Abstract
During the last few years, various flow-based separation/preconcentration methodologies have gained pertinent novel advances and exhibited powerful capability in the field of sample pretreatment and their hyphenation with detection by atomic spectrometry. The present mini-review presents and discusses the progress of flow-based sample processing approaches commonly used for the assay of trace elemental species with detection by atomic spectrometry, including preliminary sample pretreatment, solid phase extraction (including solid phase microextraction), liquid-liquid extraction, vapor generation and dialysis techniques. Special emphasis has been paid on the novel applications and analytical procedures hyphenated with atomic spectrometry. The future perspectives of flow-based sample pretreatment protocols in the determination of trace elements and their speciation are also discussed.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Clough R, Drennan-Harris L R, Harrington C F, et al. Atomic spectrometry update. Elemental speciation. J Anal At Spectrom, 2012, 27: 1185–1224
Evans E H, Palmer C D, Smith C M M. Atomic spectrometry update. Advances in atomic spectrometry and related techniques. J Anal At Spectrom, 2012, 27: 909–927
Yu Y L, Jiang Y, Chen M L, et al. Lab-on-valve in the miniaturization of analytical systems and sample processing for metal analysis. Trends Anal Chem, 2011, 30: 1649–1658
Taylor A, Branch S, Day M P, et al. Atomic spectrometry update. Clinical and biological materials, foods and beverages. J Anal At Spectrom, 2011, 26: 653–692
Sakan S, Dordevic D, Devic G, et al. A study of trace element contamination in river sediments in Serbia using microwave-assisted aqua regia digestion and multivariate statistical analysis. Microchem J, 2011, 99: 492–502
Zachariadis G A, Spanou E A. Microwave-assisted acid extraction methodology for trace elements determination in mastic gum of pistacia lentiscus using inductively coupled plasma atomic emission spectrometry. Phytochem Anal, 2011, 22: 31–35
Mukhtar A, Limbeck A. On-line determination of water-soluble zinc in airborne particulate matter using a dynamic extraction procedure coupled to flame atomic absorption spectrometry. J Anal At Spectrom, 2010, 25: 1056–1062
Amberger M A, Broekaert J A C. Direct multielement determination of trace elements in boron carbide powders by slurry sampling ETV-ICP-OES. J Anal At Spectrom, 2010, 25: 1308–1315
Hatje V, Macedo S M, de Jesus R M, et al. Inorganic As speciation and bioavailability in estuarine sediments of Todos os Santos Bay, BA, Brazil. Mar Pollut Bull, 2010, 60: 2225–2232
Scaccia S, Mecozzi R. Trace Cd, Co, and Pb elements distribution during Sulcis coal pyrolysis: GFAAS determination with slurry sampling technique. Microchem J, 2012, 100: 48–54
Cunha F A S, Sousa R A, Harding D P, et al. Automatic microemulsion preparation for metals determination in fuel samples using a flow-batch analyzer and graphite furnace atomic absorption spectrometry. Anal Chim Acta, 2012, 727: 34–40
Tavakkoli N, Habibollahi S, Tehrani A S. Modified activated carbon as solid phase extraction adsorbent for the preconcentration and determination of trace As(III) in environmental samples by graphite furnace atomic absorption spectrometry. Chin J Chem, 2012, 30: 665–669
Tian H, Chang X, Hu Z, et al. Activated carbon modified with 4-(8-hydroxyquinoline-azo) benzamidine for selective solid-phase extraction and preconcentration of trace lead from environmental samples. Microchim Acta, 2010, 171: 225–232
Wang Q, Chang X, Hu Z, et al. Preconcentration of erbium(III) ions from environmental samples using activated carbon modified with benzoyl hydrazine. Microchim Acta, 2011, 172: 395–402
Tu Z, Lu S, Chang X, et al. Selective solid-phase extraction and separation of trace gold, palladium and platinum using activated carbon modified with ethyl-3-(2-aminoethylamino)-2-chlorobut-2-enoate. Microchim Acta, 2011, 173: 231–239
Ayata S, Bozkurt S S, Ocakoglu K. Separation and preconcentration of Pb(II) using ionic liquid-modified silica and its determination by flame atomic absorption spectrometry. Talanta, 2011, 84: 212–215
