Abstract
This paper reports on the study of a piezoelectric actuated micropump with integrated elastomeric check valves that can transport small amounts of fluid in a highly controllable manner. The proposed micropump consists of a piezoelectric actuated fluid chamber with two integrated elastomeric check valves for regulating input and output flow direction, while restricting backflows. The actuation, fluid dynamic response and fluid–structure interactions at various working cycles are studied through a fully coupled multiphysics simulation (solid mechanics, electrostatic and fluid flow). The pump bodies are manufactured by micromachining of PMMA sheets, while the middle elastomeric membrane and diaphragm are fabricated by spin-coating PDMS. The experimental results confirm that the micropump can provide sufficiently low-velocity outflow for biomedical applications between 3.4 – 41.8 µl/min. The performance of the micropump is improved significantly through a convenient geometric modification of an off-the-shelf piezoelectric brass disc. Furthermore, the combination of this micropump with the 3D cell-culture microfluidic chip realizes the dynamic culture of cells encapsulated in 3D hydrogels with a continuous flowing medium, which offers the potential for changing the traditional mode of 3D cell culture with a static supply of nutrition and factors.
Graphical abstract
Similar content being viewed by others
References
D. Accoto, M.C. Carrozza, P. Dario, J. Micromech. Microeng. 10, 277 (2000). https://doi.org/10.1088/0960-1317/10/2/329
F. Amirouche, Y. Zhou, T. Johnson, Microsyst. Technol. 15, 647 (2009). https://doi.org/10.1007/s00542-009-0804-7
R. Ardito, E. Bertarelli, A. Corigliano, G. Gafforelli, Compos. Struct. 99, 231 (2013). https://doi.org/10.1016/j.compstruct.2012.11.041
A.K. Au, H. Lai, B.R. Utela, A. Folch, Micromachines 2, 179 (2011). https://doi.org/10.3390/mi2020179
H.G. BettaswamyGowda, U. Wallrabe, Micromachines 10, 797 (2019). https://doi.org/10.3390/mi10120797
G. Bui, J.-H. Wang, J.-L. Lin, Micromachines 9, 1 (2017). https://doi.org/10.3390/mi9010001
P.-H. Cazorla, O. Fuchs, M. Cochet, S. Maubert, G. Le Rhun, P. Robert, Y. Fouillet, E. Defay, Procedia Eng. 87, 488 (2014). https://doi.org/10.1016/j.proeng.2014.11.402
P.-H. Cazorla, O. Fuchs, M. Cochet, S. Maubert, G. Le Rhun, Y. Fouillet, E. Defay, Sens. Actuators Phys. 250, 35 (2016). https://doi.org/10.1016/j.sna.2016.09.012
C.-H. Cheng, Y.-P. Tseng, Microsyst. Technol. 19, 1707 (2013). https://doi.org/10.1007/s00542-013-1857-1
A. Choi, S. L. Vatanabe, C. R. de Lima, and E. C. N. Silva, A low cost piezoelectric valve-less diaphragm pump. (ABCM Symposium Series in Mechatronics, 2009) https://abcm.org.br/symposiumseries/SSM_Vol4/Section_VII_SENSORS_AND_ACTUATORS/SSM4_VII_12.pdf. Accessed 10 May 2022
A.J. Conde, A. Bianchetti, F.E. Veiras, A. Federico, J.M. Cabaleiro, M. Dufva, R.E. Madrid, L. Fraigi, RSC Adv. 5, 49996 (2015). https://doi.org/10.1039/C5RA08819D
