Switching of High-Voltage Cable Lines with Shunt Reactors

  • Published:
Power Technology and Engineering Aims and scope

The problem of disconnecting high-voltage cable lines with shunt reactors by SF6 circuit breakers is discussed. In these schemes it is possible to have a significant aperiodic component of the circuit breaker current that can prevent opening of the breaker. The authors propose methods for application to cable transmission lines which they believe will be optimal for ensuring normal disconnects.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G. Evdokunin, M. Dmitriev, S. Goldshtein, and Yu. Ivanitskii, “High-voltage aerial transmission lines. Switching and effects on circuit breakers,” Novosti Élektrotekh., No. 3(51), (2008).

  2. M. V. Dmitriev, A. S. Karpov, E. B. Sheskin, A. G. Dolgopolov, and D. V. Kondratenko, Controlled Magnetized Shunt Reactors [in Russian], Rodnaya Ladoga, St. Petersburg (2013).

  3. M. V. Dmitriev, “Specifications for compensation of charge power in 500 – 750 kV transmission lines,” Novosti Élektrotekh., No. 5 (83), (2013).

  4. A. Yu. Vinogradov, A. S. Gerasimov, and A. V. Kozlov, “Use of control devices for compensation of reactive power in the unified power system of Russia for constructing a smart power system,” Izv. NTTs Edinoi Énerget. Sist., No. 69 (2013).

  5. P. M. Erokhin, V. G. Neuimin, A. S. Aleksandrov, and D. M. Maksimenko, “Modelling FACTS systems for calculating and optimizing power system operating regimes,” Izv. NTTs Edinoi Énerget. Sist., No. 66 (2012).

  6. Method for calculating and choosing means for ensuring disconnect of sulfur hexafluoride circuit breakers during switching of electrical transmission lines and aggregate buses equipped with shunt reactors [in Russian]. Appendix No. 1 to decree No. 838r of December 10, 2012, Federal Grid Company (2012).

  7. F. F. Da Silva, C. L. Bak, U. S. Gundmundsdottir, W. Wiechowski, and M. R. Knardrupgard, “Methods to minimize zero-missing phenomena,” IEEE Trans. Power Delivery, 25(4) (2010).

  8. A. Amatani, N. Nagaoka, Y. Baba, and T. Ohno, Power System Transients: Theory and Applications, CRC Press (2013).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to E. B. Sheskin.

Additional information

Translated from Élektricheskie Stantsii, No. 12, December 2015, pp. 37 – 43.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sheskin, E.B., Evdokunin, G.A. Switching of High-Voltage Cable Lines with Shunt Reactors. Power Technol Eng 50, 108–114 (2016). https://doi.org/10.1007/s10749-016-0669-8

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-016-0669-8

Keywords

Navigation