Bagheri A, Behbahani M, Amini M M, et al. Simultaneous separation and determination of trace amounts of Cd(II) and Cu(II) in environmental samples using novel diphenylcarbazide modified nanoporous silica. Talanta, 2012, 89: 455–461
Kim M L, Tudino M B. Evaluation of performance of three different hybrid mesoporous solids based on silica for preconcentration purposes in analytical chemistry: From the study of sorption features to the determination of elements of group IB. Talanta, 2010, 82: 923–930
Rastegarzadeh S, Pourreza N, Kiasat A R, et al. Selective solid phase extraction of palladium by adsorption of its 5(p-dimethylaminoben-zylidene)rhodanine complex on silica-PEG as a new adsorbent. Microchim Acta, 2010, 170: 135–140
Trujillo S I, Alonso V E, Cordero S M T, et al. On-line solid-phase chelation for the determination of six metals in sea-water by inductively coupled plasma mass spectrometry. J Anal At Spectrom, 2010, 25: 1063–1071
Sharma R K, Pandey A, Gulati S, et al. An optimized procedure for preconcentration, determination and on-line recovery of palladium using highly selective diphenyldiketone-monothiosemicarbazone modified silica gel. J Hazard Mater, 2012, 209: 285–292
Soleimani M, Mahmodi M S, Morsali A, et al. Using a new ligand for solid phase extraction of mercury. J Hazard Mater, 2011, 189: 371–376
Wang Z, Fang D M, Li Q, et al. Modified mesoporous silica materials for on-line separation and preconcentration of hexavalent chromium using a microcolumn coupled with flame atomic absorption spectrometry. Anal Chim Acta, 2012, 725: 81–86
Yu H M, Song H, Chen M L. Dithizone immobilized silica gel on-line preconcentration of trace copper with detection by flame atomic absorption spectrometry. Talanta, 2011, 85: 625–630
Dindar M H, Fathi S A M, Yaftian M R, et al. Solid phase extraction of copper(II) ions using C18-silica disks modified by oxime ligands. J Hazard Mater, 2010, 179: 289–294
Fathi S A M, Rostamkhani S, Yaftian M R. Determination of trace amounts of copper in water samples by flame atomic absorption spectrometry after preconcentration on octadecyl-bonded silica membranes modified by a Di-Schiff base ligand. J Anal Chem, 2010, 65: 614–619
Rofouei M K, Sabouri A, Ahmadalinezhad A, et al. Solid phase extraction of ultra traces mercury (II) using octadecyl silica membrane disks modified by 1,3-bis(2-ethoxyphenyl)triazene (EPT) ligand and determination by cold vapor atomic absorption spectrometry. J Hazard Mater, 2011, 192: 1358–1363
AlSuhaimi A O, McCreedy T. Microchip based sample treatment device interfaced with ICP-MS for the analysis of transition metals from environmental samples. Arab J Chem, 2011, 4: 195–203
An M I, Zhang X, Yang T, et al. Uptake and speciation of inorganic arsenic with cellulose fibre coated with yttrium hydroxide layer as a novel green sorbent. Chin J Chem, 2012, 30: 2225–2231
Chamjangali M A, Bagherian G, Mokhlesian A, et al. Synthesis and application of chloromethylated polystyrene modified with 1-phenyl-1,2-propanedione-2-oxime thiosemicarbazone (PPDOT) as a new sorbent for the on-line preconcentration and determination of copper in water, soil, and food samples by FAAS. J Hazard Mater, 2011, 192: 1641–1649
Chamjangali M A, Goudarzi N, Mirheidari M, et al. Sequential eluent injection technique as a new approach for the on-line enrichment and speciation of Cr(III) and Cr(VI) species on a single column with FAAS detection. J Hazard Mater, 2011, 192: 813–821
Chen M L, An M I. Selenium adsorption and speciation with Mg-FeCO3 layered double hydroxides loaded cellulose fibre. Talanta, 2012, 95: 31–35
Chen M L, Ma H J, Zhang S Q, et al. Mercury speciation with L-cysteine functionalized cellulose fibre as adsorbent by atomic fluorescence spectrometry. J Anal At Spectrom, 2011, 26: 613–617
Chen M L, Zhao Y N, Zhang D W, et al. The immobilization of hydrophilic ionic liquid for Cr(VI) retention and chromium speciation. J Anal At Spectrom, 2010, 25: 1688–1694
Daneshfar A, Ghaedi M, Vafafard S, et al. Amberlite IR-120 modified with 8-hydroxyquinoline as efficient adsorbent for solid-phase extraction and flame atomic absorption determination of trace amounts of some metal ions. Biol Trace Elem Res, 2012, 145: 240–247