A. Corigliano, R. Ardito, C. Comi, A. Frangi, A. Ghisi, and S. Marian, Micropumps, in Mech. Microsyst, eds A. Corigliano, R. Ardito, C. Comi, A. Frangi, A. Ghisi and S. Marian (John Wiley & Sons, Ltd, Chichester, UK, 2018), pp. 185–204. https://doi.org/10.1002/9781119053828.ch10
J.S. Dong, R.G. Liu, W.S. Liu, Q.Q. Chen, Y. Yang, Y. Wu, Z.G. Yang, B.S. Lin, Sens. Actuators Phys. 257, 165 (2017). https://doi.org/10.1016/j.sna.2017.02.001
J. Dong, Y. Cao, Q. Chen, Y. Wu, R.G. Liu, W. Liu, Y. Yang, Z. Yang, J. Intell. Mater. Syst. Struct. 31, 117 (2020). https://doi.org/10.1177/1045389X19880024
S.A.F. FarshchiYazdi, A. Corigliano, R. Ardito, Micromachines 10, 259 (2019). https://doi.org/10.3390/mi10040259
G.-H. Feng, E.S. Kim, J. Micromech Microeng 14, 429 (2004). https://doi.org/10.1088/0960-1317/14/4/001
G.-H. Feng, E.S. Kim, J. Microelectromechanical Syst. 14, 192 (2005). https://doi.org/10.1109/JMEMS.2004.839331
H. Geckil, F. Xu, X. Zhang, S. Moon, U. Demirci, Nanomed. 5, 469 (2010). https://doi.org/10.2217/nnm.10.12
R.R. Gidde, P.M. Pawar, V.P. Dhamgaye, Microsyst. Technol. (2019). https://doi.org/10.1007/s00542-019-04535-8
N.J. Graf, M.T. Bowser, Lab. Chip 8, 1664 (2008). https://doi.org/10.1039/B805252B
L. He, X. Wu, D. Zhao, W. Li, G. Cheng, S. Chen, Microsyst. Technol. 26, 609 (2020). https://doi.org/10.1007/s00542-019-04553-6
B.D. Iverson, S.V. Garimella, Microfluid. Nanofluidics 5, 145 (2008). https://doi.org/10.1007/s10404-008-0266-8
O.C. Jeong, S. Konishi, Sens. Actuators Phys. 135, 849 (2007). https://doi.org/10.1016/j.sna.2006.09.012
O.C. Jeong, S.S. Yang, Sens. Actuators Phys. 83, 249 (2000). https://doi.org/10.1016/S0924-4247(99)00392-1
M. Koch, N. Harris, A.G.R. Evans, N.M. White, A. Brunnschweiler, Sens. Actuators Phys. 70, 98 (1998). https://doi.org/10.1016/S0924-4247(98)00120-4
W. Li, T. Chen, Z. Chen, P. Fei, Z. Yu, Y. Pang, Y. Huang, Lab. Chip 12, 1587 (2012). https://doi.org/10.1039/c2lc40125h
Y. Luo, M. Lu, T. Cui, Microsyst. Technol. 17, 403 (2011). https://doi.org/10.1007/s00542-010-1199-1
H.K. Ma, B.R. Hou, H.Y. Wu, C.Y. Lin, J.J. Gao, M.C. Kou, Microsyst. Technol. 14, 1001 (2008). https://doi.org/10.1007/s00542-007-0462-6
H.K. Ma, R.H. Chen, N.S. Yu, Y.H. Hsu, Sens. Actuators Phys. 251, 108 (2016). https://doi.org/10.1016/j.sna.2016.10.010
G. Massimino, A. Colombo, R. Ardito, F. Quaglia, A. Corigliano, Extreme Mech. Lett. 40, 100968 (2020). https://doi.org/10.1016/j.eml.2020.100968
B. Mosadegh, C.-H. Kuo, Y.-C. Tung, Y. Torisawa, T. Bersano-Begey, H. Tavana, S. Takayama, Nat. Phys. 6, 433 (2010). https://doi.org/10.1038/nphys1637
Y.H. Mu, N.P. Hung, K.A. Ngoi, Int. J. Adv. Manuf. Technol. 15, 573 (1999). https://doi.org/10.1007/s001700050104
F. Munas, G. Melroy, C. Abeynayake, H. Chathuranga, R. Amarasinghe, P. Kumarage, V. Dau, D. Dao, Sensors 18, 1302 (2018). https://doi.org/10.3390/s18051302
Nguyen, J Fluids Eng 124, 384 (2002). https://doi.org/10.1115/1.1459075
N.-T. Nguyen, T.-Q. Truong, Sens. Actuators B Chem. 97, 137 (2004). https://doi.org/10.1016/S0925-4005(03)00521-5
T. Peng, Q. Guo, J. Yang, J. Xiao, H. Wang, Y. Lou, X. Liang, Sens. Actuators B Chem. 301, 126961 (2019). https://doi.org/10.1016/j.snb.2019.126961
