Introduction

Recently, food safety has become a vital issue to the general public, medical, nutritional experts, and food science researchers. Food additives are widely used to confer a desirable appearance and enhance the nutritional properties of commercial products (Ntrallou, 2020; Bordagaray, 2018; Bordagaray, 2019). Colorants are chemicals which are applied during development or processing of foods and soft drinks. However, some of these chemicals represent potential risks to human health and result in adverse effects like metabolic acidosis, tremors, and hyperpnoea (Sorouraddin, 2015), especially if they are used in exceeded amounts (Sierra-Rosales, 2017). Therefore, regulated use of these colorants in different food items must be ensured (Islam, 2019).

Children are the most vulnerable as they consume a lot of candies and drinks, especially those rich in synthetic colorants. Owing to their lower weight relative to adults, acceptable daily intake values (ADIs) are easily reached so that the adverse effects are more obvious in this population. Centered on agencies’ international guidelines, such as the U.S. Department of Agriculture (USDA) and the U.S. Food and Drug Administration (FDA), all food colorants must be listed (Mazdeh, 2016). The analysis of food needs quick methods for routine control and high sample throughput. Chromatographic separation allows multiple compounds in complex matrices to be quantified simultaneously, many methods have been involved to improve separation efficiency and decrease the time of analysis (Lhotská, 2018).

The investigated synthetic colorants were (Tartrazine, Sunset Yellow, Allura Red, Carmoisine, and Brilliant Blue). Chemical structures, numbers of the European community (E numbers), and denominations of the color index (CI numbers) were represented in (Fig. S1). Upon observation, they were among the dyes most labeled in Egyptian food products such as ice cream, puddings, sweets, drinks, and chewing gums; however, their concentrations were not mentioned. Mentioning their concentrations is valuable to be sure that ADIs are not exceeded particularly by young children. This work aimed to monitor various Egyptian food products which are consumed daily especially by children, using fast simple methods. Chromatographic analysis was successfully performed on 65 food products.

Various analytical approaches have been reported to determine a wide variety of synthetic food colorants, like thin-layer chromatography (TLC) (Oka, 1994; de Andrade, 2014), adsorptive voltammetry (Ni, 1997), differential pulse polarography (Combeau, 2002), and electrophoresis (Cifuentes, 2006; Dossi, 2007; Prado, 2006). However, most of them require time-consuming pretreatment and cannot be applied to complicated color mixtures (Mazdeh, 2016). Different chromatographic methods have been reported including HPLC with UV detection (Demiralay, 2006; Garcı́a, 2003; Lino, 2010; Saad, 2005; Techakriengkrai, 2007; Tfouni, 2002; Brazeau, 2018), ion chromatography with UV detection (Dossi, 2006), molecular absorption spectrophotometry (Cantarelli, 2009), GC using flame ionization detection (Dong, 2006, Wang,2006), flow injection analysis (FI) with the aid of UV detection ( García-Jiménez, 2007; García‐Jiménez, 2006). High-performance ion chromatography (Lucena, 2005), reversed-phase liquid chromatography (Garcıa-Falcón, 2005; Kirschbaum, 2003; Prado, 2002; Mathiyalagan, 2019), and ion-pair liquid chromatography (Fuh, 2002; Gianotti, 2005; González, 2003; Gallego, 2003; Ishikawa, 2003; Kiseleva, 2003). There were some methods to determine the studied colorants in presence of others in different matrices using HPLC with UV/Vis or photodiode array detection (Al-Degs, 2009; Enríquez-Gabeiras, 2012; Kirschbaum, 2006; Long, 2009; Olgun,2012; Serdar, 2009; Iammarino, 2019). HPLC coupled with UV/Vis or DAD detection is the most common approach as colorants are highly absorbed at the UV and/or visible wavelength. UPLC-MS/MS methods for analysis of colorants in foods have also been reported (Chen, 2014; Gao, 2015; Guerra, 2018; Tsai, 2013; Zou, 2013). Ultraviolet (UV) detectors were replaced by MS detectors as they provide more structural details and can adhere to the confirmatory process requirements set out in European Commission Decision 2002/657/EC. Recently, E102,E110, E122, E129, and E 133 were separated in the presence of some other colorants in food products consumed by children in Saudi Arabia using only an HPLC–DAD method and the method developed was not completely validated (Ahmed, 2021), while E102, E110, E129, and E 133 were separated in the presence of some other colorants in only chewing gums and soft drinks present in Korea using HPLC–DAD method and LC–MS/MS method, where the limit of detection of the HPLC–DAD method was almost similar to our proposed HPLC–DAD method while the limit of detection of our LC–MS/MS method was lower than the reported LC–MS/MS method (Jang,2021). Also, E102,E110, E129 were separated using HPLC–UV method in soft drinks, powder juice and candies (Al-Khateeb, 2021). Nguyen has separated E102,E110, E122, E129, and E 133 in the presence of other colorants in food products in Korea (Nguyen, 2021), using only HPLC–DAD method with longer run time and higher limit of detection than our method.