Islam A, Ahmad A, Laskar M A. A newly developed salicylanilide functionalized Amberlite XAD-16 chelating resin for use in preconcentration and determination of trace metal ions from environmental and biological samples. Anal Methods, 2011, 3: 2041–2048
Kumar B N, Ramana D K V, Harinath Y, et al. Separation and preconcentration of Cd(II), Cu(II), Ni(II), and Pb(II) in water and food samples using Amberlite XAD-2 functionalized with 3-(2-nitro-phenyl)-1H-1,2,4-triazole-5(4H)-thione and determination by inductively coupled plasma-atomic emission spectrometry. J Agric Food Chem, 2011, 59: 11352–11358
Norisuye K, Sohrin Y. Determination of bismuth in open ocean waters by inductively coupled plasma sector-field mass spectrometry after chelating resin column preconcentration. Anal Chim Acta, 2012, 727: 71–77
Oliveira E P, Yang L, Sturgeon R E, et al. Determination of trace metals in high-salinity petroleum produced formation water by inductively coupled plasma mass spectrometry following on-line analyte separation/preconcentration. J Anal At Spectrom, 2011, 26: 578–585
Topuz B, Macit M. Solid phase extraction and preconcentration of Cu(II), Pb(II), and Ni(II) in environmental samples on chemically modified Amberlite XAD-4 with a proper Schiff base. Environ Monit Assess, 2011, 173: 709–722
Anthemidis A N, Giakisikli G, Zachariadis G A. The HyperSep SCX micro-cartridge for on-line flow injection inductively coupled plasma atomic emission spectrometric determination of trace elements in biological and environmental samples. Anal Methods, 2011, 3: 2108–2114
Anthemidis A N, Maloumidou T. Flow injection online solid phase extraction system using Oasis-HLB (TM) micro-cartridge for chromium(VI) and copper determination by flame atomic absorption spectrometry. Anal Methods, 2011, 3: 1392–1398
Ciftci H, Yalcin H, Eren E, et al. Enrichment and determination of Ni2+ ions in water samples with a diamino-4-(4-nitro-phenylazo)-1H-pyrazole (PDANP) by using FAAS. Desalination, 2010, 256: 48–53
Wang Q, Chang X, Li D, et al. Adsorption of chromium(III), mercury(II) and lead(II) ions onto 4-aminoantipyrine immobilized bentonite. J Hazard Mater, 2011, 186: 1076–1081
Cui C, He M, Hu B. Membrane solid phase microextraction with alumina hollow fiber on line coupled with ICP-OES for the determination of trace copper, manganese and nickel in environmental water samples. J Hazard Mater, 2011, 187: 379–385
Zhang X X, Tang S S, Chen M L, et al. Iron phosphate as a novel sorbent for selective adsorption of chromium(III) and chromium speciation with detection by ETAAS. J Anal At Spectrom, 2012, 27: 466–472
Tian Y, Chen M L, Chen X W, et al. Arsenic preconcentration via solid phase extraction and speciation by HPLC-gradient hydride generation atomic absorption spectrometry. J Anal At Spectrom, 2011, 26: 133–140
Huang Y F, Li Y, Jiang Y, et al. Magnetic immobilization of amine-functionalized magnetite microspheres in a knotted reactor for on-line solid-phase extraction coupled with ICP-MS for speciation analysis of trace chromium. J Anal At Spectrom, 2010, 25: 1467–1474
Li Y, Huang Y F, Jiang Y, et al. Displacement solid-phase extraction on mercapto-functionalized magnetite microspheres for inductively coupled plasma mass spectrometric determination of trace noble metals. Anal Chim Acta, 2011, 692: 42–49
Araujo C S T, Alves V N, Rezende H C, et al. Development of a flow system for the determination of low concentrations of silver using Moringa oleifera seeds as biosorbent and flame atomic absorption spectrometry. Microchem J, 2010, 96: 82–85
Bakircioglu Y, Bakircioglu D, Akman S. Biosorption of lead by filamentous fungal biomass-loaded TiO2 nanoparticles. J Hazard Mater, 2010, 178: 1015–1020
Cheng X, Shao K, Shen S, et al. Determination of trace silver in polymetallic ore samples by flame atomic absorption spectrometry after solid-phase extraction using a microcolumn comprising eggshell membrane. Geostand Geoanal Res, 2011, 35: 461–469
Li Y, Yang J L, Jiang Y. Trace rare earth element detection in food and agricultural products based on flow injection walnut shell packed microcolumn preconcentration coupled with inductively coupled plasma mass spectrometry. J Agric Food Chem, 2012, 60: 3033–3041
