Skip to main content
Log in

Development and deployment of 141Ce fiducial marker sources for supplementing nuclear diagnostic procedures

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

A facile method to prepare 141Ce based fiducial marker sources was developed to put forward an alternate to 99mTc markers routinely used during nuclear imaging procedures. Cerium oxide microspheres were prepared as source substrate by ‘internal gelation process’. ‘State-of- the art’ analyzing tools were used for characterizing the substrate. Neutron irradiation of microspheres in ‘Dhruva’ reactor was optimized. Post irradiation and quality evaluation, the sources were enclosed in an in-house developed portable device. 141Ce sources containing 37–59 MBq (1.0–1.6 mCi) of 141Ce were supplied to three nuclear imaging centres. Newly developed 141Ce fiducial markers could successfully supplement real time SPECT imaging procedures.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Wernick M, Aarsvold J (eds) (2004) Emission tomography. The fundamentals of PET and SPECT. Academic Press, San Diego

    Google Scholar 

  2. Gambhir SS, Yaghoubi SS (2010) Molecular imaging with reporter genes. Cambridge University Press, Cambridge, p 120

    Book  Google Scholar 

  3. Malpani B, Rakshit S, Saxena SK, Kumar Y, Menon B, Baghel NS, Banerjee S, Dash A (2017) Development of 141Ce point source as a surrogate for 99mTc-based markers in routine nuclear medicine imaging. Ind J Nucl Med 32:61

    Article  Google Scholar 

  4. Kumar M, Shyamala SG, Udhayakumar J, Dash A (2015) Development of 57Co pen pointer marker source for applications in nuclear medicine procedures. In: Proc. DAE-BRNS national symposium on nuclear and radiochemistry, Mumbai, India, pp 462–463

  5. Soltani Fatemeh, Samani Ali Bahrami, Sadeghi Mahdi, Arani Simindokht Shirvani, Yavari Kamal (2015) Production of cerium-141 using ceria and nanoceria powder: a potential radioisotope for simultaneous therapeutic and diagnostic applications. J Radioanal Nucl Chem 303:385–391

    Article  CAS  Google Scholar 

  6. Saxena SK, Yogendra Kumar B, Malpani S, Rakshit A Dash (2016) Development of a phantom and assessment of 141Ce as a surrogate radionuclide for flood field uniformity testing of gamma cameras. Appl Radiat Isot 112:115–121

    Article  CAS  Google Scholar 

  7. Saxena SK, Shanta A, Rajurkar NS, Majali MA (2006) Studies on the production and quality assurance of miniature 125I radioactive sources suitable for treatment of ocular and prostate cancers. Appl Radiat Isot 64:441–447

    Article  CAS  Google Scholar 

  8. Saxena Sanjay Kumar, Kumar Manoj, Yogendra Kumar J, Udhayakumar Usha Pandey, Dash Ashutosh (2013) Preparation on of 57Co point sources for the performance evaluation of nuclear imaging instruments. Appl Radiat Isot 79:12–17

    Article  CAS  Google Scholar 

  9. Saxena Sanjay Kumar, Kumar Yogendra, Dash Ashutosh (2012) Nafion/Zirconium phosphate composite membrane: a new approach to prepare P-32 patches for superficial brachytherapy applications. Cancer Biother Radio 27(4):276–284

    CAS  Google Scholar 

  10. Ashutosh Dash RN, Varma Ramu Ram, Saxena SK, Mathakar AR, Avhad BG, Sastry KVS, Sangurdekar PR, Venkatesh Meera (2009) Fabrication of cesium-137 brachytherapy sources using vitrification technology. Cancer Biother Radio. 24(4):489–502

    Google Scholar 

  11. Saxena SK, Kumar Y, Shaikh SH, Pandey U, Kumar SA, Dash A (2017) Preparation of radioactive skin patches using polyhydroxamic acid grafted cellulose films toward applications in treatment of superficial tumors. Cancer Biother Radio. 32(10):364–370

    CAS  Google Scholar 

  12. Saxena Sanjay Kumar, Yogendra Kumar KC, Jagadeesan Jitendra Nuwad, Bamankar YR, Dash Ashutosh (2015) Studies on the development of Yb-169 brachytherapy seeds: new generation brachytherapy sources for the management of cancer. Appl Radiat Isot 101:75–82

    Article  CAS  Google Scholar 

  13. Saxena Sanjay Kumar, Mukherjee Archana, Kumar Yogendra, Ramu Ram AS, Tapase Vivek J, Anand Ashutosh Dash (2014) Preparation and deployment of indigenous 125I-seeds for the treatment of prostate cancer: dawn of prostate brachytherapy in India. J Radioanal Nucl Chem 302:1237–1243

    Article  CAS  Google Scholar 

  14. Bamankar YR, Vittal Rao TV, Pai RV, Gupta NK, Radhakrishna J (2017) Preparation and characterization of CeO2 microspheres for their potential application in nuclear medicine diagnostic procedures. In: Proc. 13th DAE-BRNS symposium on nuclear and radiochemistry (NUCAR-2017), Bhuvaneshwar, Odissa, India, pp 540–541

  15. Brunauer S, Emmekte PH, Teller E (1938) Adsorption of gases in multimolecular layer. J Am Chem Soc 60:309–319

    Article  CAS  Google Scholar 

  16. Barratte EP, Joyner CG, Halende PP (1951) The determination of pore volume and area distributions in porous substances. I. Computations from nitrogen isotherms. J Am Chem Soc 73:373–380

    Article  Google Scholar 

  17. Saxena SK, Sharma SD, Muthe KP, Kumar Y, Dash A, Meera Venkatesh M (2008) Development of a new design I-125 brachytherapy seed for its application in the treatment of eye and prostate cancer. Cancer Biother Radio 23(6):807–818

    CAS  Google Scholar 

  18. Testing and Classification of Sealed Radioactive Sources (2001) AERB SS-3 (Rev-1). A publication of Atomic Energy Regulatory Board, India

  19. Rosslyn VA (2001) Performance measurements of scintillation cameras. NEMA standards publication (NU-1-2001). Global Engineering Documents, National Electrical Manufacturers Association (NEMA), Washington

    Google Scholar 

  20. Graham L, Stephen, Frederic HF (1995) Quantification of SPECT performance. AAPM report No.-52. American Association of Physics in Medicine (AAPM), pp 401–409

  21. IAEA (2009) Quality assurance for SPECT systems. Human Health Series No. - 6. International Atomic Energy Agency, Vienna, pp 46–52

    Google Scholar 

  22. Dash A, (Russ) Knapp FF Jr, Pillai MRA (2013) 99Mo/99mTc separation: an assessment of technology options. Nucl Med Biol 40:167–176

    Article  CAS  Google Scholar 

  23. Vittal Rao TV, Bamankar YR, Mukerjee SK, Aggarwal SK (2012) Preparation and characterization of Li2TiO3 pebbles by internal gelation sol-gel process. J Nucl Mater 426:102–108

    Article  CAS  Google Scholar 

  24. Vaidya VN, Mukerjee SK, Josgi JK, Kamat RV, Sood DD (1987) A study of chemical parameters of the internal gelation based sol-gel process for uranium dioxide. J Nucl Mater 148:324–331

    Article  CAS  Google Scholar 

  25. Raman S, Jurney ET, Starner JW, Lynn JE (1992) Thermal-neutron capture by silicon isotopes. Phys Rev 46(3):972

    CAS  Google Scholar 

  26. Saxena SK, Kumar Y, Bamankar YR, Sengupta A, Shukla R, Pandey U, Dash A (2019) Studies on the development of neutron activated 141Ce marker sources for their use during SPECT imaging procedures. In: Proceedings of 15th International conference on modern trends in activation analysis (MTAA-15) held at Mumbai, India, p 91

Download references

Acknowledgements

The authors are highly grateful to Dr. P.K. Pujari, Director, Radiochemistry & Isotope Group for his encouragement and support. Thanks are also due to Mr. B.G. Avhad and Mr. Pritam Bansode of our Division for providing engineering support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. K. Saxena.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Saxena, S.K., Kumar, Y., Bamankar, Y.R. et al. Development and deployment of 141Ce fiducial marker sources for supplementing nuclear diagnostic procedures. J Radioanal Nucl Chem 325, 893–904 (2020). https://doi.org/10.1007/s10967-020-07260-z

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-020-07260-z

Keywords

Navigation