In our study, a reversed-phase high-performance liquid chromatography with diode array detector (RP-HPLC–DAD) method and a UPLC-ESI–MS/MS method were developed for the determination of five water-soluble synthetic food colorants (E102, E110, E129, E122, and E133) in a set of 65 food products present in the Egyptian market. These colorants were chosen owing to their abundance among food products in the local market in Egypt. The proposed methods included a simple pretreatment procedure for the samples and allowed the detection of colorants at very low concentrations. It is worth mentioning that this study is considered to be the first one to determine the concentrations of the synthetic food colorants (E102, E110, E129, E122, and E133) in a wide variety of food products such as sweets, drinks, ice cream powders, puddings, and chewing gums in the Egyptian market, which are consumed mainly by children, and to compare the results with international limits.

Experimental

Materials and Reagents

High purity standard of Tartrazine (E102) (99.1% purity), Sunset Yellow (E110) (98.1% purity), Allura Red (E129) (98.1% Purity), Carmoisine (E122) (98.0% purity), and Brilliant Blue (133) (98.5% purity) were obtained from Sigma-Aldrich. HPLC-grade methanol was obtained from Fisher Scientific. Ammonium acetate (98%) and acetonitrile (HPLC grade) were purchased from Sigma-Aldrich. The ultra-pure water was prepared by distillation in glass and passage through a Milli-Q water system, passed through a 0.45-μm membrane filter, and degassed for 30-min in an ultrasonic bath. Food samples were purchased from Egyptian supermarkets.

RP-HPLC–DAD Analysis

The HPLC separation and quantitation were achieved on Waters LC 2695, (Milford, MA, USA) with a gradient pump using low-pressure mixing system, vacuum membrane degasser, an autosampler with a 100 μl sample loop and a capacity of 120 vials, and a Waters module 2996 photodiode array detector. The column C18 (100 mm × 4.6 mm (i.d.)) packed with Inertsil ODS-3 V (5-μm particle diameter, GL Sciences, Tokyo, Japan) and an HPLC column oven (DALIAN REPLETE®, Hong Kong) was used. Waters Empower software was used for Data acquisition. The mobile phase consisted of eluent A, water containing 1% ammonium acetate (with pH 6.8, adjusted with ammonium hydroxide); and eluent B, acetonitrile. RP-HPLC–DAD assay was carried out by constructing a gradient elution program of 5% B at 0–3 min, 10% B at 3–9 min, 40% B at 9–9.5 min, and 70% B at 9.5–12 min. In the end, a 3 min equilibrium phase to the column was made to recover first condition of 95% A: 5% B for the next run. The acquisition wavelength of DAD was set to scan between 200 and 800 nm. At column temperature 25 °C, all determinations were performed. The injected volume was 20 μL and the run time was 12 min. The flow rate set at 1.0 mL min−1. The mobile phase was filtered through a 0.45-μm membrane filter and degassed under vacuum prior to use.

