Introduction

The European Green Deal, and more specifically the Farm to Fork Strategy, strives to reduce the overall use of agrochemicals by 50% by 2030 (EC, 2020). In this respect, the European Commission will enhance the implementation of Integrated Pest Management (IPM). Besides alternative control strategies, such as crop rotation and mechanical weeding, precision spraying techniques can help to achieve this goal.

A perfect spraying system ultimately aims to deliver and deposit a precise amount of active ingredient uniformly and exclusively upon a target area. Ideally, only the exact (minimum) amount of product required to achieve the desired biological effect would be released and all product discharged from the sprayer would reach the desired target (Giles & Comino, 1989). Achieving this goal is extremely challenging for agricultural spray applications; nevertheless, pesticide losses, under- and over-application, as well as inadequate coverage and deposition, should be avoided as much as possible to safeguard the environment, food safety and human health.

Conventional spray applications generally apply agrochemicals at a constant rate (l ha−1) throughout the field, irrespective of pest/disease presence, planting system, crop density or tree canopy characteristics, which contribute to a lower application efficiency. In vineyards, orchards and other fruit productions high variability within and between trees in foliage density, canopy shape and size, typically results in trees being over- or under-sprayed when using a constant rate application (Chen et al., 2019; Salcedo et al., 2020; Zhu et al., 2008).

The quality of pesticide application can potentially be improved by accurately determining the spray rate based on the canopy structure and enhancing the accuracy of the spray rate (Campos et al., 2020; Miranda-Fuentes et al., 2015). Indeed, variable-rate sprayers, which adjust the application rates using flow controllers based on information from real-time or sensor-guided canopy detection systems (e.g. ultrasonic, infrared, light detection and ranging—LIDAR, and stereo vision sensors) (Balsari et al., 2009; Berk et al., 2016; Comba et al., 2019; Palleja & Landers, 2015; Zhang et al., 2018), have been shown to improve spray application efficiency and reduce off-target losses (Cai et al., 2019; Chen et al., 2019; Gil et al., 2007; Jeon & Zhu, 2012; Llorens et al., 2010).

Variable rates can be achieved through pressure-based systems, injection systems, or pulse width modulation (PWM) systems. Pressure-based systems have been shown to have a slow response time and affect nozzle performance, specifically droplet size and spray distribution (Giles & Comino, 1989). Similarly, direct injection systems that inject the active ingredient upstream of the nozzle, were reported to show application errors caused by lag effects (Anglund & Ayers, 2003). The PWM technology controls the nozzle flow rate by pulsing an electronically-actuated solenoid valve directly upstream of the nozzle. The flow is changed by controlling the relative proportion of time each solenoid valve is open (duty cycle). The system therefore allows real-time flow rate changes while maintaining the operating pressure (Butts et al., 2019). The effects of PWM flow control on droplet sizes and velocities were found to be relatively minor, especially compared to pressure-based systems (Giles, 2020; Giles & Ben-Salem, 1992; Giles & Comino, 1990; Giles et al., 2002; Gopala Pillai et al., 1999).

For this reason, PWM technology that allows control of spray droplet size and flow rate of each nozzle independently has been extensively used in the development of innovative variable rate sprayers in accordance with the precision agriculture principles to spray only where and how much is needed. This technology has lead to promising results in reducing both chemical inputs and spray drift. For example, Salcedo et al. (2020) reported more than 65% spray volume reduction with a laser-guided PWM-controlled variable rate air-blast orchard sprayer compared to a constant rate application with the same sprayer (by disabling the PWM control system) in two-year old apple trees, while still providing sufficient spray deposits and coverage for effective fungicide and insecticide applications (proposed by pesticide manufacturers) without over-application. Furthermore, in this study, it was proven that the use of PWM solenoid valves improved distribution uniformities of both spray deposition and coverage. Previously, Chen et al. (2013) found similar results.

Despite promising results, concerns still exist regarding the spray coverage accuracy and uniformity with the PWM system due to the solenoid on/off latency and the alternating on/off action of adjacent nozzles in some systems. Mangus et al. (2017) identified through lab based simulation that, although an accurate flow rate was emitted per pulse (regardless of duty cycle and number of nozzles activated), spray coverage accuracy decreased as duty cycle decreased, meaning lower duty cycles resulted in a lower percentage of area receiving the target application rate, and thus in more under- or over-application. In the early stages of PWM technology development, Giles and Comino (1990) found that a reduction in duty cycle resulted in spray distribution patterns with significantly more spray deposit directly underneath the nozzles and reductions in the outer regions of the pattern. The distortion was relatively minor for the tested flat-fan nozzles and severe for the solid-cone nozzles. Although several authors have recently studied the effect of PWM on droplet size spectra, activation pressure and flow rate at different duty cycles with different nozzle types (Butts et al., 2018, 2019; Deng et al., 2020; Llorens & Hewitt, 2019; Wei et al., 2020), very few studies on the use of PWM in field conditions are available in the literature, especially for 3D crops, where the interest for the PWM system for variable rate applications increases daily. Therefore, more studies in real field conditions are needed to better understand the efficacy of PWM systems in applying chemicals to valuable, widespread crops, such as vineyards and orchards.

The objective of this study was to test the effect of PWM duty cycle and sprayer forward speed on the spray coverage variability (i) along the sprayer track and canopy height at the edge of the canopy using long water sensitive papers (WSP; plot L), and (ii) along the canopy height and canopy depth using short WSPs (plot S) in a 11 years old vineyard at full growth stage. Contextually, an estimation of the most suitable spray volume to obtain an efficient spray application that minimizes overspray and maximizes the potential efficacy of plant protection products was also carried out.

Materials and methods

Droplet size and velocity characteristics

Preliminary tests were conducted to determine the effect of PWM duty cycle and the presence of a solenoid valve on the spray droplet size and velocity characteristics. Laboratory trials were conducted at the ILVO Spray Technology Lab using the DynaJet® Flex 7140 PWM system at the default setting of 20 Hz (TeeJet, Spraying Systems Co., Wheaton, Illinois USA). Measurements were performed using a Phase Doppler Particle Analyser (PDPA), as described by Nuyttens et al. (2007). The PDPA laser used was an Aerometrics PDPA one dimensional system (TSI, Minneapolis, USA). When a droplet passes through a small sampling volume, formed by two intersecting laser beams, light is scattered by refraction. From the light scattering characteristics, droplet sizes and velocities are obtained. Measurements were carried out with the standard flat fan nozzle XR8002 VS (TeeJet, Spraying Systems Co., Wheaton, Illinois USA) at 4 duty cycle settings (30%, 50%, 70%, 100%) at 0.40 MPa and at a distance of 0.5 m below the nozzle. Tests were carried out without air support using a single nozzle set-up, and were repeated three times.

