Scenario
The rapid response team was called to evaluate a 64-yr-old hypotensive and hypoxic female patient hospitalized for deep venous thrombosis. Low-molecular-weight heparin had been initiated two days previously. The rapid response team observed her vital signs: heart rate, 110 beats·min−1; blood pressure, 90/65 mmHg; and oxygen saturation, 90% while receiving 100% oxygen via a non-rebreather face mask. Using bedside focused ultrasonography, the patient’s inferior vena cava was found to be < 2 cm and to collapse during inspiration. Lung ultrasonography revealed a spontaneous left-sided hemothorax. She was transferred to the intensive care unit, and a chest tube was inserted while coagulation was corrected using fresh frozen plasma. A chest radiograph confirmed the left-sided hemothorax. An inferior vena cava filter was inserted and the patient’s condition rapidly stabilized. She was discharged from hospital three days later.
Interpretation
This case illustrates the use of focused echocardiography in the presence of hemodynamic instability and hypoxemia.1,2 A diagnosis of pulmonary embolism was considered in this patient because of the history of deep venous thrombosis; however, within a minute, bedside ultrasonography revealed the presence of hypovolemia from a hemorrhagic shock secondary to a left-sided hemothorax. The diagnosis of hypovolemia is challenging and is discussed in more detail.
For decades, intravenous fluid administration has played a key role in the management of patients with hemodynamic instability such as septic and hypovolemic shock. A landmark study from Rivers et al. showed that a protocol of early goal-directed therapy partly based on volume optimization reduces organ failure and improves outcomes in patients with severe sepsis or septic shock.3 Uncorrected hypovolemia leading to inappropriate infusion of vasopressors may increase organ hypoperfusion and ischemia.4 On the other hand, hypervolemia and excessive fluid administration have been associated with increased complications and mortality.5,6 Based on these evidences, there is a compelling need for rapid reliable noninvasive methods to help clinicians assess the fluid responsiveness of their patients in situations of hemodynamic instability.
Clinical implications of hypovolemia
The first step in the management of hemodynamic instability is to recognize the clinical manifestations associated with this condition (Table 1). These variables are suggestive of tissue hypoperfusion and need to be corrected; however, these signs are non-specific and could be, for example, from a cardiogenic or non-cardiogenic etiology. In a clinical setting, fluid administration is then often considered. Nevertheless, clinical studies have shown that only 50% of hemodynamically unstable critically ill patients are volume responsive,7 i.e., they have increased their cardiac output following a fluid challenge. How can we show fluid responsiveness?
Based on the work by Guyton in a previous article on perioperative hemodynamic rounds,8 venous return is physiologically determined by the difference between mean systemic pressure and right atrial pressure divided by the resistance to venous return. During steady state, venous return is equal to cardiac output. Hypovolemia could be defined as a reduction in mean systemic venous pressure without any change in venous compliance. When volume is given, mean systemic pressure increases, leading to an increase in venous return. This is associated with an increase in right and left ventricular (LV) preload.8,9 According to the Frank-Starling principle, as the LV preload increases, stroke volume increases until the optimal preload is reached, at which point, the stroke volume will remain constant having reached the flat part of the curve.10 This relationship with preload (x axis) is related to cardiac output (y axis), as illustrated in Fig. 1. Curve A represents a patient with a normal cardiac function. A1 and A2 are on the ascending part of the curve, i.e., cardiac output can be increased by an increase in preload. We can see that A3 is on the flat part of the curve. An increase in preload will not have an effect on cardiac output even if cardiac function is normal. On the other hand, curve B represents a case of heart failure. On this curve, B1 will be responsive to a preload increment, B2 and B3 will not, being on the flat part of the curve. It is therefore important to determine the patient’s individual position on the Frank-Starling curve, since the only reason to give a fluid challenge would be to increase the patient’s stroke volume.