Tian Y, Xie Z M, Chen M L, et al. Cadmium preconcentration with bean-coat as a green adsorbent with detection by electrothermal atomic absorption spectrometry. J Anal At Spectrom, 2011, 26: 1408–1413
Yang T, Chen M L, Hu X W, et al. Thiolated eggshell membranes sorb and speciate inorganic selenium. Analyst, 2011, 136: 83–89
Yang T, Chen M L, Liu L H, et al. Iron(III) modification of bacillus subtilis membranes provides record sorption capacity for arsenic and endows unusual selectivity for As(V). Environ Sci Technol, 2012, 46: 2251–2256
Yang T, Zhang X X, Chen M L, et al. Highly selective preconcentration of ultra-trace cadmium by yeast surface engineering. Analyst, 2012, 137: 4193–4199
Afzali D, Mostafavi A, Etemadi F, et al. Application of modified multiwalled carbon nanotubes as solid sorbent for separation and preconcentration of trace amounts of manganese ions. Arab J Chem, 2012, 5: 187–191
Ozcan S G, Satiroglu N, Soylak M. Column solid phase extraction of iron(III), copper(II), manganese(II) and lead(II) ions food and water samples on multi-walled carbon nanotubes. Food Chem Toxicol, 2010, 48: 2401–2406
Yang B, Gong Q, Zhao L, et al. Preconcentration and determination of lead and cadmium in water samples with a MnO2 coated carbon nanotubes by using ETAAS. Desalination, 2011, 278: 65–69
Yuan C G, Zhang Y, Wang S, et al. Separation and preconcentration of palladium using modified multi-walled carbon nanotubes without chelating agent. Microchim Acta, 2011, 173: 361–367
Zhang X, Zhang L, Yang T, et al. Improvement on the selectivity and sorption capacity of cadmium by iron loaded carbon nanotubes with detection by electrothermal atomic absorption spectrometry. J Anal At Spectrom, 2012, 27: 1680–1687
Zhang X X, Chen M L, Yu Y L, et al. Polyelectrolyte-modified multi-walled carbon nanotubes for the adsorption of chromium(VI). Anal Methods, 2011, 3: 457–462
Chang Q, Song S, Wang Y, et al. Application of graphene as a sorbent for preconcentration and determination of trace amounts of chromium(III) in water samples by flame atomic absorption spectrometry. Anal Methods, 2012, 4: 1110–1116
Yang T, Liu L H, Liu J W, et al. Cyanobacterium metallothionein decorated graphene oxide nanosheets for highly selective adsorption of ultra-trace cadmium. J Mater Chem, 2012, 22: 21909–21916
Bakircioglu D, Ucar G, Kurtulus Y B. Coliform bacteria immobilized on titanium dioxide nanoparticles as a biosorbent for trace lead preconcentration followed by atomic absorption spectrometric determination. Microchim Acta, 2011, 174: 367–374
Ezoddin M, Shemirani F, Abdi K, et al. Application of modified nano-alumina as a solid phase extraction sorbent for the preconcentration of Cd and Pb in water and herbal samples prior to flame atomic absorption spectrometry determination. J Hazard Mater, 2010, 178: 900–905
Manzoori J L, Amjadi M, Darvishnejad M. Separation and preconcentration of trace quantities of copper ion using modified alumina nanoparticles, and its determination by flame atomic absorption spectrometry. Microchim Acta, 2012, 176: 437–443
Khajeh M, Sanchooli E. Silver nanoparticles as a new solid-phase adsorbent and its application to preconcentration and determination of lead from biological samples. Biol Trace Elem Res, 2011, 143: 1856–1864
Godlewska-Zylkiewicz B, Lesniewska B, Wawreniuk I. Assessment of ion imprinted polymers based on Pd(II) chelate complexes for preconcentration and FAAS determination of palladium. Talanta, 2010, 83: 596–604
Godlewska-Zylkiewicz B, Zambrzycka E, Lesniewska B, et al. Separation of ruthenium from environmental samples on polymeric sorbent based on imprinted Ru(III)-allyl acetoacetate complex. Talanta, 2012, 89: 352–359
Lesniewska B, Kosinska M, Godlewska-Zylkiewicz B, et al. Selective solid phase extraction of platinum on an ion imprinted polymers for its electrothermal atomic absorption spectrometric determination in environmental samples. Microchim Acta, 2011, 175: 273–282