Sprayer characteristics and configurations tested in field trials

A prototype vineyard sprayer developed in the ambit of the H2020 OPTIMA project (http://optima-h2020.eu/), i.e. Smart Synthesis (Caffini S.p.a., Palù, Verona, Italy), was employed. It is a trailed sprayer with a 1 000 l polyethylene tank and an innovative axial fan with an electrical engine (KEB automation KG, Barntrup, Germany). The fan, 700 mm in diameter and consisting of nine blades, sucks in the air from the front of a tower shaped air conveyor (Fig. 1a). The latter is equipped with multiple adjustable deflectors placed internally at the edge of the air-jet outlet, thus allowing direction of the airflow to match the canopy height. An electric-control varies the orientation of the whole air conveyor with respect to the central axis of the air-jet discharge system backwards and forward, thus determining the incidence angle of both airflow and spray jets on the canopy. The sprayer was equipped with a DynaJet® Flex 7140 PWM system (TeeJet, Spraying Systems Co., Wheaton, Illinois, USA). On each side of the sprayer, a vertical boom was mounted to the air-conveyor, each containing eight PWM solenoid valves coupled with a single nozzle holder, placed at 180 mm spacing along the boom (Fig. 1b). The PWM valves varied the duty cycle of the pulse signals to change the spray outputs (at a frequency of 20 Hz). The PWM system uses a blended pulse in which every other nozzle operates at an alternate frequency. So, below 50% DC, two adjacent nozzles can be off at the same time, resulting in no spray for very short periods of time (less than 25 ms at 20 Hz) and thus possibly zones with no or low amounts of spray deposit resulting in a high variation in spray coverage. In this study, each trial was undertaken at a constant spray application rate by using a fixed duty cycle (30%, 50%, 70%, 100%) which was manually set through a dedicated DynaJet control unit at the start of each trial.

Fig. 1
figure 1

Smart synthesis vineyard sprayer featured by tower shaped air-jet discharge system, axial fan with electrical engine, and PWM DynaJet® system controlling the sprayed liquid rate of 16 nozzles. a Aerial view and b back view. During the field trials the nozzles N7, N8, N15 and N16 were disabled

The sprayer was equipped with standard flat fan nozzles XR8002 VS (TeeJet, Spraying Systems Co., Wheaton, Illinois USA). The trials were carried out at a working pressure of 0.40 MPa, corresponding to a nominal nozzle flow rate of 0.91 l min−1. Based on a preliminary check of the vertical spray profile, considering an intended canopy target height of 2.0 m, only the bottom six nozzles on each side of the sprayer were activated. The upper nozzles (N7, N8, N15, N16) were turned off (Fig. 1b). The internal air deflectors were adequately adjusted to match the canopy height and to minimize spray losses over the target height. All trials were conducted at a fixed fan revolution speed of 1 600 rev min−1, producing an average airflow of 17 050 m3 h−1. The mean air velocity at the air outlet was 20.4 m s−1. The electric axial fan ensured a fixed and constant fan revolution speed, irrespective of the PTO revolution speed, throughout the duration of the trials. The air conveyor was placed orthogonal to the rows (90° relative to the central axis of the air-jet discharge system) in all trials (Fig. 1a).

In total, twelve sprayer configurations, deriving from the combination of four PWM duty cycles (30, 50, 70, 100%) and three forward speeds (4.0, 6.0 and 8.0 km h−1 corresponding to 1.11, 1.67 and 2.22 m s−1, respectively) were tested resulting in spray application rates ranging from 87.8 up to 585.0 l ha−1. Three replicates were conducted for each configuration tested. The main variables examined are summarized in Table 1. The order in which configurations and replications were tested was fully-randomized using Excel software function.

Table 1 Sprayer configurations tested with the smart synthesis vineyard sprayer using 12 active TeeJet XR 8002 VS nozzles at 0.4 MPa

Field test location and vineyard characteristics

In September 2020, field trials were carried out in an espalier-trained vineyard (cv: Barbera) at growth stage BBCH 89 “Berries ripe for harvest” (Lorenz et al., 1994) located at DiSAFA facilities in Grugliasco, Turin, Italy. The vine rows were 62 m long and oriented NW–SE (146° azimuth) (Fig. 2). Planting distances were 2.8 m between rows and 0.8 m within rows with a resulting density of 4 464 vines ha−1. To accurately characterize the vineyard crop, the point quadrat technique (PQT) was used as described in detail by Grella et al. (2019) and Vitali et al. (2013). At six blocks, distributed in the first two rows (three blocks per row), and at four vine canopies per block, PQT measurements were taken in the vegetative strip at heights between 0.4 and 2.2 m. The average vineyard height from the ground was 2.08 m with a vegetative strip of 1.48 m and a canopy width of 0.48 m. The mean vegetative parameters were 2.2 leaf layers, 13.1% gaps, and a leaf area index (LAI) of 1.31, calculated according to Pergher and Petris (2008).

Fig. 2
figure 2

a Schematic of trial layout for the spray coverage measurements in field-standardized conditions (plot L) and in real field conditions (plot S). b Aerial view of the vineyard field trial area

Experimental plot layout and sampling system

The trials were carried out in the two outermost rows of the vineyard. Along each of these rows, two test plots (L and S) were established (Fig. 2). Each plot was characterized by a total area of 174 m2 (31.0 m × 5.6 m).