Static variables
For years, physicians have studied new ways of predicting fluid responsiveness. Traditionally, central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) have been used to guide fluid management in critically ill patients. These static variables reflect right and left atrial pressure, respectively. It has been shown that these two variables are inaccurate in predicting fluid responsiveness and should not be used to guide fluid management.11,12 Figure 2 summarizes common static variables, suggestive or not of fluid responsiveness. Both hemodynamic and two-dimensional Doppler echocardiographic variables can be used.
In patients monitored with a pulmonary artery catheter, CVP, PCWP, and right ventricular (RV) waveform analysis can be performed to estimate right and LV filling pressure. Figures 2A and 2B illustrate two markers currently used in our institution to help predict fluid responsiveness.13 Figure 2A represents a CVP or PCWP waveform with the a and v waves. A higher a wave in relation to the v wave (normal a/v ratio) is typically associated with normal ventricular filling pressures and cardiac function. Therefore, normal waveforms are more likely to predict fluid responsiveness. As shown in Fig. 2B, RV pressure waveform analysis can help identify normal or abnormal RV function. A horizontal diastolic slope represents normal RV compliance, normal RV diastolic function, normal filling pressures, and most likely fluid responsiveness. On the other hand, fluid responsiveness would be less likely if an oblique diastolic curve were observed, which corresponds to reduced RV compliance and high filling pressures.14
The two-dimensional echocardiographic measurements of the right and left end-diastolic areas have also been studied. The results of these studies show that these variables cannot always reliably predict fluid responsiveness except when they are continuously monitored and when the left ventricle is small and hyperkinetic, as shown in Fig. 2.15,16
In terms of Doppler variables, both LV filling pressures and PCWP can be estimated by the E/A ratio of the transmitral flow (TMF) Doppler signal. High E/A ratios represent high filling pressures. Preload reduction is associated with a reduction in filling pressure and a low E/A ratio.17,18 Lattik et al. observed that patients with a low to normal E/A ratio may be volume responders as opposed to patients with an elevated E/A ratio.19 Nevertheless, another study shows conflicting data regarding this observation.15 The combination of tissue Doppler imaging with TMF has been shown to reflect filling pressure more accurately than their use as single variables.20 Tissue Doppler imaging measures velocity at the level of the mitral valve annulus in contrast with TMF where the blood flow velocity is measured at the tip of the mitral valve in the LV cavity. In the operating room where hemodynamic changes are frequent, the combination of these modalities as predictors of fluid responsiveness has not been extensively studied and validated.
Dynamic variables
Using variations in venous return (preload) and cardiac output, dynamic variables have been proven to be much more reliable than static variables to assess fluid responsiveness, as shown in Table 2.10,16
Pulse pressure variation (PPV) and systolic pressure variation (SPV)—both derived from analysis of the arterial waveform—, stroke volume variation (SVV), and the variation of the amplitude of the pulse oximeter plethysmographic waveform are predictive of fluid responsiveness.7,21,22 These techniques use heart-lung interactions during mechanical ventilation. During inspiration, pleural pressure increases, causing a reduction in RV preload and an increase in RV afterload. The RV stroke volume is then reduced, which creates a decrease in LV filling and LV stroke volume two to three heart beats later.23 These changes are greater when the ventricles operate on the steep part of the Frank-Starling curve, i.e., fluid responders should experience greater change in these variables compared with non-responders who operate on the flat part of the curve. A variation > 12% of these values has been reported to be highly predictive for fluid responsiveness.7,10 The SPV in a passive patient with mechanical ventilation is illustrated in Fig. 3A. Right atrial pressure and CVP, its surrogate, respiratory variations are also predictive of fluid responsiveness as shown in Fig. 3B.24
These approaches have several limitations. Arrhythmias and spontaneous respiration will influence the measured responses. These respiratory variations cannot be used in an open chest condition such as cardiac surgery. Also, De Backer et al. have shown that PPV is unreliable when tidal volume is < 8 mL·kg−1, i.e., larger tidal volumes are needed to induce these respiratory variations.25 Pulse contour-based hemodynamic monitoring devices, such as the FloTrac-Vigileo™ (Edwards Lifesciences, Irvine, CA, USA), the most recent and most widely studied device, have inherent inaccuracies. As shown in a recent review, these devices may provide variable SVV measurements in situations of low systemic vascular resistance, including septic shock, and problems may be encountered when tracking changes in stroke volume after a volume challenge or after the use of vasopressors.26 Nevertheless, these devices are much more reliable and accurate for measuring PPV, which does not use pulse contour analysis.7 This suggests that PPV should then be the variable used with these devices.