UPLC-MS/MS Analysis

Separation was made on a Waters 3100 instrument (Milford, MA, USA) with a binary solvent manager pump, autosampler, and thermostatic column compartment. An API 5000 triple quadrupole (TQ detector, Acquity UPLC, USA) was the tandem mass spectrometer. A UPLC acquity® BEH shield RP18 column (150 mm × 2.1 mm, 1.7 μm) was used. Mass lynx software (Version 4.1) was used for data analysis and system operation. UPLC/MS/MS assay was carried out using an isocratic system with a flow rate of 0.3 mL min−1. Acetonitrile: 4 mM ammonium acetate (80:20, v/v) was the mobile phase. By electrospray ionization mass spectrometry, mass spectra were obtained simultaneously in negative mode (ESI/MS). The injected volume was 2 μl through a 3-min run time.

The tuning parameters were set for detection of the investigated colorants optimally: desolvation temperature, 400 °C; ion source temperature, 120 °C; capillary voltage, 3.5 kV; desolvation gas flow, 600L/h. The proper collision energy, cone voltage and representative product ions values for these five colorants were listed in Table 1.

Table 1 The optimum UPLC-MS/MS parameters and selected typical fragment ions for the studied synthetic colorants

Preparation of Standards of Colorants and Calibration

Dissolving 10.0 mg of pure coloring agents into 10.0 mL of methanol was used to prepare individual standard stock solutions containing each colorant. The solutions were freshly prepared, tightly closed to amber colored volumetric flasks, and kept at 4 °C. For calibration of HPLC method, these stock solutions were diluted with methanol to obtain working standard solutions of suitable concentrations within the concentration range (0.5–50 μg mL−1). For calibration of UPLC-MS/MS method, accurate volumes of each of E102, E110, E129, E122, and E133 stock solutions were transferred into volumetric flasks (10 mL) and diluted to volume with methanol to make synthetic mixtures in the concentration range (0.01–5 µg mL−1) of each compound.

Preparation of Commercial Samples

All of the sixty five tested samples were brought from the Egyptian markets and categorized to four categories: jelly powders, puddings, ice cream powders (A), concentrated fruit-flavored soft drinks powders (B), carbonated fruit-flavored drinks (C), chewing gums, candy smartiz, and sugar confectionery(D). Category A samples were numbered from A 1 to A28, category B samples were numbered from B 29 to B43, category C samples were numbered from B 44 to B51, and category D samples were numbered from B 52 to B65.

Samples Analyzed by RP-HPLC–DAD Technique

Treatment of Carbonated Fruit-Flavored Drinks

Twenty-five milliliters of the sample were adequately transferred to a 50-mL volumetric flask and 20 mL of HPLC water was added. The samples were subjected to sonication for 15 min and completed with HPLC water to the mark. After filtering through 0.45-μm disposable syringe filters, 20 μl of the solutions were injected.

Treatment of Concentrated Fruit-Flavored Soft Drink Powders

Two grams of each sample was weighed and diluted with 30 mL HPLC water in a 50-mL volumetric flask. The samples were subjected to sonication for 15 min and completed to the mark with HPLC water. After filtering through 0.45-μm disposable syringe filters, all solutions were injected (20 μl).

Treatment of Jelly Powder, Ice Cream Powder, Puddings, and Mehalabia

Two grams of each sample was weighed and diluted with HPLC water in a 25-mL volumetric flask. The sample solutions were subjected to sonication for 15 min and completed with HPLC water to the mark. After filtering through 0.45-μm disposable syringe filters, all solutions were injected (20 μl).

Treatment of Chewing Gums, Candy Smartiz, and Sugar Confectionary

Five grams of each sample was weighed then sliced and transferred to a beaker containing 5 ml of 1% ammonia solution (Khanavi, 2012). Twenty-five milliliters of HPLC water was added, the sample solutions were subjected to sonication for 30 min, filtered through a folded filter paper, and the filtrate was collected in a 50-ml volumetric flask and completed with water. After filtering through 0.45-μm disposable syringe filters, the solutions were injected (20 μl).