The variability of spray coverage at the edge of the canopy along (i) the sprayer track and (ii) the canopy height was measured in plot L under field-standardized conditions by spraying only from one side of each row (Fig. 2). For this purpose, long strips of WSP (500 mm × 26 mm, Syngenta Crop Protection AG, Basel, Switzerland) were used. Field-standardized conditions were obtained by avoiding interaction of the spray with the leaves, while still allowing interaction between the spray plume and the air-jet from the sprayer, as the latter influences the spray droplet trajectories. This was done to gain insight into the effect of the PWM system and alternating nozzles on the theoretical spray coverage with minimal interference of other factors. To evaluate the variability of spray coverage along the sprayer track, two ad hoc wooden frames held the long WSPs horizontally at three different heights, namely at 0.8 m (grapes band), 1.4 m (middle of the vegetation strip) and 2.0 m (top of the vegetation strip) from the ground (respectively H1, H2, and H3; Fig. 3a and b). To evaluate the variability of spray coverage along the canopy height, two additional wooden frames held long WSPs vertically from 0.5 to 2.0 m from the ground at three advancing distances each 1.0 m apart (respectively D1, D2, and D3; Fig. 3c and d). In each sampled position, namely at the three canopy heights and at the three distances along the row, three long WSPs were aligned next to each other in order to simulate a unique WSP collector of 1 500 mm length with a total exposed surface of 390 cm2 (Fig. 3a and c). In both cases, one frame was placed on the right side of row 1 and the other on the left side of row 2 to evaluate the target coverage of the spray-jet generated by respectively the left and right side of the sprayer (Fig. 3b and d). The frames were positioned at the edges of the canopy, thus avoiding interference with canopy leaves, and were maintained in the same position for all trials and replicates. The wooden frames were distributed in the test plot ensuring 7 m distance between the frames used to measure the variability of spray coverage along the sprayer track and those used to assess the variability along the canopy height. Per replicate, a single sprayer pass in the alley between row 1 and 2 was carried out by applying pure water (Fig. 2a).

Fig. 3
figure 3

Three-dimensional schematic and real-field sampling positions of the WSP lines for the evaluation of spray coverage homogeneity a, b along the sprayer track at three heights (H1, H2, H3) and c, d along the canopy height at three advancing distances (D1, D2, D3). Each WSP line is composed of three long WSPs aligned and clipped to the wooden structure. The grey, dashed lines represent the tree row volume (Color figure online)

The spray coverage inside the canopy was measured in plot S under real field conditions by spraying both sides of the rows (Fig. 2). Real field conditions were obtained by allowing both interaction of the spray and the air-jet with the leaves. For this purpose, the sampling strategy described by Grella et al. (2020) was adopted. The spray coverage was assessed at nine sampling positions per vine arranged at three heights (1: bottom, 2: middle, 3: top) and three depths (A: right edge, B: middle, C: left edge). At each sampling location, two paired short WSPs (76 mm × 26 mm, Syngenta Crop Protection AG, Basel, Switzerland), attached to the upper and lower leaf surface, were directly stapled to the leaf. In the process of selecting sample locations on real vines, the guidelines were to staple the WSP as close to the designated location as possible, given that there were leaves available for stapling. Where and when possible the WSPs were stapled to the same leaves. If not possible, the nearest leaves were selected. Within row 1 and 2, one canopy vine per row was sampled and the two sampled canopies were situated 11 m apart (Fig. 2a). The proposed sampling strategy is broadly used to assess leaf coverage under real conditions during spray application field trials (Hołownicki et al., 2002; Rincón et al., 2020; Salcedo et al., 2020; Salyani et al., 2013).

The two plots were sprayed consecutively using pure water, meaning that the sprayer started the spray application in plot L in the alley between rows 1 and 2, and continued the application in plot S without stopping, then the left side of row 1 and the right side of row 2 were sprayed in plot S only (Fig. 2a). At the end of each spray application, the WSPs were collected, labelled using a unique code, and stored under controlled, dry conditions.

The environmental conditions were monitored over the full duration of the trials using a weather station placed 15 m away from the sprayed area in a crop free area, at the intersection of the test plots (Fig. 2a). The weather station was equipped with a sonic anemometer 232 (Campbell Scientific, Logan, UT, USA) at 4.0 m height to measure wind speed and direction relative to the spray track, and two thermo-hygrometer HC2S3 probes (Campbell Scientific) placed at 2.0 and 4.0 m heights to measure air temperature and relative humidity (RH). All measurements were taken at a frequency of 0.1 Hz and all data were recorded automatically by a data logger CR800 (Campbell Scientific). The mean air temperature was 22.8 °C, mean RH was 54.5%, average wind speed recorded in each trial was always below 1.48 m s−1. The weather conditions accomplish the optimal conditions for spray application defined by the best management practices (BMPs) (TOPPS-Prowadis Project, 2014). In all cases, the trials were conducted in “light air” conditions (Barua, 2005), making the data derived from the different trials broadly comparable. The weather data recorded during the trials are shown for each configuration and replicate in Table 6 in appendix.

Sample processing and WSP analysis

Prior to the sample analysis, the long WSPs were cut into sections of 50 mm (ten sections per long WSP). Each collector line composed of three aligned long WSPs (1500 mm × 26 mm) thus generated 30 sections (Fig. 12). From each collector line, the 30 WSP sections (50 mm × 26 mm, ntot = 12,960) were then fixed on a single rigid support next to each other. The short WSPs (76 mm × 26 mm, ntot = 1,296) were also fixed to a single rigid support. The WSPs were then scanned and images were produced at a resolution of 600 dpi using a HP Color Laser Jet Pro MPF M479dw printer with integrated scanner (HP, Palo Alto, California, U.S.A.). A specially programmed image processing macro (Miranda-Fuentes et al., 2016; Zhu et al., 2011) in ImageJ (National Institutes of Health, Bethesda, MD, USA) (Rueden et al., 2017) was used to determine the spray coverage parameters. Spray coverage (%) was calculated as the percentage area covered with the spray deposits on the WSP and deposits density (no stains cm−2) was determined as the number of spray deposit stains per unit of WSP target area (Cerruto et al., 2019).

Data analysis

All statistical analyses were performed using IBM SPSS Statistics (Version 26) predictive analytics software for Windows. The data were tested for normality using the Shapiro–Wilk test and by visual assessment of the Q–Q plots of Z-scores for both the spray coverage and deposits density. Residuals analyses were also performed. An Arcsin[…] transformation was used to achieve residual normality and homoscedasticity of data, expressed as percentage. The data derived from the two test plots were analysed separately.