Echocardiographic evaluation of the respiratory changes in the diameter of the two venae cavae can also help predict fluid responsiveness. Using a subxiphoid view in completely passive patients with mechanical ventilation, inferior vena cava respiratory variation has been associated with a positive fluid responsiveness,27,28 as shown in the current case and in Fig. 4. Either M-mode, as shown in Figs. 4 and 5, or direct visualization could then be used. This variable is not as sensitive in mechanically ventilated patients.29 The superior vena cava (SVC) can be assessed using transesophageal echocardiography. Its cyclic collapsibility is also related to fluid responsiveness (Fig. 5).30
Echocardiographic assessment of static and dynamic parameters of fluid responsiveness needs to be performed by an experienced operator. The clinician’s expertise is thus the major limiting factor. Figure 3 summarizes common dynamic variables, suggestive or not of fluid responsiveness.
Passive leg raising as a marker of fluid responsiveness
Since dynamic variables cannot be used in spontaneously breathing patients, new variables have been studied to predict fluid responsiveness. Passive leg raising (PLR), as shown in Fig. 3E, induces a transfer of blood from the lower limbs to the intrathoracic compartment, creating an intrinsic volume challenge of 350 mL.31 This action has the benefit of being reversible, applicable to the bedside, maximal in 60 sec, and will not create fluid overload.32 Passive leg raising has been validated to predict fluid responsiveness in both spontaneous breathing patients and passive patients with mechanical ventilation,33,34 but it is not reliable in the presence of abdominal hypertension.35,36 To assess the maximal hemodynamic effects of PLR, cardiac output and stroke volume variations must be continuously monitored. Transthoracic echocardiography, esophageal Doppler, pulse contour analysis, and femoral Doppler have all been validated in this situation, as shown in a recent meta-analysis.34 This same meta-analysis confirms the excellent value of PLR to predict fluid responsiveness with an area under the receiver operating curve of 0.95, which is best among the different dynamic variables, as shown in Table 2. Recently, end-tidal carbon dioxide (ETCO2) has also proved its reliability as a surrogate to cardiac output measurement to predict fluid responsiveness with PLR.37,38
Finally, once it has been established whether or not there is fluid responsiveness in the presence of hemodynamic instability, the next step is to determine why the patients became fluid responsive. In the current case, two possibilities were contemplated: loss of volume (hypovolemic or hemorrhagic shock) or increased venous compliance such as septic shock. Point-of-care echocardiography can be used for rapidly identifying or ruling out the presence of blood in the thoracic and abdominal cavity, but it can also be used to identify conditions associated with septic shock, such as pneumonia, empyema, peritonitis, liver abscess, cholecystitis, and pyelonephritis.
In conclusion, assessing fluid responsiveness is an important feature in the management of patients with hemodynamic instability. In our experience, we do not rely on one variable alone. Combinations of multiple signs are more useful. In some patients, fluid responsiveness can be diagnosed easily using PLR, but in others, it is more complex. Occult hypoperfusion can still occur despite what seems to be adequate fluid resuscitation. The use of such modalities as the renal or splenic Doppler resistance index in trauma is promising for identifying those patients at the bedside, but these modalities will need further confirmation in critically ill patients.39,40 Dynamic variables are most useful in finding the patient’s individual point on the Frank-Starling curve.