Zambrzycka E, Roszko D, Lesniewska B, et al. Studies of ion-imprinted polymers for solid-phase extraction of ruthenium from environmental samples before its determination by electrothermal atomic absorption spectrometry. Spectroc Acta Pt B-Atom Spectr, 2011, 66: 508–516
Jia X, Han Y, Liu X, et al. Dispersive liquid-liquid microextraction combined with flow injection inductively coupled plasma mass spectrometry for simultaneous determination of cadmium, lead and bismuth in water samples. Microchim Acta, 2010, 171: 49–56
Anthemidis A N, Ioannou K I G. Sequential injection dispersive liquid-liquid microextraction based on fatty alcohols and poly(ether-etherketone)-turnings for metal determination by flame atomic absorption spectrometry. Talanta, 2011, 84: 1215–1220
Wu Q, Wu C, Wang C, et al. Sensitive determination of cadmium in water, beverage and cereal samples by a novel liquid-phase microextraction coupled with flame atomic absorption spectrometry. Anal Methods, 2011, 3: 210–216
Berton P, Wuilloud R G. An online ionic liquid-based microextraction system coupled to electrothermal atomic absorption spectrometry for cobalt determination in environmental samples and pharmaceutical formulations. Anal Methods, 2011, 3: 664–672
Ranjbar L, Yamini Y, Saleh A, et al. Ionic liquid based dispersive liquid-liquid microextraction combined with ICP-OES for the determination of trace quantities of cobalt, copper, manganese, nickel and zinc in environmental water samples. Microchim Acta, 2012, 177: 119–127
Filik H, Aksu D. Determination of vanadium in food samples by cloud point extraction and graphite furnace atomic absorption spectroscopy. Food Anal Methods, 2012, 5: 359–365
Sun M, Wu Q. Determination of trace bismuth in human serum by cloud point extraction coupled flow injection inductively coupled plasma optical emission spectrometry. J Hazard Mater, 2011, 192: 935–939
Wen X, Deng Q, Ji S, et al. Design of rapidly synergistic cloud point extraction of ultra-trace lead combined with flame atomic absorption spectrometry determination. Microchem J, 2012, 100: 31–35
Durukan I, Sahin C A, Bektas S. Determination of copper traces in water samples by flow injection-flame atomic absorption spectrometry using a novel solidified floating organic drop microextraction method. Microchem J, 2011, 98: 215–219
Sahin C A, Tokgoz I. A novel solidified floating organic drop microextraction method for preconcentration and determination of copper ions by flow injection flame atomic absorption spectrometry. Anal Chim Acta, 2010, 667: 83–87
Sahin C A, Durukan I. Ligandless-solidified floating organic drop microextraction method for the preconcentration of trace amount of cadmium in water samples. Talanta, 2011, 85: 657–661
Mahpishanian S, Shemirani F. Preconcentration procedure using in situ solvent formation microextraction in the presence of ionic liquid for cadmium determination in saline samples by flame atomic absorption spectrometry. Talanta, 2010, 82: 471–476
Zeng C, Wen X, Tan Z, et al. Hollow fiber supported liquid membrane extraction for ultrasensitive determination of trace lead by portable tungsten coil electrothermal atomic absorption spectrometry. Microchem J, 2010, 96: 238–242
Pohl P, Jamroz P. Recent achievements in chemical hydride generation inductively coupled and microwave induced plasmas with optical emission spectrometry detection. J Anal At Spectrom, 2011, 26: 1317–1337
Piston M, Silva J, Perez-Zambra R, et al. Automated method for the determination of total arsenic and selenium in natural and drinking water by HG-AAS. Environ Geochem Health, 2012, 34: 273–278
Ferreira S L C, Lima D C, Moreira I T A, et al. Critical study using experimental design of the determination of lead by high-resolution continuum source hydride generation atomic absorption spectrometry. J Anal At Spectrom, 2011, 26: 2039–2044
Bueno Guerra M B, Carapelli R, Miranda K, et al. Determination of As and Sb in mineral waters by fast sequential continuous flow hydride generation atomic absorption spectrometry. Anal Methods, 2011, 3: 599–605
Guo S, Feng B, Zhang H. Simultaneous determination of trace arsenic and antimony in fomes officinalis ames with hydride generation atomic fluorescence spectrometry. J Fluoresc, 2011, 21: 1281–1284
