutrient is NO3-N with a concentration of 13–117 mg l−1 in effluent from washing and 71–103 mg l−1 in effluent from HTC. When increasing the temperature of leaching from washing at 50 °C to 150 °C, first an increase of NO3-N in the resulting effluent is observed. When further increasing treatment temperature the concentration of NO3-N decreases again.

Ammonia-N (NH4-N) was found in concentrations of 0.5–20.4 mg l−1 and 0.6–4.8 mg l−1 were in effluent from washing and HTC respectively. For EFB and leaf litter a peak concentration of 34.4 mg l−1 and 25.6 mg l−1 was measured in effluent from HTC at 150 °C. In effluent obtained from HTC conducted at 180 °C and higher the concentration of NH4-N rapidly decreases to below 5 mg l−1 for all feedstock. This might indicate the precipitation of ammonia salts under hydrothermal conditions at temperatures above 150 °C, as also suggested by Kruse et al. [52].

Nitrite (NO2-N) was detected in low concentrations for washing 0.36–1.00 mg l−1 and HTC 0.30–1.12 mg l−1. Fluctuations in NO2-N concentrations are observed with treatment temperature, but no coherent trend is observed.

Overall, values obtained for TN in effluent are higher than measured NO3-N, NO2-N and NH4-N concentrations indicating the presence of more organic nitrogen species. After washing TN values are in the range of 25–484 mg l−1, being lower than TN concentrations after HTC. In HTC effluent TN concentrations of 107–1022 mg l−1 were obtained. TN concentration also is feedstock dependent: The highest TN concentrations were measured in effluent from grass clippings, which is also the feedstock that has the highest fuel-N content in the ultimate analysis as presented in Table 1. During washing and HTC nitrogen is released to the process water. The increase in TN at washing conditions can be explained by the dissolution of water soluble ammonium and nitrite salt and some nitrogen containing compounds to the washing water. At higher temperatures, i.e. at HTC conditions, hydrolysis of nitrogen containing compounds leads to a further increase of TN in the effluent.

Finally, Ptot values measured seem to be both temperature and feedstock dependent. Highest Ptot values are detected in effluent from grass clippings (up to 238 mg l−1), the lowest in effluent from leaf litter (up to 18 mg l−1). For all feedstock a decline in Ptot in effluent is observed with increasing treatment temperature. For example at washing conditions 238 mg ml−1 of phosphorous is detected in effluent from grass clippings. This value drastically decreases to only 53.4 mg ml−1 at HTC conditions of 150 °C and even lower to a value of 4.2 mg ml−1 in effluent originating from HTC of grass clippings at 270 °C. This finding also supports the observations made for phosphorous concentration in the biomass ash which, after an initial decline at washing conditions, increases again for higher treatment temperatures at HTC conditions, as also described by Smith et al. [11]. This suggests that at higher treatment temperature phosphorous is precipitated and reincorporated to the hydrochar.

Conclusion

The presented study reveals the impact of washing and hydrothermal carbonisation of several feedstock from different biomass types on fuel quality and process water characteristics. Regarding energy density, washing of biomass leads to minor improvements in heating value and elemental composition. In contrast, HTC fundamentally changes the elemental composition of the treated feedstock and increases LHVs drastically. Both washing and HTC alter the ash composition of treated feedstock and effectively remove potassium and chlorine, thus reducing the risk of ash-related issues in combustion processes like fouling and corrosion. For the selected feedstock, filtrates from washing and HTC are acidic and the measured electrical conductivity correlates with the amount of electrolytes dissolved in the process water. Both, washing and HTC yield process water that is highly contaminated with organic matter, however BOD5 to COD values indicate good biodegradability of the effluent. AD of the effluents offers 10–20% potential energy saving from methane production. However, for a reliable assessment of AD for effluent valorisation further studies, also investigating i.e. the formation of refractory substances are required. Nutrients occur in low concentrations in the effluent from washing and HTC.