Samples Analyzed by UPLC-MS/MS Technique

The selected samples (A5, A11, A13, A19, B31, B40, B41, B42, B43, and D 53) were treated as follows: accurately, 0.5 gm of each sample was weighed and dissolved in 10 mL of water (50 mg/mL), except savory red sampleD53) was diluted to 5 mg/mL, as it is highly concentrated and vortexed for 1 min. All solutions were subjected to sonication for 30 min and further diluted by HPLC water. All sample solutions were filtered by a 0.22-μm syringe filter then injected.

Results and Discussion

Optimization of the Separation

Optimization of the HPLC–DAD Method

Many mobile phase compositions have been tried, methanol and phosphate buffer (50:50, v/v); methanol and phosphate buffer (70:30, v/v), methanol and ammonium acetate buffer (80:20, v/v); methanol and ammonium acetate solution 1% (w/v) (70:30,v/v); and acetonitrile and ammonium acetate buffer (20:80, v/v). The separation was poor for these trials. E122 and E133 colorants were not well separated and the peaks E102 and E110 were forked. Isocratic elution was not appropriate and gradient elution was then tried to achieve better separation. The use of gradient elution to separate colorants was also present in previous methods (Kirschbaum, 2003; Serdar, 2009; Iammarino, 2019; Filiz, 2019; Ahmed, 2021, Jang, 2021). Different amounts of ammonium acetate in the mobile phase were tested. Experiments and a reported method (Minioti, 2007) revealed that the most effective amount for ammonium acetate is 1% (w/v). Different pH values for the ammonium acetate buffer were also examined (6, 6.8, 7.5, and 7.9), and increasing pH to more than 7 leads to poor resolution. Several time programs with different initial percentage of acetonitrile were tested, increased acetonitrile concentration to more than 10%, resulted in insufficient separation and characteristic overlap of E122 and E133 colorants, while lower acetonitrile concentration (about 5%) resulted in excessive tailing and longer retention time of E133. Different column temperatures were examined (25 ºC, 30 ºC, and 35 ºC) and no significant effect was observed upon increasing temperature more than 25 ºC. The best results were achieved by using mobile phase consisting of water containing 1% ammonium acetate at pH 6.8 and acetonitrile using gradient elution program and column temperature kept at 25 °C. Optimum resolution, consistent baseline separation of the studied compounds, was achieved by the previous condition (Fig. 1). The chromatographic conditions used allowed us to achieve the separation of colorants within 9 min.

Fig. 1
figure 1

HPLC chromatogram of 20 µl injection of laboratory prepared mixture of the five colorants, quantitation was achieved at 388 nm

A chromatogram was established with scanning in the wavelength range from 200 to 800 nm, continuously. The spectral data were very useful to confirm peak purity. The absorption maxima of the studied colorants were 426 nm, 482 nm, 508 nm, 517 nm, and 629 nm for E102, E110, E129, E122, and E133, respectively. Quantitation was achieved at 388 nm, where reasonable linearity ranges, LOD, and LOQ were achieved for all of the colorants studied. The average retention time ± standard deviation for E102, E110, E129, E122, and E133 were found to be 3.561 ± 0.02, 6.533 ± 0.04, 7.109 ± 0.05, 8.394 ± 0.07, and 8.864 ± 0.06 min, respectively, for seven replicates. The first to be eluted from the chromatographic column were the azo compounds, followed by non-azo compounds. The last synthetic colorant eluted was E133 which is derived from triphenyl methane and has an apolar character. For that, this compound interacted longer with the column and was the last to be eluted. The selectivity of the HPLC method was demonstrated in Table 2.

Table 2 System suitability results of the HPLC method developed for the analysis of E102, E110, E129, E122, and E133

Optimization of the UPLC-MS/MS Method

In the LC–ESI–MS/MS system, selection of the mobile phase composition is of high importance because it must offer an acceptable compromise between good chromatographic elution, separation, analytes ionization, and efficient desolvation of charged species in the MS detector. Satisfactory identification was performed with a mobile phase consisting of acetonitrile: 4 mM ammonium acetate (80:20 v/v) using isocratic elution (Fig. 2). The optimum flow rate was 0.3 mL min−1. These followed conditions, allowed us to quantify the studied colorants in 3 min.