Regarding the long WSPs (plot L), the coefficient of variation (CV, %) of the spray coverage was calculated per sampling position and used as indicator for variability of the spray coverage along the sprayer track (CVsprayer track for the horizontal lines) and along the canopy heights (CVcanopy height for the vertical lines). A three-way analysis of variance (ANOVA) was used to establish the effect of the independent variables duty cycle (DC), forward speed (FS) and the position of the WSP sampling line (LP) on the dependent variables CVsprayer track and CVcanopy height.

A four-way ANOVA was used to test the effect of the independent variables DC, FS, canopy depth (Dlev) and canopy height (Hlev) on the dependent variables, spray coverage (SC, %) and deposit density (Nst, no of stains cm−2) obtained from the S plot. The dependent variables were considered separately for the upper (SCup and Nst-up) and lower (SClo and Nst-lo) leaf sides and as an average of both sides (SC and Nst). Prior to the analyses of variance, the random effects of sampled row and replicates were investigated and the null hypotheses were accepted. In all cases, the means were compared using a Duncan post-hoc test for multiple comparison (p < 0.05).

If significant differences were observed among FS and DC, the uniformity of spray coverage among samples on each vine canopy was evaluated for each configuration by means of the uniformity index (IU) using Eq. 1. The index was originally proposed by Chen et al. (2013) and recently used by Salcedo et al. (2020) considering only the upper leaf side, but was adjusted here to take into account the uniformity of spray coverage measured on both leaf sides. To further investigate the effect of FS and DC on the uniformity of spray coverage under real-field conditions, a two-way ANOVA was performed using IU as dependent variable.

$$I_{U} = \frac{{\mathop \sum \nolimits_{i}^{{C_{n\_up}^{2} }} u_{i} + \mathop \sum \nolimits_{i}^{{C_{n\_low}^{2} }} u_{i} }}{{c_{n\_up}^{2} + c_{n\_low}^{2} }}$$
(1)

where:

IU: uniformity index for spray coverage (0 to 1, with higher values indicating greater uniformity); i: order of comparison (1, 2,…, \({C}_{n\_up}^{2}\) or 1, 2,…, \({C}_{n\_low}^{2}\)); n_up or n_low: number of groups in a direction to be compared (n is 3 for the y-direction, i.e. canopy depth, or z-direction, i.e. canopy height) for the upper (n_up) or lower (n_low) leaf sides; \({C}_{n\_up}^{2}\) or \({C}_{n\_low}^{2}\): total number of possible combinations of two comparisons (e.g. \({C}_{3\_up}^{2}\) = 3 for either the y or z direction and \({C}_{3\_low}^{2}\) = 3 for either the y or z direction); ui: outcome of Duncan post-hoc test for comparison of the two groups in one combination (ui = 0 when they are significantly different, and ui = 1 when they are not significantly different).

In addition, the spray deposition qualities generated by the tested configurations were evaluated to define the most suitable spray application volume according to the treatment specification (e.g. insecticide or fungicide) in order to maximize the efficacy of spray application, while at the same time minimizing overspray. The thresholds provided by Syngenta Crop Protection AG and widely used by other authors were adopted (Chen et al., 2013; Miranda-Fuentes et al., 2015; Salcedo et al., 2020). Overspray was defined as any situation with spray coverage greater than 30%, while effective insecticide and fungicide spray applications were considered at deposit densities higher than 30 and 70 stains cm−2, respectively, which are rather conservative thresholds. To verify the suitability of the thresholds used, the linear relationship and the correlation between SC and Nst, measured on both upper and lower leaf side, were evaluated for each configuration. Finally, dual y-axis charts with percentage of WSP not oversprayed and percentage of WSP with deposit density higher than the defined thresholds (y-axes) were used to define the optimal spray application volume (x-axis) for both insecticide and fungicides spray application.

Results and discussion

Droplet size and velocity characteristics

An overview of the most important droplet size and velocity characteristics of the XR 8002 nozzle spraying at 0.4 MPa pressure without solenoid valve and with solenoid valve working at different duty cycles (30%, 50%, 70%, 100%), and measured at 0.5 m under the spray boom is given in Table 2, with:

  • Dv0.1, Dv0.25, Dv0.5, Dv0.75, Dv0.9 being the volume diameter (µm) below which smaller droplets constitute respectively 10, 25, 50, 75, and 90% of the total volume;

  • vv0.1, vv0.25, vv0.5, vv0.75, vv0.9 being the droplet velocity (m s−1) below which slower droplets constitute respectively 10, 25, 50, 75, and 90% of the total spray volume;

  • V100 being the percentage of total spray volume with droplets ≤ 100 µm (%), also referred to as the driftables fines.

Table 2 Mean droplet size, velocity characteristics and standard deviation of the mean (σ) for XR 8002 spraying at 0.4 MPa without solenoid valve and with solenoid valve at different duty cycles

