Abstract
Voltage Sweep Ion Mobility Spectrometry (VSIMS) has been applied to complex samples using electrospray ionization (ESI). The usable range of VSIMS has been extended from that obtained in previous studies where only volatile compounds were investigated. Using ESI, VSIMS was evaluated with compounds with reduced mobility values as low as 0.3 V2cm−1 s−1. The primary advantage of VSIMS is to enable a drift time ion mobility spectrometer (DTIMS) to detect both fast and slow moving ions at optimal resolving power, thus improving the peak capacity. In this work ESI-VSIMS was applied to a series of small peptides and drugs spanning a large range of reduced mobility values in order to demonstrate ESI-VSIMS to separation. To demonstrate improved peak capacity of IMS with voltage scan operation, oligomers of silicone oil provided a series of evenly-spaced peaks, ranging in reduced mobility values from 0.85 to 0.3 V2cm−1 s−1. The peak capacity of 61 for a standard IMS was improved to 102 when voltage sweep operation was employed. In addition, VSIMS increased the average resolving power of the DTIMS from 66 to 106 for silicone oil.
Similar content being viewed by others
References
Eiceman GA, Karpas Z (1994) Ion Mobility Spectrometry. FL, CRC Press, Inc., Boca Raton
Ewing RG, Atkinson DA, Eiceman GA, Ewing GJ (2001) A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds. Talanta 54:515–529
Daum KA, Atkinson DA, Ewing RG (2002) The role of oxygen in the formation of TNT product ions in ion mobility spectrometry. Int J for Mass Spec 214:257–267
Eiceman GA, Nazarov EG, Stone JA (2003) Chemical standards in ion mobility spectrometry. Anal Chim Acta 493:185–194
Eiceman GA, Stone JA (2004) Ion mobility spectrometers in national defense. Anal Chem 76(21):390, A-397 A
Kanu AB, Hill HH (2007) Identity confirmation of drugs and explosives in ion mobility spectrometry using a secondary drift gas. Talanta 73(4):692–699
Babis JS, Sperline RP, Knigh AK, Jones DA, Gresham CA, Denton MB (2009) Performance evaluation of a miniature ion mobility spectrometer drift cell for application in hand-held explosives detection ion mobility spectrometers. Anal Bioanal Chem 395:411–419
Clowers BH (2005). Separation of gas phase isomers using Ion mobility and mass spectrometry. PhD Thesis, Washington State University
Dwivedi P, Bendiak B, Clowers B, Hill HHJ (2007) Rapid resolution of carbohydrate isomers by electrospray ionization ambient pressure Ion mobility spectrometry-time-of-flight mass spectrometry (ESI-APIMS-TOFMS). J Amer Soc For Mass Spec 18:1163–1175
Siems WF, Wu C, Tarver EE, Hill HHJ (1994) Measuring the resolving power of ion mobility spectrometers. Anal Chem 66:4195–4201
Davis EJ, Dwivedi P, Tam M, Siems WF, Hill HH (2009) High-pressure Ion mobility spectrometry. Anal Chem 81:3270–3275
Baether W, Zimmermann S, Gunzer F (2010) Investigation of the influence of voltage parameters on decay times in an ion mobility spectrometer with a pulsed non-radioactive electron source. Int J Ion Mob Spec 13(3–4):95–101
Davis EJ, Williams MD, Siems WF, Hill HH (2011) Voltage sweep Ion mobility spectrometry. Anal Chem 83(4):1260–1267
Langejuergen J, Cochems P, Zimmermann S (2012) Results of a transient simulation of a drift tube ion mobility spectrometer considering charge repulsion, ion loss at metallic surfaces, and ion generation. Int J Ion Mob Spec 15(4):247–255
Kanu AB, Gribb MM, Hill HHJ (2008) Determining optimal resolving power for ambient pressure Ion mobility spectrometry (APIMS). Anal Chem 80:6610–6619
Nogare SD, Bennett CE (1958) Programmed temperature gas chromatography. Anal Chem 30(6):1157–1158
Clemmer DE, Hudgins RR, Jarrold MF (1995) Naked protein conformations: cytochrome c in the gas phase. J of the Amer Chem Soc 117(40):10141–10142
Stone E, Gillig KJ, Ruotolo B, Fuhrer K, Gonin M, Schults A, Russell DH (2001) Surface-induced dissociation on a MALDI-Ion mobility-orthogonal time-of-flight mass spectrometer: sequencing peptides from an in-solution protein digest. Anal Chem 73:2233–2238
Pringle SD, Giles K, Wildgoose JL, Williams JP, Slade SE, Thalassinos K, Bateman RH, Bowers MT, Scrivens JH (2007) An investigation of the mobility separation of some peptide and protein ions using a new hybrid quadrupole/travelling wave IMS/oa-TOF instrument. Int J for Mass Spec 261:1–12
Scarff CA, Thalassinos K, Hilton GR, Scrivens JH (2008) Travelling wave ion mobility mass spectrometry studies of protein structure: biological significance and comparison with X-ray crystallography and nuclear magnetic resonance spectroscopy measurements. Rapid Comm In Mass Spec 22:297–3304
Wu C, Siems WF, Asbury GR, Hill HH (1998) Electrospray ionization high-resolution Ion mobility spectrometry-mass spectrometry. Anal Chem 7:4929–4938
Wu C, Siems WF, Hill HHJ (2000) Secondary electrospray ionization Ion mobility spectrometry/mass spectrometry of illicit drugs. Anal Chem 72:396–403
Davis EJ, Clowers BH, Siems WF, Hill HHJ (2011) Comprehensive software suite for the operation, maintenance, and evaluation of an ion mobility spectrometer. Int J Ion Mob Spec 14:117–124
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Davis, E.J., Grows, K.F., Siems, W.F. et al. Electrospray ionization-voltage sweep-Ion mobility spectrometry for biomolecules and complex samples. Int. J. Ion Mobil. Spec. 17, 147–156 (2014). https://doi.org/10.1007/s12127-014-0155-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12127-014-0155-7