C. Qian, S. Chen, J. Wang, J. Kan, Z. Zhang, M. Yu, Sens. Actuators Phys. 306, 111962 (2020). https://doi.org/10.1016/j.sna.2020.111962
Y.J. Ren, Y.T. Ma, D. Huang, J. Chen, Z.H. Feng, Sens. Actuators Phys. 244, 126 (2016). https://doi.org/10.1016/j.sna.2016.04.026
M.T.A. Saif, B.E. Alaca, H. Sehitoglu, J. Microelectromech Syst. 8, 335 (1999). https://doi.org/10.1109/84.788638
M. Shen, C. Yamahata, M.A.M. Gijs, Microelectron. Eng. 85, 1104 (2008). https://doi.org/10.1016/j.mee.2007.12.013
S. Singh, N. Kumar, D. George, A.K. Sen, Sens. Actuators Phys. 225, 81 (2015). https://doi.org/10.1016/j.sna.2015.02.012
E. Stemme, G. Stemme, Sens. Actuators Phys. 39, 159 (1993). https://doi.org/10.1016/0924-4247(93)80213-Z
T.-Q. Truong, N.-T. Nguyen, J. Micromech Microeng 14, 632 (2004). https://doi.org/10.1088/0960-1317/14/4/026
T.T. Veenstra, J.W. Berenschot, J.G.E. Gardeniers, R.G.P. Sanders, M.C. Elwenspoek, A. van den Berg, J. Electrochem. Soc. 148, G68 (2001). https://doi.org/10.1149/1.1339873
T. T. Veenstra, MAFIAS: An Integrated Lab-on-a-Chip for Ammonium Measurement. (Universiy of Twente, 2001), https://ris.utwente.nl/ws/portalfiles/portal/6039213/thesis_Veenstra.pdf. Accessed 06 July 2022
Y.-N. Wang, L.-M. Fu, Microelectron. Eng. 195, 121 (2018). https://doi.org/10.1016/j.mee.2018.04.008
X.Y. Wang, Y.T. Ma, G.Y. Yan, D. Huang, Z.H. Feng, Sens. Actuators Phys. 218, 94 (2014). https://doi.org/10.1016/j.sna.2014.07.026
Z. Wang, X. Zhu, X. Cong, Biofabrication 13, 035051 (2021). https://doi.org/10.1088/1758-5090/ac0982
P. Woias, Sens. Actuators B Chem. 105, 28 (2005). https://doi.org/10.1016/S0925-4005(04)00108-X
X. Yang, Z. Zhou, H. Cho, X. Luo, Sens. Actuators Phys. 130–131, 531 (2006). https://doi.org/10.1016/j.sna.2005.12.021
P. Zeng, L. Li, J. Dong, G. Cheng, J. Kan, F. Xu, Proc Inst Mech Eng Part C J Mech Eng Sci. 230, 2339 (2016). https://doi.org/10.1177/0954406215596357
Z. Zhang, J. Kan, S. Wang, H. Wang, J. Ma, Y. Jiang, Chin. J. Mech. Eng. 28, 954 (2015). https://doi.org/10.3901/CJME.2015.0411.043
B. Zhang, Y. Huang, L. He, Q. Xu, G. Cheng, Sens. Actuators Phys. 302, 111785 (2020). https://doi.org/10.1016/j.sna.2019.111785
Y. Zhou, F. Amirouche, Micromachines 2, 345 (2011). https://doi.org/10.3390/mi2030345
X. Zhu and Z. Wang, Self-Organized 3D Tissue Patterns: Fundamentals, Design, and Experiments (CRC Press, 2022).
Acknowledgements
This research was funded by the National Natural Science Foundation of China (grant number 51875170), Fundamental Research Funds for the Central Universities of China (grant numbers B200202225), and Changzhou Sci &Tech Program (grant number CE20195037).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interest
The authors report no declarations of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Holman, J.B., Zhu, X. & Cheng, H. Piezoelectric micropump with integrated elastomeric check valves: design, performance characterization and primary application for 3D cell culture. Biomed Microdevices 25, 5 (2023). https://doi.org/10.1007/s10544-022-00645-9
Accepted:
Published:
DOI: https://doi.org/10.1007/s10544-022-00645-9