The PDPA measurements indicate that the addition of a solenoid valve to the spray system and operated at 100% duty cycle slightly reduced the droplet size of the tested standard flat fan nozzle (Dv0.5 no solenoid valve vs. solenoid valve at 100% DC = 250 vs. 228 µm). Duty cycle had no clear effect on droplet size, although a very small physical effect towards smaller droplets with reduced duty cycle was observed for the finest droplets (Dv0.1, Dv0.25, Dv0.5), i.e. maximum 10 µm reduction from 100 to 30% duty cycle. The percentage of driftables fines (V100) increased due to the presence of a solenoid valve and as duty cycle decreased. Butts et al. (2019) reported variable effects of the addition of the solenoid valve on the droplet size distribution from venturi nozzles but, similar to this study, they found a decrease in droplet size for most non-venturi nozzles. Those authors also measured the nozzle tip pressure and found a decrease in pressure across the solenoid valve with non-venturri nozzles, which does not explain the decrease in droplet size from those nozzles. A lower Dv0.5 in the presence of a solenoid valve could indicate a finer droplet size spectrum confirming the higher V100 value. Further research should be conducted to identify the underlying cause. Unlike this study, Butts et al. (2019) found that droplet size generally increased and percentage of driftable fines reduced as duty cycle decreased, for both venturi and non-venturi nozzles. Similarly, Giles and Comino (1990) reported a significant effect of duty cycle on Dv0.1 and Dv0.5 for a flat fan nozzle, with an increase in droplet size as duty cycle decreased. According to those authors, the effects on droplet size spectra were most often observed as the generation of a few large droplets rather than a shift of the entire spectrum to larger diameters. In accordance with Butts et al. (2019), it is therefore suggested that the increase in spray drift potential with the PWM system due to the reduced droplet size is minimal, especially when compared to conventional sprayers implementing similar flow rate changes. Wei et al. (2020) also reported increased droplet sizes with decreased duty cycles for XR 8001 to XR 8006 flat fan nozzles at 0.276 MPa using two different PWM systems from different manufacturers. These findings were explained by an increase in the travel distance of the spray sheet (i.e. the distance between the nozzle orifice and the breakup of the sheet) with decreased duty cycle, making them more prone to larger droplets. Furthermore, when duty cycle decreased, the authors noticed an increase in pressure upstream of the valve, whereas the activation pressure (i.e. the pressure between the valve and the nozzle orifice when the valve is open) decreased. The operating pressure was not adjusted when the duty cycle changed, contrary to this study. The droplet size distribution of the XR 8002 nozzle controlled by the TeeJet PWM system showed little variation with duty cycle in both the study of Wei et al. (2020) and in this study. Between 100 and 30% duty cycle, Wei et al. (2020) found coefficients of variation of 1.7%, 2.1% and 4.0%, and maximum differences of 4 µm, 7 µm and 27 µm for Dv0.1, Dv0.5, and Dv0.9, respectively. In this study, differences between 100 and 30% were up to 10 µm and coefficients of variation ranged from 3.8% for Dv0.1 to 0.8% for Dv0.9. At smaller droplet sizes, a larger variation was thus found in this study than in the study by Wei et al. (2020), whereas at larger droplet sizes, lower variation was found. These findings are hard to explain as different measuring methodologies were used. More specifically, Wei et al. (2020) measured 10000 effective droplets over a 35 cm range of the long-axis spray pattern while not adjusting the operating pressure with changing duty cycle whereas, in this study, the entire spray pattern was scanned, a minimum of 10000 droplets measured and operating pressure was kept constant at 0.4 MPa over the different duty cycles.

The addition of a solenoid valve also considerably reduced the droplet velocity of the tested standard flat fan nozzle (vv0.5 no solenoid valve vs. solenoid valve at 100% DC = 5.6 vs. 4.4 m s−1). Droplet velocity was decreased by decreasing the duty cyle in this study. Giles and Ben-Salem (1992) also found decreased droplet velocities with decreased duty cycle with a flat fan nozzle (tested at 60%, 30% and 10% duty cycle), although the effects were relatively small and not always significant. Likewise, Butts et al. (2018) reported decreased droplet velocities with decreased duty cycle for venturi and non-venturi nozzles, but found that the average droplet velocity either remained the same or slightly increased when a solenoid valve was operated at 100% duty cycle when compared to the standard configuration without a solenoid valve. The reduction in droplet velocity can be explained by the decrease in nozzle tip or activation pressure with the addition of a solenoid valve or with decreased duty cycle, as observed by Butts et al. (2019) and Wei et al. (2020) and as reported earlier. As suggested by Butts et al. (2018), the droplet velocity reduction using the PWM system could increase spray drift potential and reduce canopy penetration. However, Giles et al. (2002) demonstrated that the reduction in droplet velocity with flow rate was considerably lower with pulsed flow control than with conventional pressure control. This implies that the potential increase in drift potential with a PWM sprayer at lower duty cycles is lower than that obtained with a conventional sprayer with pressure-based control for a similar flow rate decrease.

Spray coverage under field-standardized conditions (plot L)

The mean spray coverage measurements (SC, %) at the three canopy heights on the edges of the vine canopies are shown in Fig. 4. Irrespective of FS and DC, mean SC was always lowest at 2.0 m canopy height (H3) with a maximum of 27.2% at the highest spray volume applied (585.0 l ha−1, FS4_DC100) and a minimum of 6.6% at the lowest spray volume (87.8 l ha−1, FS8_DC30) (Table 7 in appendix). On the other hand, very high mean SC values were found at the other canopy heights, ranging from 28.4 to 87.2% at 0.8 m and from 38.6 to 86.8% at 1.4 m height for the extremes in spray volume, with a proportional increase in relation to the applied volume. The discrepancy between the lower canopy heights (H1 and H2) and the highest one (H3) could be explained by the sprayer configuration. On each sprayer side, only the six lower nozzles were activated (Fig. 1). According to preliminary tests, this should have been the best configuration to maximize the canopy deposition and minimize the spray losses to the air. Compared to the lower heights, less spray was thus directed to the top of the vegetation, resulting in lower spray coverage at 2.0 m canopy height. For all canopy heights, mean SC increased with increasing DC. Furthermore, the differences in mean SC between 0.8 and 1.4 m became less pronounced as DC increases, suggesting the influence of DC on the vertical spray profile. Furthermore, Fig. 4 shows more pronounced variations in SC profile at lower DC, regardless of FS, suggesting an effect of DC on SC variability along the travel direction. Indeed, this effect was confirmed by the three-way ANOVA which showed a significant effect of DC, FS and LP on CVsprayer track (Table 3). Despite different spray volumes due to differences in FS, DC thus influences the uniformity of spray coverage along the sprayer travel direction, with higher variability at lower DC. The not significant interaction FSxDC indicates that the influence of DC on SC variability is independent of FS. Concurrently, the spray coverage variation increased with increasing FS irrespective of DC level. This trend can be explained by a decrease in application volume, as well as a decrease in air volume delivered per linear-meter of row when the FS was increased. Świechowski et al. (2004) demonstrated that the penetration of air in the canopy was fully affected by the sprayer travel speed especially for a cross-flow sprayer characterized by high volume/low speed air jet, affecting the SC uniformity in vineyard (Cerruto, 2007). Based on a visual assessment of Fig. 4, the variation in spray coverage was lowest at 2.0 m canopy height. The significant interactions FSxLP and DCxLP furthermore suggest effects of both FS and DC on the vertical spray profile, not only along the sprayer travel direction.

