Skip to main content
Log in

Removal of eye blink artifacts from EEG signal using morphological modeling and orthogonal projection

  • Original Paper
  • Published:
Signal, Image and Video Processing Aims and scope Submit manuscript

Abstract

The presence of artifacts in the EEG signals can cause a misunderstanding of the sought neurophysiological phenomena. In particular, the eye blink artifacts frequently contaminate the EEG and deteriorate its quality. Unfortunately, removing this artifact can lose useful information. The most popular approach in this field uses the independent component analysis to decompose the signal into different independent components and then eliminate those that are related to the artifact. Despite its reputation, this approach is computationally intensive, requires an acquisition from large number of channels and can alter the original EEG signal. In this paper, we propose a new method for blink artifact reduction. Several reference signals representing the eye blink are created then used in an orthogonal projection in order to cancel the artifact. The results of experiments, using 54 datasets from 27 subjects, show that the proposed method significantly outperformed the standard ADJUST, MARA and SASICA methods in removing the artifacts while preserving the pure EEG signals.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  1. Fatourechi, M., Bashashati, A., Ward, R.K., Birch, G.E.: EMG and EOG artifacts in brain computer interface systems: a survey. Clinic. Neurophysiol. 118, 480–494 (2007)

    Article  Google Scholar 

  2. Gu, Y., Cleeren, E., Dan, J., Claes, K., Van Paesschen, W., Van Huffel, S., Hunyadi, B.: comparison between scalp EEG and behind-the-ear EEG for development of a wearable seizure detection system for patients with focal epilepsy. Sensors. 8, 1–17 (2017)

    Google Scholar 

  3. Jadhav, P.N., Shanamugan, D., Chourasia, A., Ghole, A.R., Acharyya, A., Naik, G.: automated detection and correction of eye blink and muscular artefacts in EEG signal for analysis of autism spectrum disorder. Annual international conference of the IEEE engineering in medicine and biology society (EMBC). Chicago IL USA, 1881-1884 (2014)

  4. Felinger, A.: Data handling in science and technology. Elsevier 21, 143–181 (1998)

    Google Scholar 

  5. Uriguen, J.A., Garcia-Zapirain, B.: EEG artifact removal – state-of-the-art and guidelines. J. Neural Eng. 12, 1–23 (2015)

    Article  Google Scholar 

  6. Jiang, X., Bian, G.B., Tian, Z.: removal of artifacts from EEG signals: a review. Sensors. 19, 1–18 (2019)

    Article  Google Scholar 

  7. Romero, S., Mañanas, M.A., Barbanoj, M.J.: Ocular reduction in EEG signals based on adaptive filtering, regression and blind source separation. Annal. Biomed. Eng. 37, 176–191 (2009)

    Article  Google Scholar 

  8. Kong, W., Zhou, Z., Hu, S., Zhang, J., Babiloni, F., Dai, G.: Automatic and direct identification of blink components from scalp EEG. Sensors. 13, 10783–10801 (2013)

    Article  Google Scholar 

  9. Klados, M.A., Papadelis, C., Braun, C., Bamidis, P.D.: REG-ICA: a hybrid methodology combining blind source separation and regression techniques for the rejection of ocular artifacts. Biomed. Signal Process. control 6, 291–300 (2011)

    Article  Google Scholar 

  10. Naghsh, E., Sabahi, M.F., Beheshti, S.: Spatial analysis of EEG signals for Parkinson’s disease stage detection. Signal Image Video Process. 14, 397–405 (2020)

    Article  Google Scholar 

  11. Mammone, N., Morabito, F.C.: Enhanced automatic wavelet independent component analysis for electroencephalographic artifact removal. Entropy 16, 6553–6572 (2014)

    Article  Google Scholar 

  12. Zeng, K., Chen, D., Ouyang, G., Wang, L., Liu, X., Li, X.: An EEMD-ICA approach to enhancing artifact rejection for noisy multivariate neural data. IEEE Transactions Neural Syst. Rehabil. Eng. 24, 630–638 (2016)

    Article  Google Scholar 

  13. Mahajan, R., Morshed, B.I.: unsupervised eye blink artifact denoising of EEG data with modified multiscale sample entropy, kurtosis, and wavelet-ICA. IEEE J Biomed. Health Inform. 19, 158–165 (2015)

    Article  Google Scholar 

  14. Val-Calvo, M., Álvarez-Sánchez, J.R., Ferrández-Vicente, J.M., Fernández, E.: Optimization of real-time EEG artifact removal and emotion estimation for human-robot interaction applications. Front. Comput. Neurosci. 13, 1–13 (2019)

