Abstract
Devices based on the method of absolute measurement of the level of higher harmonics in zerosequence currents of connections of a protected object are the most commonly used for protection from earth faults in compensated 6- to 10-kV cable networks of industrial and urban power-supply systems. However, many years of operating experience have shown that the technical refinement (the selectivity and the sensitivity) of overcurrent protection from earth faults based on the method of absolute measurement of higher harmonics is not always sufficient. One of the reasons for the low technical refinement of these protection devices is the inaccuracy in estimating the maximum and minimum possible higher harmonics levels in the earth-fault current of compensated 6- to 10-kV cable networks, which are required for the selection of the operating current settings and the sensitivity determination. The main factors influencing the maximum and minimum higher harmonics levels in the earth-fault current and their ratio were revealed on the basis of the computational experiments using the imitation models for 6- to 10-kV cable networks, the limiting values of these levels were determined, an determination of the harmonics-level instability in the fault current for cable networks with different total load compositions was given, and its interrelation with the fluctuations of the total coefficient of harmonic voltage components on 6- to 10-kV buses of network power centers was established. The conditions of applicability and the area of application of overcurrent protection from this type of failure based on the use of higher harmonics of the zero-sequence current for different objects of 6- to 10-kV compensated cable networks were determined taking into account the above estimates. Specifications for a method for selecting the operating current settings were proposed.
Similar content being viewed by others
References
Kiskachi, V.M. and Nazarov, Yu.G., Signaling of single- phase earth faults in compensated 6–10 kV cabling networks, Tr. Vses. Nauchno-Issled. Inst. Elektroenerg., 1963, no. 16.
Kiskachi, V.M., Surtseva, S.E., Georshenina, N.M., et al., Earth-fault signaling devices in 6–10 kV cabling network, Elektr. Stn., 1972, no. 4.
Borukhman, V.A., The operation of selective earth fault protection in 6–10 kV cabling networks and their improvement, Energetik, 2000, no. 1.
Zhezhelenko, I.V., Vysshie garmoniki v sistemakh elektrosnabzheniya prompredpriyatii (Higher Harmonics in the Power Supply Systems of Industrial Enterprises), Moscow: Energoatomizdat, 2000.
Kiskachi, V.M., Selectivity of earth fault signaling using higher harmonics of residual currents, Elektrichestvo, 1967, no. 9.
Pravila ustroistva elektroustanovok (PUE) (Rules of the Installations of Electrical Installations), Moscow: Omega-L, 2012, 7th ed.
Dobryagina, O.A., Shagurina, E.S., and Shuin, V.A., Effect of transient processes in earth faults in mediumvoltage electrical installations on the functions of earthfault protection based on higher harmonics, Releinaya Zashch. Avtom., 2012, no. 2.
RD 153-34.0-20.527-98. Rukovodyashchie ukazaniya po raschetu tokov korotkogo zamykaniya i vyboru elektrooborudovaniya (RD 153-34.0-20.527-98. Manual for Calculation of Short-Circuit Currents and Selection of Electrical Equipment), Moscow: Enas, 2002.
Spravochnik po proektirovaniyu elektricheskikh setei (Handbook on Engineering of Electrical Networks), Faibisovich, D.L., Ed., Moscow: Enas, 2012.
Shadrikova, T.Yu., Development of complex multifunctional protection from single-phase earth faults of 6–10 kV cable networks, Cand. Sci. (Tech.) Dissertation, Ivanovo, 2016.
Vainshtein, V.L., Analysis of higher harmonics of the earth fault current, Prom. Energ., 1986, no. 1.
Kiskachi, V.M., Calculation of the minimum level of higher harmonics in single-phase earth faults in power networks with isolated and compensated neutral, Tr. Vses. Nauchno-Issled. Inst. Elektroenerg., 1966, no. 26.
Zhezhelenko, I.V. and Tolpygo, O.B., Sensitivity of earth fault signaling using higher harmonics in industrial power networks, Elektrichestvo, 1969, no. 10.
Alekseev, V.G., Current protection of ZGNP-4.2 from earth faults in the stator winding of a generator operating on bus rods, Elektr. Stn., 2006, no. 2.
Shuin, V.A. and Gusenkov, A.V., Zashchity ot zamykanii na zemlyu v elektricheskikh setyakh 6–10 kV (Protection against Earth Faults in 6–10 kV Electrical Networks), Moscow: Energoprogress, 2001.
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © V.A. Shuin, V.A. Martynov, E.S. Shagurina, T.Yu. Shadrikova, 2018, published in Elektrotekhnika, 2018, No. 1, pp. 62–72.
About this article
Cite this article
Shuin, V.A., Martynov, V.A., Shagurina, E.S. et al. Overcurrent Protection from Earth Faults Based on Higher Harmonics for Compensated 6- to 10-kV Cable Networks. Russ. Electr. Engin. 89, 54–63 (2018). https://doi.org/10.3103/S1068371218010133
Received:
Published:
Issue Date:
DOI: https://doi.org/10.3103/S1068371218010133