Fig. 4
figure 4

Spray coverage (%) on the WSP sections obtained from the WSP lines placed horizontally at different heights above the ground (H1 = 0.8 m, light-blue circles; H2 = 1.4 m, red squares; H3 = 2.0 m, green triangles-down) for the different forward speed and duty cycle combinations. The symbols show the mean ± standard error of the mean. The applied volumes (l ha−1) are also shown for the different combinations of duty cycle and forward speed (Color figure online)

Table 3 Results of the three-way ANOVA (p < 0.05) for the spray coverage coefficient of variation (CV, %), analysed separately for the horizontal (CVsprayer track, %) and vertical (CVcanopy height, %) WSP lines

To illustrate the effects on the vertical spray profiles, the mean spray coverage values (SC %) at three distances along the canopy height are shown in Fig. 5. The visual analysis shows that, independent from FS and DC, the SC profiles at the three distances align almost perfectly. Indeed, very little SC variation was noticed between the different vertical WSP lines. Over the 3 distances, SC ranged from 74.3 to 76.7% at the maximum spray volume and from 21.8 to 24.0% at the minimum spray volume (Table 7 in appendix). As already mentioned, the use of only the lower six nozzles per sprayer side explains the lower SC in the top part of the WSP lines. The highest SC was measured at the central part of the WSP lines. However, irrespective of FS, increasing DC increased SC at the bottom part of the vegetation, resulting in values equal or similar to those observed at the central part. SC was also found to increase with DC at the central and top of the vegetation, but to a lesser extent than at the bottom. The three-way ANOVA shows a significant effect of DC, as well as FS, LP, and the interaction FSxDC on CVcanopy height (Table 3). The significant interaction FSxDC underlines the combined effect of FS and DC on the vertical spray profile irrespective of the sprayer travel position. Interestingly, the significant effect of LP confirms the results achieved using horizontal WSP lines: the DC and FS affect the SC variability along the travel direction.

Fig. 5
figure 5

Spray coverage (%) on the WSP sections obtained from the WSP lines placed vertically at different advancing positions (D1 = 0 m, light-blue circles; D2 = 1 m, red squares; D3 = 2 m, green triangles-down) for the different forward speed and duty cycle combinations. The symbols show the mean ± standard error of the mean. The applied volumes (l ha−1) are also shown for the different combinations of duty cycle and forward speed (Color figure online)

The effect of DC on both CVsprayer track and CVcanopy height was investigated in more detail for each FS separately using a Duncan post-hoc test for multiple comparisons. The results are shown in Fig. 6a and b for CVsprayer track and CVcanopy height, respectively. A clear trend within FS was observed, with a decrease in CV, and thus a decrease in SC variability, as DC increases from 30 to 100%, although not always significant. Regardless of FS, the CVsprayer track measured for the extremes 30 and 100% DC were in all cases significantly different while intermediate values measured for 50 and 70% DC were not significantly different. Concurrently, two groups could be distinguished for CVcanopy height with 30 and 50% DC being significantly different from 70 and 100% DC, except at the lowest forward speed of 4 km h−1 where CVcanopy height at 70 and 100% DC also significantly differed. In general, CVcanopy height was higher than CVsprayer track due to the lower coverage in the top part of the canopy. Finally, the comparison of CVsprayer track obtained from configurations FS4_DC50 and FS8_DC100, where the same volume was applied (292.5 l ha−1) by different combinations of DC and FS, were significantly different, confirming the effect of DC and FS on the variability of spray coverage.

Fig. 6
figure 6

Comparison of a CVsprayer track and b CVcanopy height for the different forward speed and duty cycle combinations. The bars show the mean ± standard error of the mean. Different letters and symbols on the bars denote significant differences (Duncan post hoc test, p < 0.05)

The use of the field-standardized methodology, with WSP lines fixed on a rigid wooden frame and completely exposed to the spray jets without interference of vine leaves, allowed a broad comparison of the effect of DC on the SC variability, both along the sprayer travel direction and within the spray profile. However, this practice deviates from reality as, during real spray applications, the leaves move due to the sprayer fan airflow and they interfere with each other and with the spray cloud depending on their position within the vine canopy and on the canopy density. Although no similar experimental field research on 3D crops is available in the literature, the effect of DC on CVsprayer track (Fig. 6a) was comparable with the results found by Pierce and Ayers (2001). Those authors used boom sprayers and a similar method of measurement (CV % of SC measured along long WSP strips). Pierce and Ayers (2001), using PWM valves pulsing at 15 Hz frequency, found CV % higher (in the range from 65 to 10% for 25 to 100% DC) compared to those found in this study (in the range of 25 to 15% for 30 to 100% DC at 8 km h−1). Recently, Mangus et al. (2017) found similar results using a dynamic, theoretical, on-ground spray coverage simulation for a boom sprayer equipped with a PWM system pulsing at 10 Hz. They reported that the coverage might result in scarce homogeneity due to areas with under- or over-spray. A similar trend with an increase in SC homogeneity due to increasing DC was also found by Jiang et al. (2016) with a single nozzle under dynamic laboratory conditions. The effect of FS on the SC homogeneity, evaluated along the sprayer travel direction, confirmed the results found by Deng et al. (2013) in laboratory experiments. Those authors suggest that, as higher travel speeds can enhance the spray heterogeneity along the travel direction (especially when low DC are used), the appropriate traveling speed during pesticide application with PWM system should be carefully chosen so that a more uniform spray distribution is achieved. While in the literature similar results were found as those presented here, it must be emphasized that they refer to experiments carried out with boom sprayers under controlled laboratory conditions and lower frequencies. Nevertheless, a few published data are available about the effect of PWM system (with special focus on DC) on the spray pattern along the boom. Although Pierce and Ayers (2001) suggest that pulsing nozzles had no effect on the spray pattern along the boom, Deng et al. (2020), working with flat fan nozzles (110° spray angle), demonstrated the effect of DC. According to those authors, DC affects (i) the distribution of the spray pattern as it narrows with decreasing flowrates and (ii) the spray angle as it reduces with decreasing flowrate. When the flowrate decreased from 100 to 40% (corresponding to the DC reduction), the average spray angle decreased by 49.8°. The increase in CVcanopy height with the decrease of DC from 100 to 30% (Fig. 6b) found in this study was probably attributable to the combined effect of both these phenomena described by Deng et al. (2020). However, it should be noted that the spray angle can decrease or increase with duty cycle depending on the model and size of the nozzle, the flow rate, and the nozzle tip pressure. It is necessary to take into account that both the forces exerted by the liquid (flow rate, pressure) and the tangential forces produced by the valve are acting on the spray angle.