Fig. 2
figure 2

UPLC-ESI–MS/MS chromatograms of 2 µl injection of the five colorants

Under these operating conditions, E102, E110, E129, E122, and E133 were negatively charged due to their chemicophysical properties. They undergo deprotonation due to the presence of acidic sites. For this reason, MS detection was performed in the negative ESI mode.

Structural Analyses of E102, E110, E129, E122, and E133 by UPLC-ESI–MS/MS

Upon observing the structural analyses of the studied colorants, E102 exhibited an (M-H)− ion at m/z 233.02 and eluted at 0.75 min, its MS/MS spectrum produced fingerprint fragment ions at m/z 210.91 and 197.58 (Fig. S2), E110 exhibited an (M-H)− ion at m/z 203.05 eluted at 0.79 min, its MS/MS spectrum produced fingerprint fragment ions at m/z 170.74, 155.78, and 106.68 (Fig. S3), E129 exhibited an (M-H)− ion at m/z 225.17 and eluted at 0.79 min, its MS/MS spectrum produced fingerprint fragment ions at m/z 235.92, 206.76, 200.03, 181.05, 171.75, and 135.98 (Fig. S4); E122 exhibited an (M-H)− ion at m/z 228.06 and eluted at 0.79 min, its MS/MS spectrum produced fingerprint fragment ions at m/z 220.96, 206.08, 169.98, and 79.69 (Fig. S5); and E133 exhibited an (M-H)− ion at m/z 373.32 and eluted at 0.78 min, its MS/MS spectrum produced fingerprint fragment ions at m/z 481.40, 333.33, and 169.99 (Fig. S6).

Validation of the Methods

Linearity

The linearity of the methods proposed was tested by evaluating the various concentrations of each compound. Nine concentrations were chosen in the 0.5–50 μg mL−1 range for the HPLC–DAD process, while concentrations in the range 0.01–5 μg mL−1 were used for the tested colorants in the UPLC-MS/MS range. Three injections were made for each concentration. The high value of the correlation coefficient was used to assess the calibration graphs’ linearities. The regression parameters for the methods obtained by the least square treatment of the results were shown in Table 3.

Table 3 Characteristic parameters for the regression equations of the proposed HPLC–DAD and UPLC-MS/MS methods for determination of E102, E122, E110, E129, and E133

Precision and Accuracy

Analysis of three concentration levels of working solutions of each compound on the same day determined the intra-day accuracy and also precision (each concentration was repeated three times). Inter-day accuracy and precision were measured on three consecutive days by evaluating the three concentration levels of working solutions. The acceptability of the data included accuracy stated as relative error (RE %) and precision stated as relative standard deviation (RSD %). Tables S1 and S2 summarized the results of intra-day and inter-day precision and accuracy.

The maximum measured relative standard deviation of the measurements was approximately 2.1% for UPLC-MS/MS and 2.6% for HPLC–DAD, suggesting the excellent precision of the analytical methods proposed at both repeatability and intermediate levels.

Limits of Detection and Quantification

According to ICH recommendations (ICH, 2005), the limit of detection (LOD) and the limit of quantification (LOQ) is determined as the ratio of 3.3 and 10 standard deviations of the blank (n = 9), respectively, and the slope of the calibration line. Table 3 presented the detection and quantitation limits calculated for E102, E110, E129, E122, and E133.

Selectivity

The selectivity of the methods was established by preparing five mixtures of the studied colorants within the linearity range at different concentrations. The mixtures were analyzed according to previously discussed procedures. Appropriate recoveries (Table S3) were generated, revealing the good selectivity of the methods proposed to concurrently analyze E102, E110, E129, E122, and E133.

Analytical Solution Stability

The analysis demonstrated that the standard colorants solutions were stable for about 3 h at room temperature, for 1 week if kept at 4 °C and for 1 month when kept in the freezer at − 20 °C.