    Article  Google Scholar 

  15. Wang, G., Teng, C., Li, K., Zhang, Z., Yan, X.: The removal of EOG artifacts from EEG signals using independent component analysis and multivariate empirical mode decomposition. IEEE J Biomed. Health inform. 20, 1301–1308 (2016)

    Article  Google Scholar 

  16. Yadav, A., Choudhry, M.S.: a new approach for ocular artifact removal from EEG signal using EEMD and SCICA. Cogent Engineering. 7, 1813146 (2020)

    Article  Google Scholar 

  17. Mognon, A., Jovicich, J., Bruzzone, L., Buiatti, M.: ADJUST: an automatic EEG artifact detector based on the joint use of spatial and temporal features. Psychophysiology 48, 229–240 (2011)

    Article  Google Scholar 

  18. Delorme, A., Makeig, S.: EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics. J Neurosci. Methods 134, 9–21 (2004)

    Article  Google Scholar 

  19. Debnath, R., Buzzell, G.A., Morales, S., Bowers, M.E., Leach, S.C., Fox, N.A.: the maryland analysis of developmental EEG (MADE) pipeline. Psychophysiology. 57 (2020)

  20. Leach, S.C., Morales, S., Bowers, M.E., Buzzell, G.A., Debnath, R., Beall, D., Fox, N.A.: adjusting ADJUST: optimizing the ADJUST algorithm for pediatric data using geodesic nets. Psychophysiology. 57, 1–15 (2020)

    Article  Google Scholar 

  21. Winkler, I., Haufe, S., Tangermann, M.: Automatic classiication of artifactual ICA-components for artifact removal in EEG Signals. Behav Brain Funct. 7, 1–15 (2011)

    Article  Google Scholar 

  22. Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., Tangermann, M.: Robust artifactual independent component classiication for BCI practitioners. J. Neural Eng. 11, 1–10 (2014)

    Article  Google Scholar 

  23. Pedroni, A., Bahreini, A., Langer, N.: Automagic: standardized preprocessing of big EEG data. NeuroImage. 200, 460–473 (2019)

    Article  Google Scholar 

  24. Nolan, H., Whelan, R., Reilly, R.B.: FASTER: fully automated statistical thresholding for EEG artifact rejection. J. Neurosci. Methods 192, 152–162 (2010)

    Article  Google Scholar 

  25. Chaumon, M., Bishop, D.V.M., Busch, N.A.: A practical guide to the selection of independent components of the electroencephalogram for artifact correction. J. Neurosci. Methods. 250, 47–63 (2015)

    Article  Google Scholar 

  26. Burger, C., Van Den Heever, D.J.: Removal of EOG artefacts by combining wavelet neural network and independent component analysis. Biomed. Signal Process. Control 15, 67–79 (2015)

    Article  Google Scholar 

  27. Wang, Z., Xu, P., Liu, T., Tian, Y., Lei, X., Yao, D.: Robust removal of ocular artifacts by combining independent component analysis and system identification. Biomed. Signal Process. Control 10, 250–259 (2014)

    Article  Google Scholar 

  28. Zhang, S., McIntosh, J., Shabah, M.S.: SHNeo P, Huang Z, McNaughton, N (2017) Removing eye blink artefacts from EEG-A single-channel physiology-based method. J. Neurosci. Methods 219, 213–220 (2017)

    Article  Google Scholar 

  29. Kladosa, M.A., Bamidisb, D.P.: A semi-simulated EEG/EOG dataset for the comparison of EOG artifact rejection techniques. Data Brief. 8, 1004–1006 (2016)

    Article  Google Scholar 

  30. Elbert, T., Lutzenberger, W., Rockstroh, B., Birbaumer, N.: removal of ocular artifacts from the EEG–a biophysical approach to the EOG. Electroencephalograph Clinic. Neurophysiol. 60, 455–463 (1985)

    Article  Google Scholar 

  31. Issa, M.F., Juhasz, Z.: improved EOG artifact removal using wavelet enhanced independent component analysis. Brain Sci. 9, 1–22 (2019)

    Article  Google Scholar 

Download references

Acknowledgments

This work is carried out under the MOBIDOC scheme, funded by the European Union (EU) through the EMORI program and managed by the National Agency for the Promotion of Scientific Research (ANPR).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Omar Trigui.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Trigui, O., Daoud, S., Ghorbel, M. et al. Removal of eye blink artifacts from EEG signal using morphological modeling and orthogonal projection. SIViP 16, 19–27 (2022). https://doi.org/10.1007/s11760-021-01947-w

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11760-021-01947-w

Keywords

Navigation