Spray coverage and deposit density under real field conditions (plot S)

The spray coverage results obtained under real field conditions (plot S) on the upper (SCup) and lower leaf side (SClo) are shown in Fig. 7 through a colour map for the different FS and DC combinations. Heterogeneous SCup and SClo were visually detected. As expected, within each FS, higher SC was obtained at 100% DC, when higher spray volumes were applied, whereas lower values were measured at 30% DC. In addition, SClo was always lower than SCup with an average upper/lower ratio equal to 6.5, 8.1 and 6.7 for 4, 6 and 8 km h−1, respectively; the values were comparable to those found by Hołownicki et al. (2002) in apple tree canopy working at 4 and 6 km h−1. Detailed results averaged over the upper and lower leaf sides (SC) are shown in Table 8 in appendix. The four-way ANOVA (Table 4) shows that FS, DC and sample positions within the canopy, i.e. canopy depth (Dlev) and canopy height (Hlev), significantly affected spray coverage, but some differences occured depending on leaf side. The effect of FS and DC, as well as Dlev and Hlev on the spray coverage can be attributable to the different applied spray volumes. No significant interaction effects were found for SC. The separate analysis of spray coverage according to leaf side showed a significant interaction effect of DlevxHlev, underlining that the effect of canopy depth on spray coverage changes depending on the canopy height level. This confirms the heterogeneity of spray coverage within the vine canopies.

Fig. 7
figure 7

Mean spray coverage (%) on the WSP placed on the upper (SCup) and lower (SClo) leaf sides at different depths (A = right edge; B = middle; C = left edge) and heights (1 = bottom; 2 = middle; 3 = top) in the canopy for the different forward speeds and duty cycle combinations

Table 4 Results of the four-way ANOVA (p < 0.05) for the spray coverage (%) and deposit density (No of stains cm−2), analysed separately for the averaged values, upper and lower leaf sides

The two-way ANOVA showed no significant effect of FS [F(2,12) = 0.056, p = 0.946], DC [F(3,12) = 0.296, p = 0.827) or FSxDC [F(6,12) = 2.574, p = 0.077] on the uniformity index (IU) under real field conditions. Surprisingly, very similar IU values (around 0.8) were reported for both FS and DC (Fig. 8). The IU values obtained were in the same range as those found by other authors in a young apple orchard (Chen et al., 2013; Salcedo et al., 2020), even though they only took into account the upper leaf side. The results found under real field conditions deviated from those obtained under field-standardized conditions in which the effect of FS and DC on the uniformity of spray coverage was well defined (Fig. 8 vs. Fig.6). This effect is not so surprising considering that, under real field conditions, the short WSP were directly stapled to the leaves to simulate the real leaf behaviour influenced by the airstream and spray cloud generated by the sprayer, whereas, under field-standardized conditions, the long WSP were fixed to wooden supports and were completely exposed. Even if the positive effect of DC on spray coverage (due to the increase in spray volume) is well defined, the effect of DC on the uniformity of spray coverage (IU) was nullified under real field conditions. The turbulent airflow generated by the airblast sprayer, used to guide the spray jet into the canopy, eliminated the on–off effect of the PWM solenoids on the spray coverage uniformity inside the canopy, irrespective of DC used. According to Duga et al. (2015) the outlet airflow pattern from sprayers is strongly related to the spray deposition along the canopy height, thus underlining the importance of appropriate and dedicated adjustment of the airflow velocity and direction to the canopy architecture in order to maximize and to obtain uniform deposition throughout the canopy and concurrently reduce spray losses. Fox et al. (2003), investigating the variability of spray coverage, demonstrated through experimental field trials on nursery trees that, for a given spray volume, a factor four to five difference in spray coverage can be found between replicates with WSP collectors placed in the same location (stapled to the same leaf). This variation can be attributed to the interaction between leaves and sprayer airflow, as found by Li et al. (2021). Those authors studied the leaf movement under different airflow velocities and the influence of the leaf aerodynamic response on droplet coverage ratio.

Fig. 8
figure 8

Uniformity index (IU) averaged over a forward speed and b duty cycle. The bars show the mean ± standard error of the mean

Figure 9 displays a colour map of deposit density on the upper (Nst-up) and lower leaf side (Nst-lo) measured at three heights and three depths in the vine canopies for the different FS and DC combinations. In general, within FS, the deposit density increased with DC, both at the upper and lower leaf side. Furthermore, deposit density was always higher at the upper leaf side, except for FS4_DC100 and FS6_DC100 due to massive overlap of stains on the upper leaf side, as also described by Fox et al. (2003) and Grella et al. (2020). Table 4 shows the results of the four-way ANOVA. Even if the main effect of FS and DC on Nst-up was not significant, the significant interaction FSxDC indicates that the effect of FS is dependent on the DC as the overlap of stains becomes more considerable as the applied spray volume increases, resulting in a flattening of deposit density, even if SCup was considerably higher at higher spray volumes (Fig. 7). In contrast, the main effects of FS and DC on Nst-lo were significant as the lower leaf side is generally less exposed to the spray jet, thus being less subjected to stain overlaps. Similarly, FS and DC had a significant effect on the deposit density averaged over both leaf sides (Nst). In addition, Dlev and Hlev significantly affected Nst-up, Nst-lo and Nst. Interestingly, the significant interaction FSxDCxDlev on Nst-up indicates the effect of both FS and DC on the canopy spray penetration: generally lower deposit density was noticed for the middle depth of the canopy irrespective of height position, even if some exceptions can be observed (Fig. 9). Detailed results averaged over the upper and lower leaf sides (Nst) are shown in Table 9 in appendix.