References
Piette E, Daoust R, Denault A. Basic concepts in the use of thoracic and lung ultrasound. Curr Opin Anaesthesiol 2013; 26: 20-30.
Labovitz AJ, Noble VE, Bierig M, et al. Focused cardiac ultrasound in the emergent setting: a consensus statement of the American Society of Echocardiography and American College of Emergency Physicians. J Am Soc Echocardiogr 2010; 23: 1225-30.
Rivers E, Nguyen B, Havstad S, et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001; 345: 1368-77.
Murakawa K, Kobayashi A. Effects of vasopressors on renal tissue gas tensions during hemorrhagic shock in dogs. Crit Care Med 1988; 16: 789-92.
Vincent JL, Sakr Y, Sprung CL, et al. Sepsis in European intensive care units: results of the SOAP study. Crit Care Med 2006; 34: 344-53.
Boyd JH, Forbes J, Nakada TA, Walley KR, Russell JA. Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality. Crit Care Med 2011; 39: 259-65.
Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 2009; 37: 2642-7.
Deslauriers N, Dery R, Denault A. Acute abdominal compartment syndrome. Can J Anaesth 2009; 56: 678-82.
Guyton AC, Lindsey AW, Abernathy B, Richardson T. Venous return at various right atrial pressures and the normal venous return curve. Am J Physiol 1957; 189: 609-15.
Marik PE, Monnet X, Teboul JL. Hemodynamic parameters to guide fluid therapy. Ann Intensive Care 2011; 1: 1.
Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008; 134: 172-8.
Osman D, Ridel C, Ray P, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med 2007; 35: 64-8.
Roy S, Couture P, Qizilbash B, et al. Hemodynamic pressure waveform analysis in predicting fluid responsiveness. J Cardiothorac Vasc Anesth 2013; 27: 676-80.
Denault AY, Haddad F, Jacobsohn E, Deschamps A. Perioperative right ventricular dysfunction. Curr Opin Anesthesiol 2013; 26: 71-81.
Solus-Biguenet H, Fleyfel M, Tavernier B, et al. Non-invasive prediction of fluid responsiveness during major hepatic surgery. Br J Anaesth 2006; 97: 808-16.
Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 2002; 121: 2000-8.
Appleton CP, Galloway JM, Gonzalez MS, Gaballa M, Basnight MA. Estimation of left ventricular filling pressures using two-dimensional and Doppler echocardiography in adult patients with cardiac disease. Additional value of analyzing left atrial size, left atrial ejection fraction and the difference in duration of pulmonary venous and mitral flow velocity at atrial contraction. J Am Coll Cardiol 1993; 22: 1972-82.
Nomura M, Hillel Z, Shih H, Kuroda MM, Thys DM. The association between Doppler transmitral flow variables measured by transesophageal echocardiography and pulmonary capillary wedge pressure. Anesth Analg 1997; 84: 491-6.
Lattik R, Couture P, Denault AY, et al. Mitral Doppler indices are superior to two-dimensional echocardiographic and hemodynamic variables in predicting responsiveness of cardiac output to a rapid intravenous infusion of colloid. Anesth Analg 2002; 94: 1092-9, table.
Nagueh SF, Middleton KJ, Kopelen HA, Zoghbi WA, Quinones MA. Doppler tissue imaging: a noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures. J Am Coll Cardiol 1997; 30: 1527-33.
Natalini G, Rosano A, Taranto M, Faggian B, Vittorielli E, Bernardini A. Arterial versus plethysmographic dynamic indices to test responsiveness for testing fluid administration in hypotensive patients: a clinical trial. Anesth Analg 2006; 103: 1478-84.
Feissel M, Teboul JL, Merlani P, Badie J, Faller JP, Bendjelid K. Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients. Intensive Care Med 2007; 33: 993-9.
Michard F, Teboul JL. Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation. Crit Care 2000; 4: 282-9.
