Analysis of the Reliability of Circuitries for A 20 kV Electrical Network

  • Published:
Power Technology and Engineering Aims and scope

Issues of increasing the reliability of power supply to a load of the first category by energizing consumers from two power sources are analyzed. Power-supply circuits of transformer substations of consumers from two geographically dispersed main substations through two mains with closed duplicate ring-circuit connection are considered. It is shown that with resistance neutral grounding, closed circuits prevent a short-term interruption of power supply in the event of an emergency disconnection of a section of the cable network.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. V. Mayorov, “Engineering and economic aspects of development of 20 kV electrical networks,” Élektroénergiya. Pered. Raspred., No. 4, 74 – 79 (2015).

  2. Electrical Installation Code [in Russian], Izd. NTs ÉNAS, Moscow (2007).

  3. Rules and Regulations SP 158.13330.2014. Buildings and Premises for Health Care Facilities. Design Rules [in Russian], appr. by order No. 58/pr of the Ministry of Construction, Housing, and Utilities of the Russian Federation of 2/18/2014.

  4. On Approvement of the Federal Air RegulationsRequirements to Airfields Intended for Take-off, Landing, Taxing, and Parking of Civil Aircraft” [in Russian], order No. 262 of the Ministry of Transport of the Russian Federation of 8/25/2015.

  5. A. V. Mayorov and A. A. Chelaznov, “Reliability of power supply to consumers in a 20 kV network,” Prom. Énerget., No. 3, 26 – 31 (2019).

  6. A. A. Fedorov (ed.), Handbook of Power Supply and Electrical Equipment. Vol. 1. Power Supply [in Russian], Énergoatomizdat, Moscow (1986).

  7. RD 34.20.185–94. Instruction on Design of City Electrical Networks [in Russian], appr. by Ministry of Energy of the Russian Federation 1/1/1995.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Yu. Lvov.

Additional information

Translated from Élektricheskie Stantsii, No. 8, August 2022, pp. 33 – 41. https://doi.org/10.34831/EP.2022.1093.8.005

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mayorov, A.V., Lvov, M.Y. & Chelaznov, A.A. Analysis of the Reliability of Circuitries for A 20 kV Electrical Network. Power Technol Eng 56, 771–778 (2023). https://doi.org/10.1007/s10749-023-01586-w

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-023-01586-w

Keywords

Navigation