Fig. 9
figure 9

Mean deposit density (no stains cm−2) on the WSP placed on the upper (Nst-up) and lower (Nst-lo) leaf sides at different depths (A = right edge; B = middle; C = left edge) and heights (1 = bottom; 2 = middle; 3 = top) in the canopy for the different forward speed and duty cycle combinations

Spray deposition qualities for the definition of optimal spray application volume

Figure 10 shows the relationships between SC and Nst measured under real field conditions for the different FS and DC combinations. In line with Chen et al. (2013), WSP with SC higher than 30% (dash-dotted black line, Fig. 10) were classified as over-sprayed, thus taking into account that high coverage doesn’t necessarily imply an effective spray application (Garcerá et al., 2011). Thresholds of 30 and 70 stains cm−2 were used to evaluate Nst for effective insecticide and fungicide application, respectively (Salcedo et al., 2020; Zhu et al., 2011). As demonstrated by field trials conducted within best management practices training programs in agriculture (TOPPS-Prowadis Project, 2014), an increase in the application rate might increase the spray coverage but not the biological efficacy of the PPP. The scatter plots in Fig. 10 confirm that the increase of applied spray volume results in an increment of SC with a marked overspray situation. It is therefore often possible to reduce spray volumes without harming the treatment effectiveness. Indeed, in accordance to the results found by other authors (Grella et al., 2020), the best linear relationships between SC and Nst were generally obtained with WSP characterized by SC below 20%. These relationships are presented in Table 5. However, even if only those WSP collectors were considered, the correlation between SC and Nst demonstrates that the Pearson’s coefficient (ρ) and determination coefficient (r2) decrease with applied spray volume. It can therefore be concluded that besides WSP with SC above 20% (Fox et al., 2003; Salcedo et al., 2020), also those with SC below 20% but sprayed with excessive spray volume are characterized by stain overlap. Although the 20% SC threshold was defined as the most suitable for Nst evaluation of WSP collectors in order to minimize the effect of overlapping stains, the 30% threshold (as indicated by the WSP manufacturer and other authors) was nevertheless considered acceptable for Nst measurements.

Fig. 10
figure 10

Plots of deposit density (no of stains cm−2) and spray coverage (%) for the different forward speed and duty cycle combinations. Different colours represent the different applied spray volume (l ha−1). Horizontal dashed red and green lines represent the deposit density thresholds for effective insecticide (30 stains cm−2) and fungicide applications (70 stains cm−2), respectively. The vertical dash-dotted black line represents the spray coverage threshold for the overspray situation (30%). The thresholds were recommended by Syngenta Crop Protection AG (Color figure online)

Table 5 Linear relationships between the deposit density (Nst, no stains cm−2) and surface coverage (SC, %) for the WSP characterized by SC below 20%

Based on these criteria, the percentage of not over-sprayed WSP collectors and the percentage of WSP collectors characterized by Nst higher than 30 and 70 stains cm−2 were selected and plotted against the applied spray volume to obtain the best spray application volumes to minimize over-spray and maximize the density of spray deposition on the vine leaves as indicated by the intersection of the curves. The results are shown in Fig. 11. Based on the vineyard field trials simulating spray applications under real field conditions, the most adequate spray volumes lie between 200 and 250 l ha−1 for insecticide treatments and between 300 and 370 l ha−1 for fungicide treatments. This is in contrast with the current practices adopted by vine farmers as outlined in the OPTIMA survey carried out in 2018, where average spray volumes when applying insecticides were slightly higher than those applying fungicides − 370 vs. 317- (Marucco et al., 2019). To obtain an effective spray application able to minimize overspray and to maximize the deposit density needed according to the treatment specifications, the flat fan nozzle XR 8002 operated at different DC and FS gives the farmer a wide range of options to obtain the most adequate volume, especially when insecticides are applied and lower deposit density is required. When the spray application is intended for fungicides, higher FS are not recommended. Indeed, at 8 km h−1, the curves do not intersect, meaning that a higher spray volume was needed to obtain an effective treatment. However, when the spray application was operated at 8 km h−1 and 100% DC (FS8_DC100, 292.5 l ha−1) the curves were very close to each other (Fig. 11b). Therefore, if the farmer decides to perform a spray application at 8 km h−1 or higher, than nozzles with bigger orifices are recommended. Nevertheless, the proper selection of DC to obtain the defined adequate spray volumes, allowed obtaining less than 25% of over-sprayed leaves and guaranteed more than 80% and 75% of leaves with Nst higher than 30 and 70 stains cm−2 when insecticide and fungicides are applied, respectively, irrespective of FS (Fig. 11).

Fig. 11
figure 11

Dual y-axes charts illustrating the relationships between the percentage of not oversprayed WSP collectors (light-blue triangles-filled) and the percentage of WSP collectors characterized by a deposit density higher than a 30 stains cm−2 for insecticide treatment, or b 70 stains cm−2 for fungicide treatment (red pentagon-filled), with indication of the applied volume (l ha−1), shown separately for the different forward speeds. The vertical dashed black line represents the applied volume at which the curves intersect (Color figure online)

Conclusions

The PWM spray system was demonstrated an effective technology to apply variable rate spray application for precision agriculture in 3D crops like vineyards. It allowed the digital control of flow rate and spray droplet size from agricultural nozzles without concerns for possible under-sprayed canopy zones in the range of 30–100% duty cycle.

In particular, from the experimental results it can be concluded that:

  1. (1)

    Under field-controlled conditions, the on–off effect of the PWM system affects not only the variability of spray coverage measured along the sprayer travel direction, but also along the vertical spray profile. Even if the average spray coverage variability increases with increased forward speed, the magnitude of the duty cycle effect in enhaning the variability increases as the duty cycle decrease from 100 to 30%, irrespective of forward speed.

  2. (2)

    In contrast, under real field conditions, the on–off effect of the PWM system does not affect the uniformity of spray coverage measured within canopies at different depths and heights, neither did the adopted forward speed show a significant effect. In addition, the applied volume, a combination of different forward speeds and duty cycles, was fully reflected by the differences in both spray coverage and deposit density measured on the upper and lower leaf sides.

  3. (3)

    Furthermore, the relationships between spray coverage and deposit density allowed identification of the most suitable spray volumes for effective insecticide and fungicide spray applications in order to minimize the overspray and simultaneously maximize the desired deposit density according to the treatment specifications.

In general, the pulsing of the PWM valves has an effect on the spray coverage homogeneity, but this effect was not retrieved under real field conditions, most likely due to the interaction between leaves and sprayer airflow that moves the leaves and carries the spray droplets to the target canopy, and the large variation typical of field applications (e.g. due to the aforementioned air support, canopy density, etc.). Therefore, under real field conditions no concerns about possible under-sprayed canopy zones related to the use of the PWM system were noticed. Furthermore, the use of the PWM system gives farmers a wide range of options to obtain the most adequate spray application rate according to the treatment specifications without changing the spray pressure, and therefore the droplet size spectra produced, with expected benefits in terms of drift reduction.