Application to Real Samples

Analysis of Food Samples Using HPLC–DAD Method

The developed HPLC approach was efficiently applied to determine E102, E110, E129, E122, and E133 in sixty five food products which are consumed daily in Egypt especially by children, including carbonated fruit-flavored drinks, concentrated fruit-flavored soft drinks, chewing gums, candy smartiz, puddings, jellies, ice cream powders, and sugar confectionery. Upon reviewing literature for determination of these colorants in relatively similar matrices, the previous HPLC method (Al-Degs, 2009) for determination of only E129, E110, and E102 in commercial soft drinks showed long elution time of 10 min, while the reported method (Olgun, 2012), E102 and E110 and some other colorants were separated in beverages at very long retention time of 14 min and 19 min with the same limit of detection of our developed method and the previous method (Brazeau, 2018) needed a complicated sample pretreatment. This study is considered the first one to be conducted to determine the concentrations of the synthetic food colorants (E102, E110, E129, E122, and E133) in a huge amount of food products in Egypt and to compare the results with international limits with simple sample treatment, good sensitivity and short elution time.

The concentrations obtained by the developed HPLC method for the investigated colorants were shown in Table 4. The concentrations of colorants varied from 0.0252 mg kg−1 (sample D61) to 213.696 mg kg−1 (sample D53). A strange fact is that some manufacturers report that their product contains a certain colorant while a different colorant was detected and quantified by our method (sample A3). Furthermore, some products contained excess colorants which were not labeled (samples A2, A17, A20, A21, A25, A28, B30, B42, B43, C48, C50, D53, D57, D58, and D61). Some colorants were labeled but not identified as in the samples A6, A14, A17, A24, B30, B34, C45, C51, D52, D64, and D65.

Table 4 Concentrations of the five synthetic colorants among sixty five real food samples of four categories using the HPLC–DAD method

Analysis of Some Selected Samples Using UPLC-MS/MS Method

Products which contain very high concentrations of colorants above ADI levels were investigated and characterized by UPLC-ESI–MS/MS technique. Ten food samples (A5, A11, A13, A19, B31, B40, B41, B42, B43, and D53) were selected. Table S4 summarized the results of the ten samples and Fig. 3 showed five food products containing high concentrations of synthetic colorants. According to FDA, ADI of the studied colorants were used to calculate the maximum allowed amount for children weighed 15–25 kg and adults weighed 60–70 kg per day. The data were given in Table S5.

Fig. 3
figure 3

a Examples of typical chromatograms: (1) E102 & E110 in sample B42. (2) E102 & E110 in sample B41. (3) E102 in sample A19. (4) E122 in sample D53. (5) E102 in sample B40; b identified colorant (E129) in sample B42

The sample D53 contained the highest concentration among the others, definitely 199.6 mg/Kg of E122 colorant which is not allowed by FDA due to its harmful effects on human health as it has an adverse effect on activity and attention in children. Also, samples B40, B41, B42, and A19 acquired concentrations of colorants above the legal limit. Also in sample B42, the manufacturer reported that the product containing only E102 and E110, and the analysis confirmed the presence of one more synthetic colorant, E129 (Fig. 3). This revealed that our study is suitable for confirmation of the identity and quantity of colorants in foods.

These results have shown that there is a strong need to track the concentrations of synthetic colorants used in food products in order to protect public health from the significant adverse effects of such chemicals and to raise awareness among both consumers and policy makers.

Conclusion

At present, there are many food colorants added to food products in order to attract consumers especially children. Some individuals are sensitive to such food colorants; the names of the colors present in the food product must be the same as those on the food product label and the quantity of colorants must be specified in order to ensure food safety. For that, it is necessary to provide for a simplified procedure that allow the determination of these colorants. The current study provided a RP-HPLC–DAD approach for the identification and determination of food colorants definitely Tartrazine E102, Allura Red E129,Sunset Yellow E110, Brilliant Blue E133, and Carmoisine E122 in a set of 65 Egyptian food products from different producers, in which they were well separated in only 9 min with simple sample preparation procedures. In addition a UPLC-ESI–MS/MS approach was developed and utilized as highly precise, sensitive confirmatory method, which could be applied successfully to suspicious marketed products.