Magder S, Georgiadis G, Cheong T. Respiratory variations in right atrial pressure predict the response to fluid challenge. J Crit Care 1992; 7: 76-85.
De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 2005; 31: 517-23.
Marik PE. Noninvasive cardiac output monitors: a state-of the-art review. J Cardiothorac Vasc Anesth 2013; 27: 121-34.
Feissel M, Michard F, Faller JP, Teboul JL. The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med 2004; 30: 1834-7.
Barbier C, Loubieres Y, Schmit C, et al. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 2004; 30: 1740-6.
Muller L, Bobbia X, Toumi M, et al. Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use. Crit Care 2012; 16: R188.
Vieillard-Baron A, Chergui K, Rabiller A, et al. Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med 2004; 30: 1734-9.
Rutlen DL, Wackers FJ, Zaret BL. Radionuclide assessment of peripheral intravascular capacity: a technique to measure intravascular volume changes in the capacitance circulation in man. Circulation 1981; 64: 146-52.
Monnet X, Teboul JL. Passive leg raising. Intensive Care Med 2008; 34: 659-63.
Preau S, Saulnier F, Dewavrin F, Durocher A, Chagnon JL. Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis. Crit Care Med 2010; 38: 819-25.
Cavallaro F, Sandroni C, Marano C, et al. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med 2010; 36: 1475-83.
Mahjoub Y, Touzeau J, Airapetian N, et al. The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension. Crit Care Med 2010; 38: 1824-9.
Malbrain ML, Reuter DA. Assessing fluid responsiveness with the passive leg raising maneuver in patients with increased intra-abdominal pressure: be aware that not all blood returns! Crit Care Med 2010; 38: 1912-5.
Monnet X, Bataille A, Magalhaes E, et al. End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. Intensive Care Med 2013; 39: 93-100.
Monge Garcia MI, Gil CA, Gracia Romero M, et al. Non-invasive assessment of fluid responsiveness by changes in partial end-tidal CO2 pressure during a passive leg-raising maneuver. Ann Intensive Care 2012; 2: 9.
Corradi F, Brusasco C, Vezzani A, et al. Hemorrhagic shock in polytrauma patients: early detection with renal Doppler resistive index measurements. Radiology 2011; 260: 112-8.
Corradi F, Brusasco C, Garlaschi A, et al. Splenic Doppler resistive index for early detection of occult hemorrhagic shock after polytrauma in adult patients. Shock 2012; 38: 466-73.
Denault AY, Couture P, Vegas A, Buithieu J, Tardif JC. Transesophageal Echocardiography Multimedia Manual. Second Edition. A Perioperative Transdisciplinary Approach. 2nd ed. London: Informa Healthcare; 2010 .
Schneider AJ, Teule GJ, Groeneveld AB, Nauta J, Heidendal GA. Thijs LGl. Biventricular performance during volume loading in patients with early septic shock, with emphasis on the right ventricle: a combined hemodynamic and radionuclide study. Am Heart J 1988; 116: 103-12.
Kusumoto FM, Muhiudeen IA, Kuecherer HF, Cahalan MK, Schiller NB. Response of the interatrial septum to transatrial pressure gradients and its potential for predicting pulmonary capillary wedge pressure: an intraoperative study using transesophageal echocardiography in patients during mechanical ventilation. J Am Coll Cardiol 1993; 21: 721-8.
Royse CF, Royse AG, Soeding PF, Blake DW. Shape and movement of the interatrial septum predicts change in pulmonary capillary wedge pressure. Ann Thorac Cardiovasc Surg 2001; 7: 79-83.
Acknowledgements
The authors sincerely thank Antoinette Paolitto and Denis Babin for their help with the manuscript.
Conflicts of interests
None declared.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Toupin, F., Denault, A., Lamarche, Y. et al. Hemodynamic instability and fluid responsiveness. Can J Anesth/J Can Anesth 60, 1240–1247 (2013). https://doi.org/10.1007/s12630-013-0036-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12630-013-0036-2