Li R, Yan H, Yang X, et al. Simultaneous determination of trace lead, tin and cadmium in biological samples by a chemical vapor generation-four-channel atomic fluorescence spectrometry dual gas-liquid separator system. J Anal At Spectrom, 2011, 26: 1488–1493
Savio M, Pacheco P H, Martinez L D, et al. Optimization of methods to assess levels of As, Bi, Sb and Se in airborne particulate matter by FI-HG-ICP OES. J Anal At Spectrom, 2010, 25: 1343–1347
Matusiewicz H, Slachcinski M. Method development for simultaneous multi-element determination of hydride forming elements (As, Bi, Ge, Sb, Se, Sn) and Hg by microwave induced plasma-optical emission spectrometry using integrated continuous-microflow ultrasonic nebulizer-hydride generator sample introduction system. Microchem J, 2010, 95: 213–221
Zheng C, Sturgeon R E, Hou X. Thin film hydride generation: Determination of ultra-trace copper by flow injection in situ hydride trapping graphite furnace AAS. J Anal At Spectrom, 2010, 25: 1159–1165
Zeng C, Zhou N, Luo J. Synergetic enhancement effect of room temperature ionic liquids and ammonium pyrrolidine dithiocarbamate on the chemical vapor generation of iron, cobalt and nickel in environmental and biological samples by atomic absorption spectrometric determination. J Anal At Spectrom, 2012, 27: 120–125
Matusiewicz H, Krawczyk M. Determination of nickel by chemical vapor generation in situ trapping flame AAS. Cent Eur J Chem, 2011, 9: 648–659
Pacheco P H, Spisso A, Cerutti S, et al. Non-chromatographic screening method for the determination of mercury species. Application to the monitoring of mercury levels in Antarctic samples. Talanta, 2010, 82: 1505–1510
Taurkova P, Svoboda M, Musil S, et al. Loss of di- and trimethylarsine on Nafion membrane dryers following hydride generation. J Anal At Spectrom, 2011, 26: 220–223
Tian Y, Chen M L, Chen X W, et al. Arsenic speciation with gradient hydride generation interfacing liquid chromatography and atomic absorption spectrometry. J Anal At Spectrom, 2010, 25: 48–54
Yin Y G, Liu J F, Jiang G B. Photo-induced chemical-vapor generation for sample introduction in atomic spectrometry. Trends Anal Chem, 2011, 30: 1672–1684
Da Silva C S, Oreste E Q, Nunes A M, et al. Determination of mercury in ethanol biofuel by photochemical vapor generation. J Anal At Spectrom, 2012, 27: 689–694
Liu Q. Direct determination of mercury in white vinegar by matrix assisted photochemical vapor generation atomic fluorescence spectrometry detection. Spectroc Acta P B-Atom Spectr, 2010, 65: 587–590
Zhu Z, He Q, Shuai Q, et al. Solution cathode glow discharge induced vapor generation of iodine for determination by inductively coupled plasma optical emission spectrometry. J Anal At Spectrom, 2010, 25: 1390–1394
Zhang W B, Yang X A, Ma Y Y, et al. Continuous flow electrolytic cold vapor generation atomic fluorescence spectrometric determination of Hg in water samples. Microchem J, 2011, 97: 201–206
Tormen L, Gil R A, Frescura V L A, et al. The use of electrothermal vaporizer coupled to the inductively coupled plasma mass spectrometry for the determination of arsenic, selenium and transition metals in biological samples treated with formic acid. Anal Chim Acta, 2012, 717: 21–27
Arkasuwan C, Siripinyanond A, Shiowatana J. Inductively coupled plasma mass spectrometry with a continuous-flow dialysis simulated gastrointestinal digestion for study of arsenic bioaccessibility in shrimp. Int J Mass spectrom, 2011, 307: 61–65
Deng B Y, Wang Y Z, Zhu P C, et al. Identification and analysis of calcium speciation in red blood cells by ultrasonic-dialysis capillary electrophoresis inductively coupled plasma optical emission spectrometry. J Anal At Spectrom, 2010, 25: 1859–1863
Author information
Authors and Affiliations
Corresponding author
Additional information
This article is published with open access at Springerlink.com
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Yu, Y., Wang, J. Recent advances in flow-based sample pretreatment for the determination of metal species by atomic spectrometry. Chin. Sci. Bull. 58, 1992–2002 (2013). https://doi.org/10.1007/s11434-013-5666-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11434-013-5666-9