Abstract
Particles of Zn powder have been studied to show that high-quality scanning electron microscope (SEM) and transmission electron microscope (TEM) specimens can be rapidly produced from a site-specific region on a chosen particle by the focused ion beam (FIB) lift-out technique. A TEM specimen approximately 20-µm long by 5-µm wide was milled to electron transparency, extracted from the bulk particle, and micromanipulated onto a carbon coated copper mesh TEM grid. Using the FIB lift-out method, we were able to prepare a site-specific TEM specimen from a difficult material in under 3 hours. The TEM analysis of the lift-out specimen revealed a large amount of thin area free from characteristic signs of damage that may be observed as a result of conventional argon ion milling. The overall microstructure of the specimen prepared by the FIB lift-out method was consistent with samples prepared by conventional metallographic methods. A grain size of ∼10 to 20 µm was observed in all specimens by both TEM and SEM analysis. Light optical microscopy revealed the presence of internal voids in ∼10 to 20 pct of all particles. The SEM analysis showed the voids to extend over ∼70 pct of the particle volume in some cases.
Similar content being viewed by others
References
Randall M. German: Powder Metallurgy Science, 2nd ed., Metal Powder Industries Federation, Princeton, NJ, 1994, pp. 16–25.
Donald G. White: Des. News, 1996, vol. 51, p. 102.
Donald G. White: Mach. Des., 1994, vol. 66.
Thomas B. Gurganus: Adv. Mater. Processes, 1995, vol. 148, pp. 57–59.
David T. Gethen, Viet D. Tran, and Roland W. Lewis: Int. J. Powder Metall., 1994, vol. 30, pp. 385–98.
Animesh Bose: Int. J. Powder Metall., 1995, vol. 47, pp. 26–30.
Reginald L. Eadie and Xiolin Chen: Int. J. Powder Metall., 1996, No. 3, pp. 265–75.
David B. Williams and Barry Carter: Transmission Electron Microscopy, Plenum Press, New York, NY, 1996, pp. 163–64.
Manfred Von Heimendahl: Electron Microscopy of Materials, An Introduction, Academic Press, Inc., San Diego, CA, 1980, pp. 89–91.
J.A. Yater and M.O. Thompson: J. Vac. Sci. Technol. B, 1992, vol. 10 (1), pp. 183–86.
C.E. Sanborn and S.A. Myers: Materials Research Society Symp. on Specimen Preparation for Transmission Electron Microscopy of Materials—III, American Institute of Physics, College Park, MD, 1992, vol. 254, pp. 239–48.
M.H.F. Overwijk, F.C. van den Heuvel, and C.W.T. Bule-Lieuwma: J. Vac. Sci. Technol. B, 1993, vol. 11(6), pp. 2021–24.
M. Tartuani, Y. Takai, R. Shimizu, K. Uda, and H. Takahashi: Tech. Rep. Osaka Univ., 1993, vol. 43 (2143), pp. 167–73.
M.L. Thayer: ISTFA ’93, Proc. 19th Int. Symp. on Testing Failure Analysis, ASM International, Materials Park, OH, 1993, pp. 425–29.
T. Ishitani, H. Tsuboi, T. Yaguchi, and H. Koike: J. Electron Microsc., 1994, vol. 43, pp. 322–26.
F.A. Stevie, T.C. Shane, P.M. Kahora, R. Hull, D. Bahnck, V.C. Kanna, and E. David: Surf. Interface Anal., 1995, vol. 23, pp. 61–68.
Y. Kitano, Y. Fujikawa, T. Kamino, T. Yaguchi, and H. Saka: J. Electron Microsc., 1995, vol. 44, pp. 410–13.
L.A. Giannuzzi, J.L. Drown, S.R. Brown, R.B. Irwin, and F.A. Stevie: Microsc. Res. Technol, Wiley-Liss, Inc., vol. 41, 1998, pp. 285–90.
L.A. Giannuzzi, J.L. Drown, S.R. Brown, and R.B. Irwin, and F.A. Stevie: Workshop on Specimen preparation for TEM of Materials IV, Materials Research Society Symposia Proceedings, Materials Research Society, Pittsburgh, PA, 1997, pp. 19–27.
R. Noone: Euro ASIC ’92, Proc. Euro ASIC 92, 1992, IEEE Service Center, Piscataway, NJ, pp. 414–15.
H. Mendez, S. Morris, S. Tatti, N. Dickson, and R.E. Pyle: SPIE Proc. Microelectronics Manufacturing and Reliability, 1992, vol. 1802, pp. 126–33.
F.C. van den Heuvel, M.H.F. Overwijk, E.M. Fleuren, H. Laisina, and K.J. Sauer: Microelectron. Eng., 1993, vol. 21, pp. 209–12.
A.B. Soto and S.L. Riley: ISTFA ’93, Proc. 19th Int. Symp. on Testing Failure Analysis, ASM International, Materials Park, OH, 1993, pp. 419–24.
K. Van Doorselaer, M. Van den Reeck, L. Van den Bempt, R. Young, and J. Whitney: ISTFA ’93, Proc. 19th Int. Symp. on Testing Failure Analysis, ASM International, Materials Park, OH, 1993, pp. 405–15.
K. Van Doorselaer and L. Van den Bempt: ISTFA ’94, Proc. 20th Int. Symp. on Testing Failure Analysis, ASM International, Materials Park, OH, 1994, pp. 397–405.
S.X. Li, D. Lee, and S. Leung: ISTFA ’94, Proc. 20th Int. Symp. on Testing Failure Analysis, ASM International, Materials Park, OH, 1994, pp. 415–19.
J.M. Chabala, R. Levi-Setti, and Y.L. Wang: J. Vasc. Sci Technol. B, 1988 vol. 6 (3), pp. 910–14.
D.E. Newbury: Microbeam Analysis, San Francisco Press, Inc., San Francisco, CA, 1988, pp. 93–101.
C.H. Chu, Y.F. Hseih, L.R. Harriot, and H.H. Wade: J. Vac. Sci Technol. B, 1991; vol. 9 (6), pp. 3451–55.
M-Bond 600 Adhesive Manufacturer’s Literature, M-Line Accessories, Measurements Group, Inc., Raleigh, NC.
Randall M. German: Powder Metallurgy Science, 2nd ed., Metal Powder Industries Federation, Princeton, NJ, 1994, pp. 100–06.
T. Ishitani, K. Umemura, Y. Kawanami, and T. Ohnishi: J. Electrochem. Soc., 1989, vol. 136 (11), pp. 3502–05.
M.H.F. Overwijk and F.C. van den Heuvel: Nucl. Instrum. Methods Phys. Res., 1993, sect. B, vol. 80, pp. 1324–27.
H. Yamaguchi, A. Shimase, S. Haraaichi, and T. Miyauchi: J. Vac. Sci. Technol. B, 1985, vol. 3, pp. 71–74.
FEI Focused Ion Beam Application Note, High Aspect Ratio Hole Drilling Using FIB Enhanced Etch Process, 1993.
J.F. Walker: Unpublished research.
L.A. Giannuzzi: Ph.D. Thesis, The Pennsylvania State University, University Park, PA, 1992.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Prenitzer, B.I., Giannuzzi, L.A., Newman, K. et al. Transmission electron microscope specimen preparation of Zn powders using the focused ion beam lift-out technique. Metall Mater Trans A 29, 2399–2406 (1998). https://doi.org/10.1007/s11661-998-0116-z
Received:
Issue Date:
DOI: https://doi.org/10.1007/s11661-998-0116-z