Abstract
The implementation of hand-held ion mobility spectrometers (IMS) requires the development and evaluation of miniature drift cells providing high sensitivity while maintaining reasonable resolution. This manuscript describes the construction of a miniature IMS designed for such an application and its characterization by evaluation of the detection limits and resolution of the system with seven explosive compounds including trinitrotoluene (TNT), cyclotrimethylenetrinitramine (RDX), pentaerythritol tetranitrate (PETN), 2,4,6-trinitrophenyl-N-methylnitramine (Tetryl), nitroglycerin (NG), 2,4-dinitrotoluene (2,4 DNT), and 2,6-dinitrotoluene (2,6 DNT).
Similar content being viewed by others
References
Baumbach JI, Eiceman GA (1999) Appl Spectr 53:338A–355A
Miller RA, Eiceman GA, Nazarov EG, King AT (2000) Sens Act B-Chem 67(3):300–306
Teepe M, Kang WJ, Nayer A, Baumbach JI, Schmidt H (2000) Int J Ion Mobility Spectrom 4:173–176
Sizov FF, Derkach YP, Kononenko YG, Reva VP (1999) Readout device processing electronics for IR linear and focal plane arrays
Denton MB (2001) Abstracts of Papers, 222nd ACS National Meeting, Chicago, IL, United States, pp 26-30, August 2001, ANYL-170
2006 Final Annual Report to the United States Department of Energy, Subcontracts A0334-30141 and A0344677767
United States Patent, 7403065
Knight AK, Sperline RP, Hieftje GM, Young E, Barinaga CJ, Koppenaal DW, Denton MB (2002) Intern J Mass Spectr 215:131–139
Barnes JHI, Sperline R, Denton MB, Barinaga CJ, Koppenaal D, Young ET, Hieftje GM (2002) Anal Chem 74:5327–5332
Schilling GD, Andrade FJ, Barnes JH, Sperline RP, Denton MB, Barinaga CJ, Koppenaal DW, Hieftje GM (2006) Anal Chem 78:4319–4325
Barnes JHI, Schilling GD, Hieftje GM, Sperline RP, Denton MB, Barinaga CJ, Koppenaal DW (2004) J Amer Soc Mass Spectr 15:769–776
Barnes JHI, Schilling GD, Sperline R, Denton MB, Young ET, Barinaga CJ, Koppenaal DW, Hieftje GM (2004) Anal Chem 76:2531–2536
Sperline RP, Knight AK, Gresham CA, Koppenaal DW, Hieftje GM, Denton MB (2005) Appl Spectr 59:1315–1323
Tyndall AM, Powell CF (1930) Proc Roy Soc London A129:162–180
Zverev AI (1967) Handbook of filter synthesis. Wiley, New York, p 71
LabView Version 7.1, National Instruments, Inc., FIR Windowed Filter.VI, 7.1 ed., 2006
Bruschini C (2001) Subsurf Sens Technol Appl 2:299–336
Ewing RG, Miller CJ (2001) Field Anal Chem Tech 5(5):215–221
Acknowledgments
The authors would like to acknowledge Gene Atlas and Kim Johnson of Imager Laboratories for turning concepts into functional devices, and the Department of Energy, Subcontracts A0334-30141 and A0344677767, for support of this work. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Babis, J.S., Sperline, R.P., Knight, A.K. et al. Performance evaluation of a miniature ion mobility spectrometer drift cell for application in hand-held explosives detection ion mobility spectrometers. Anal Bioanal Chem 395, 411–419 (2009). https://doi.org/10.1007/s00216-009-2818-5
Received:
Revised:
Accepted:
Published:
Issue Date: