1 Introduction

Quasi-millimeter waves and millimeter waves (MMWs) are prevalent in high-speed wireless communication, automobile collision prevention systems and high-resolution radar imaging. MMWs have come into widespread use in daily life, leading to increased public concerns about their possible health effects.

The necessity to evaluate the ocular effects of MMW exposure was first mentioned by Gandhi and Riazi in 1986 [1]. Although many studies have assessed the effects of microwave exposure on the eye, few studies have evaluated the specific effects of MMWs [2-6]. Frequency specific thresholds (MMW pulse wave) for ocular damage between 35 and 94 GHz were observed in rhesus monkey eyes, with the mean influence to develop corneal damage being 7.5 J/cm2 at 35 GHz and 5 J/cm2 at 94 GHz [4]. In rabbit eyes, 107 GHz effectively produced immediate stromal damage, which was generally gone by the next day, whereas the effects of 35 GHz were persistent and were almost always present the next day [2]. Taken together, these findings suggest that different frequencies have different ocular effects.

The depth of penetration of electromagnetic fields into an irradiated biological body has been shown to decrease as the frequency of the incident field is elevated [7]. Penetration depths of electromagnetic fields also depend on the electrical properties of the biological tissue. The anterior segment of the eye is a complicated structure, being comprised of tear film (3 layers), cornea (5 layers), the anterior chamber (with the aqueous humor circulation dependent on thermal properties), iris (with a 2.5-fold greater blood circulation than the brain [8]), and lens. Thus different wavelengths may have different effects on eye temperature. We have therefore investigated the effects of exposure to MMWs ranging between 18 and 40 GHz on ocular temperature changes in rabbit eyes.

2 Materials and Methods

2.1 Exposure system

Fig. 1 shows the exposure systems. Continuous waves of 18-26.5 GHz and 26.5-40 GHz were generated by an 83650B (Agilent Technologies, Santa Clara, CA, USA) MMW signal source, driving a 40 W TWT (18-26.5 GHz K band or 26.5-40 GHz Ka band, ETM Electromatic, Newark, CA, USA) amplifier. The signals were fed to a rectangular horn antenna (QRH-KRPS00, Quinstar, Torrance, CA, USA or 12A-26, MI Technologies, Suwanee, GA, USA) to expose rabbit eyes. Both forward and reverse powers were monitored to ensure the desired incident power densities (Fig. 1).

Fig. 1
figure 1

Block diagram of the MMW exposure system

Rabbit eyes were exposed to MMW of 200 mW/cm2 for 3 minutes at the distance of 200 mm (18-26.5 GHz) or 115 mm (26.5-40 GHz) from the antenna aperture to the corneal apex (Fig. 1). It was confirmed by an exploratory experiment that the corneal surface temperature of rabbit eye reached thermal balance by exposure for 3 minutes. The incident power densities were defined as the average value of φ 13 mm, which nearly corresponds to the surface of the rabbit cornea.

The center of the corneal surface was positioned on the line of the maximum radiation of the antenna. The exposure point (200 mm (18-26.5 GHz) or 115 mm (26.5-40 GHz) distance from the antenna surface to corneal apex) was set by red and green laser pointers on a target (Fig. 2A). After removal of the target, the apex of rabbit’s cornea was positioned at the exposure point (Fig. 2B).

Fig. 2
figure 2

Eye positioning system

Although our exposure system was not used for far-field conditions, the distributions of the incident power density were nearly uniform. The variation of the incident power densities at the area of φ 13 mm (similar size of cornea surface) was lower than 1dB for all frequencies used in this study.

2.2 Experimental animals

All animal experiments were conducted in accordance with the animal study guidelines established by Kanazawa Medical University (Kahoku, Japan) and the ARVO Statement for the Use of Animals in Ophthalmic and Vision Research [9].

Specific pathogen-free (SPF) pigmented male Dutch-belted rabbits of age 11-13 weeks and body mass 1.9-2.4 kg were purchased from Sankyo Lab Service (Toyama, Japan). They were kept in SPF cages with unrestricted access to sterilized food and ultraviolet-irradiated water. The eyes of each rabbit were examined with an SL-130 slit-lamp microscope (Zeiss, Tokyo, Japan) to ensure absence of abnormalities in the anterior segment and the image was recorded as the pre-exposure condition.

Each rabbit was immobilized using a lucite animal holder, specially constructed for this study, and injected intramuscularly with a solution containing 2 mg/kg of xylazine and 20 mg/kg of ketamine to induce general anesthesia. Immediately before MMW exposure, a 2% lidocaine hydrochloride topical anesthetic (Xylocaine 2%; AstraZeneca, Osaka, Japan) was administered to each eye. The upper and lower eyelids were retracted with tapes to keep the eyes open during MMW exposure. A cooling pad (Hiepita for Kids, Lion, Tokyo, Japan) was used to avoid heating the tissue surrounding the eyes.

Since anesthesia suppressed blinking, we administered 0.1% sodium hyaluronate (Hyaline Mini ophthalmic solution 0.1%; Santen Pharmaceutical, Osaka, Japan) eye drops, pre-warmed to 35-37 °C, as necessary to each eye to prevent corneal desiccation and the resulting damage to corneal epithelial cells; by pre-warming the eye drops, we minimized their effects on corneal temperature changes.

2.3 Ocular temperature measurements

Temperatures during MMW exposure were measured with a Fluoroptic Thermometer (Luxtron 790, Luxtron, Santa Clara, CA, USA), which was set up as described [10]. After both general and topical anesthesia, thermometer probes (0.5 mm in diameter) were inserted into the corneal stromal layer, lens nucleus and the center of vitreous, with the tip of each probe positioned at the center of the pupillary area. The thermometer probes were inserted under slit-lamp microscopy and their positions were checked by slit-lamp photography. After the corneal basal temperature stabilized, the topical anesthetic (warmed up to around 35-37 °C) was instilled into the conjunctival sac. The resulting corneal temperature drop down around 1 or 2 °C. Once the corneal temperature stabilized again, MMW exposure was started. The rabbit eyes were unilaterally and sequentially exposed to 200 mW/cm2 at 18 GHz, 22 GHz and 26.5 GHz or at 26.5 GHz, 35 GHz and 40 GHz, in ascending or descending order.

To improve the accuracy of measurement, the average of 3-5 ocular temperature measurements from one rabbit was considered as one measurement. To consider an animal’s individual specificity, 6-8 rabbits’ mean values were compared with each frequency. Room temperature and humidity during MMW exposure were maintained at 20-25 °C and 33-43% respectively, through air-conditioning.

2.4 Visualization of heat transportation in the anterior chamber

Microencapsulated thermochromic liquid crystals (MTLC, Japan Capsular Products, Tokyo, Japan) are 20-30 micrometer particles, the color of which changes as the surrounding temperature changes [11-13]. The coloration range of MTLC is 35 to 45 °C. They turn red at 35 °C, then yellow to green at just below to just above 39 °C, and blue at 42 °C. Using a 30 gauge injection needle and syringe, 0.2% MTLC was injected into the anterior chamber of each rabbit eye. The rabbit eyes were then unilaterally exposed to 200 mW/cm2 at 18 GHz or 40 GHz. A video camera was used to record aqueous convection and change in MTLC color in the anterior chamber.

2.5 Data analysis

Differences between outcomes of the K band (18-26.5 GHz) and Ka band (26.5-40 GHz) exposure systems were analyzed using Student’s two-tailed t-test, with a P value <0.05 considered statistically significant. The relation between ocular temperature elevation and frequency was analyzed using general linear mixed model (JMP® 7, SAS Institute, Tokyo, Japan).

3 Results

Fig. 3 shows the average ocular temperature changes after exposure of eyes to 200 mW/cm2 at 26.5 GHz using the two exposure systems. There were no statistical differences in the temperatures of the cornea, lens and vitreous using these two systems at the same wavelength. Since these ocular temperatures under exposure 26.5 GHz corresponded, we regarded further experimental data obtained from these 2 exposure systems as comparable.

Fig. 3
figure 3

Ocular temperature changes induced by the K and Ka band exposure systems at 26.5 GHz. NS indicates not significant difference

Fig. 4 shows temperature elevation by frequency (18, 22, 35, 40 GHz, averages of 6-8 rabbits: 26.5 GHz, average of 16 rabbits) during exposure to 200 mW/cm2 at 18 or 40 GHz. Elevation of the corneal temperature was the highest, followed by elevation of the lens temperature and then the vitreous temperature. In general, higher frequencies showed higher ocular temperature elevations (Trend: cornea (p<0.001), lens (p<0.003), vitreous (not significant)). Although all eyes were exposed to the same incident power density of MMWs, those exposed to 40 GHz had a 1.6-fold higher corneal temperature than those exposed to 18 GHz.

Fig. 4
figure 4

Temperature elevation during exposure to 200 mW/cm2 at 18 and 40 GHz (K and Ka band exposure systems)

Fig. 5 shows differences in time-course change of temperature in anterior chamber by 18 or 40 GHz. The area of the upper anterior chamber located between the cornea and iris showed an MTLC red-yellow color tone change 5 seconds after the start of 18 GHz 200 mW/cm2 exposure (Fig. 5A). In contrast, the upper part of the anterior chamber showed an MTLC red-yellow-green color tone change, and the lower part showed a green color tone change, 5 seconds after the start of 40 GHz 200 mW/cm2 exposure (Fig. 5D). MTLC color tone change by 18 GHz 200 mW/cm2 10 second exposure was seen only in the upper part of the anterior chamber, but MTLC color tone change by 40 GHz 200 mW/cm2 10 second exposure was seen in both upper and lower parts of the anterior chamber (Fig. 5B and 5E).

Fig. 5
figure 5

Temperatures of anterior chamber measurement by MTLC during MMW exposure. 18 GHz 200 mW/cm2: A: 5 seconds after the start of exposure, B: 10 seconds after the start of exposure, C: 30 seconds after the start of exposure. 40 GHz 200 mW/cm2: D: 5 seconds after the start of exposure, E: 10 seconds after the start of exposure, F: 30 seconds after the start of exposure

18 GHz 200 mW/cm2 30 seconds exposure caused an MTLC blue (over 42 °C) color tone change in the upper part of the anterior chamber and an MTLC green (around 39 °C) color tone change in the center and lower parts (Fig. 5C). In contrast, an MTLC blue (over 42 °C) color tone change was seen in the upper and lower of the anterior chamber exposed to 40 GHz (200 mW/cm2) 30 seconds after the start of exposure (Fig. 5F). MTLC color analysis revealed that although both eyes were exposed to the same incident power density of MMWs, 40 GHz exposure induces a higher temperature than does 18 GHz, in agreement with findings that 40 GHz had a 1.6-fold higher corneal temperature effect than that of 18 GHz in the cornea and lens temperature (Fig. 4).

Nevertheless, additional studies are needed to clarify the relationship between ocular heat transport and aqueous humor convection.

4 Discussion

The safety guidelines of the International Commission on Non Ionizing Radiation Protection [14] and the International Committee on Electromagnetic Safety (ICES) of the Institute of Electrical and Electromagnetic Engineers [15] are similar for exposures up to 300 GHz. Guidelines for MMWs are mainly based on the threshold of thermal sensations, but these guidelines are unclear when considering thermal effects on the eye.

Thermal ocular effects have been reported to differ under exposure to 35 GHz or 107 GHz MMWs [2]. Although both induced similar corneal damage immediately after exposure, the effects of exposure to 35 GHz continued longer than those of exposure to 107 GHz, a difference that may be due to wavelength specificity or relative biological effectiveness. In contrast, a comparison of the threshold of tissue damage between 35 and 94 GHz found that the higher frequency had a lower tissue damage threshold [4].

