Abstract
Monte Carlo N-particle (MCNP) code has been used to simulate the transport of gamma photon rays of different energies (22, 31, 59.5 and 81 keV) to estimate the iron content in solutions. In this study, MCNP simulation results are compared with experiment and XCOM theoretical data. The simulation shows that the obtained results are in good agreement with experimental data, and better than the theoretical XCOM values. The study indicates that MCNP simulation is an excellent tool to estimate the iron concentration in the blood samples. The MCNP code can also be utilized to estimate other trace elements in the blood samples.
Similar content being viewed by others
References
M Esfandiari, S P Shirmardi, and M E Medhat, Radiat. Phys. Chem. 99, 30 (2014)
Kubala-Kukus, J Braziewicz, and M Pajek, Spectrochim. Acta Part B 59, 1283 (2004)
R H Filby, Pure Appl. Chem. 67(11), 1929 (1995)
N F Soliman, A Sroor, L S Ashmawy, N Walley El-Dine and T El-Mohamed, Na, Al, K, Mn, Mg, Br, Ca, and Cl Concentration values in the whole blood samples of human cancer using short time neutron irradiation facility of ET-RR-2, Proceedings of the 7th Conference on Nuclear and Particle Physics, 11–15 November 2009 (Sharm El-Sheikh, Egypt)
E A Hernández-Caraballo and L M Marcó-Parra, Spectrochim. Acta Part B 58, 2205 (2003)
N R Ananth, Trace element estimation – Methods & clinical context, OJHAS, ISSN 0972-5997, Vol. 49(1), 1–9, Available at http://www.ojhas.org/issue13/2005-1-1.htm (2005)
International commission on Radiation Protection, Tissue Substitutes in Radiation Dosimetry and Measurement (Report 44), 910 Woodmont Avenue, Bethesda, Maryland 20814, USA 1989
S Pang, S Liu, and X Su, Talanta 118, 118 (2014)
H Ranganathan and N Gunasekaran, IEEE Trans. Inf. Technol. Biomed. 10, 657 (2006)
M E Medhat, J. Radioanal. Nucl. Chem. 300, 437 (2014)
J F Briesmeister, MCNPTM – A General Monte Carlo N-Particle Transport Code Version 4C, RSICC Computer code collection, ccc700, Oak Ridge National Laboratory (2000)
M J Berger, J H Hubbell, S M Seltzer, J Chang, J S Coursey, R Sukumar, D S Zucker and K Olsen, XCOM: Photon cross sections database, NIST standard reference database (XGAM), available at http://www.nist.gov/pml/data/ xcom/index.cfm (2010)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
MEDHAT, M.E., SHIRMARDI, S.P. & SINGH, V.P. Monte Carlo simulation for the estimation of iron in human whole blood and comparison with experimental data. Pramana - J Phys 88, 49 (2017). https://doi.org/10.1007/s12043-016-1344-1
Received:
Revised:
Accepted:
Published:
DOI: https://doi.org/10.1007/s12043-016-1344-1