Depth of penetration of electromagnetic fields into an irradiated object decreases as the frequency of the incident field elevations [7]. Therefore, people believe that in the eye, higher frequencies penetrate only the surface of the cornea. Moreover, people believe that energy absorbed at the corneal surface (i.e., heat) can easily radiate in air. Indeed, ICNIRP guidelines indicate that the portion of the eye which absorbs very high frequencies (10 to 300 GHz) is the surface of the eye [14]. Hagan and Carpenter [16] compared cataractogenic potential between 2.45 GHz and 10 GHz and found that 2.45 GHz has greater cataractogenic potential than 10 GHz. The reason is consistent with knowledge of peak energy absorption, that the higher frequency (10 GHz) is absorbed at the outer surface of the eye and not in or near the lens.

To confirm the frequency specificity of quasi-MMW and MMW bands, we compared ocular temperatures during exposure to 200 mW/cm2 at 18, 22, 26.5, 35 and 40 GHz. In addition, we designed a method to measure transport of heat in the eye induced by quasi -MMW or MMW exposure.

The experimentally measured rabbit corneal temperature showed a temperature elevation during exposure. The experimental temperature measurements showed that a rise in frequency from 18 to 40 GHz created a higher temperature (Fig. 4). This is consistent with previous data about human skin warmth sensations [17].

The ocular temperature measurement during exposure from 18 to 40 GHz showed not only corneal temperature elevation, but also lens and vitreous humor temperature elevation during exposure (Fig. 4).

Temperature measurements in the anterior chamber by MTLC (although these measurements were semiquantitative) during MMW exposure showed that 40 GHz exposure induces a higher temperature than 18 GHz exposure in the anterior chamber. The color tone of MTLC on the surface of the crystalline lens 30 seconds after exposure start was almost the same as that directly under the cornea (Fig. 5C and 5F). The result of this MTLC experiment shows that heat by MMW exposure reached the crystalline lens. Examination by MTLC in non-exposed rabbit eye did not reveal such temperature differences indicating changes were due to MMW exposure and not intrinsic to rabbit eye. (Data not shown).

It is not yet clear whether the mechanism of intraocular heat transportation is conduction, transportation by aqueous humor convection, or both. It is clear, however, that quasi-MMW and MMW exposure induced heat is conveyed not only to the cornea but also the crystalline lens.

This phenomenon may suggest that aqueous humor convection has an important role in the heat transfer from the cornea to the lens or vitreous humor.

Karampatzakis and Samaras reported that aqueous humor flow in the anterior chamber had an important role in heat transfer using a 3D numerical model [18]. We need further study to clarify the relation between ocular heat conduction and aqueous humor convection.

We found the elevation in corneal, lens and vitreous temperature was associated with frequency. Our temperature measurement probe size is 0.5 mm and the wavelengths of MMW-band are several millimeter in the ocular tissue. The effects in temperature measurement due to field distortion caused by temperature probe insert might not be negligible. The results obtained in this study reflect the tendency for actual temperature elevations, although the measured temperatures may include some errors.

Further experiments are necessary to assess thermal transport in the eyeball because there are tear film layers at the front of the cornea and aqueous humor convection in the anterior chamber. The corneal surface is covered by a thin tear film, which protects the cornea from direct exposure to air, which can damage the corneal epithelium. The thermal effects of MMW exposure are likely more severe in the eyes of individuals with dry eye, whose tear film is much thinner and easier to penetrate, than in individuals with normal eyes. Since the prevalence of dry eye is very high and elevations with age, differences between dry and normal eyes should be considered in the assessment of the effects of MMWs in future work.

5 Conclusion

We have shown here that the elevation in ocular temperature in response to exposure to 200 mW/cm2 MMW is dependent on MMW frequency. Exposure to 40 GHz MMWs resulted in a 1.6-fold higher corneal temperature than exposure to 18 GHz MMWs. MMW exposure induced heat is conveyed not only to the cornea but also the crystalline lens. Further experiments are needed to elucidate the mechanism(s) underlying frequency-specific differences in ocular temperature elevations.