1 Introduction

Over the last two decades, microfluidic systems have witnessed a rise in their applications in life sciences, chemistry and diagnostics (Duncombe et al. 2015; Elvira et al. 2013; Sackmann et al. 2014). Microfluidics offers enhanced fluidic control and precision over metering and monitoring. Soft lithographic methods (Xia et al. 1998) have made microfluidic devices more and more accessible to the end users.

Capillary action is the spontaneous movement of fluid on the surface of a solid material due to surface energy minimization. Capillary-driven systems allow even complex fluidics operations to be programmed on the chip by designing the geometry and the surface energy of the chip (Juncker et al. 2002; Safavieh and Juncker 2013; Mosadegh et al. 2010). Among physical parameters used to characterize capillary filling of microchannels, contact angle (CA) on the open surface in a three-phase system and capillary filling dynamics in closed micro-geometries are the most widely used (de Gennes 2004).

Microfluidic chips are nowadays most commonly made from polymer materials due to their ease of processability, low cost of fabrication and ability to conformally replicate any premade micro- and nano-structures. The most widely used polymer for microfluidics, poly (dimethylsiloxane) (PDMS) is inherently hydrophobic. In fact, most of the available polymers have either hydrophobic or only slightly hydrophilic surface chemistries, which provide insufficient capillary pressure for capillary driven systems.

Because of this, a multitude of methods have been employed to render hydrophilic properties onto these surfaces to enable bio- and capillary filling-based applications (Ferreira et al. 2015; Yoshida et al. 2013; Tsougeni et al. 2009; Khorasani et al. 2008; Vlachopoulou et al. 2009; Tan et al. 2010). Plasma treatments are a widely used technique to increase the surface energy of polymers (Tan et al. 2010; Jokinen and Franssila 2008). However, a near universal observation is a hydrophobic recovery that partially or completely negates the effect of the plasma hydrophilization over time (Owen and Smith 1994; Jokinen et al. 2012).

In general, three mechanisms have been proposed to contribute to hydrophobic recovery of PDMS: Bulk to surface migration of the low molecular weight species (LMW) (Toth et al. 1994; Hillborg et al. 2000, 2004), surface re-structuring phenomena including re-orientation of hydroxyl groups toward bulk due to energetically unfavorable arrangement and condensation of silanol groups on the surface (Morra et al. 1990; Bacharouche et al. 2013), and generation of LMW species within the surface during the plasma treatment (Toth et al. 1994; Kim et al. 1999, 2001a, b). Process parameters which significantly influence the contribution of such mechanisms include pre-polymer composition, curing temperature and time, sample thickness, vacuum treatment, plasma treatment parameters, post-plasma modifications and sample storage conditions (Nguyen 2014). Numerous efforts have been conducted on reducing, if not completely eliminating, the recovery over time by focusing on one of those process parameters.

Eddington et al. (2006) reduced the recovery rate by reducing the primary cause of it, i.e., removing free oligomers, through polymerizing uncrosslinked monomers by means of extended thermal aging of the PDMS. Solvent extraction by heptane prior to plasma introduction rendered a 5 wt% weight loss of PDMS samples (Lee et al. 2003) and led to reduced hydrophobic recovery for a week when stored in air at room temperature (Vickers et al. 2006). Nguyan et al. (2014) examined the effect of the prepolymer composition on durability of hydrophilization. By removing cyclic dimethylsiloxane groups (predominant LMW moieties responsible for recovery) from the mix through extended room temperature curing and longer vacuum steps of 40 min prior to plasma treatment, they achieved low dynamic contact angles of θA/θR = 51°–56°/38°–43° on silicones measured more than 30 days after the plasma treatments. Hemmilä et al. (2012) studied the effect of various surface treatments on PDMS by plasma-activated physisorption, grafting to-and-from with biocompatible HEMA, PEG and PVA polymer brushes and could retain hydrophilicity of some of the samples up to 6 months. By introducing a plasma-activated two-step grafting of PEG polymer brushes, Delamarche et al. (2003) achieved hydrophilic stability of PDMS stamps suitable for micro-contacting printing (µCP) of polar inks. Layer-by-layer (LbL) deposition of counterions in a sequential manner on freshly oxidized PDMS has also been employed for stable hydrophilization of the microfluidics toward droplet generation (hexadecane in water) which maintained droplet generation ability up to 5 months (though no capillary data available) (Bauer et al. 2010). Storage of samples in polar solvents (deionized water and Luria–Bertani broth) has been shown to postpone recovery up to a week as hydrophilic surface groups energetically favor retaining the surface position (Zhao et al. 2012). Bulk modification of the PDMS with amphiphilic surfactant PEO poly(dimethylsiloxane-ethylene oxide polymeric) has been shown to impart a tunable hydrophilicity (21.5°–80.9°) ratio up to 2 months with a consequent fade away (Yao and Fang 2012). A two-step process including UV treatment of PDMS combined with PVA surface coating after plasma treatment (Bodas and Khan-Malek 2006) allowed recovery of contact angle up to 70° in 2 weeks. Solvent extraction by trimethylamine, ethyl acetate and acetone in sequence (Vickers et al. 2006) maintained contact angles of 30°–40° up to a week. Preservation of hydrophilic surfaces in the presence of polar liquids (Ren et al. 2001) led to maintenance of electroosmotic flow after 14 days by immersion in water. Surface nanotexturing of PDMS by a two-step process of SF6 and O2 plasma in a sequential manner has also been explored and holds potential for maintaining hydrophilicity for up to 7 days (Vlachopoulou et al. 2009).

In the works discussed above, the sought after prolonged hydrophilization requires a physical or chemical intervention with footprints that might not be desirable for intended applications, commonly requiring a post processing step after hydrophilization. In this report, we show the hydrophilic state of PDMS can be maintained long term without a need of any invasive chemical and physical steps after the hydrophilization. Diffusion to and from surface, and reorientation of surface polar groups toward bulk are known as key mechanisms responsible for surface restructuring and hydrophobic recovery (Kim et al. 2001a, b). Leveraging the temperature dependency of the main recovery mechanisms, we demonstrate the superhydrophilicity of PDMS remains at least after 100 days by storing the samples in a sufficiently cold temperature. Freshly plasma-hydrophilized chips are stored in − 80 °C, − 15 °C and room temperature (RT), and it is demonstrated that increasingly colder storage temperatures lead to significant retainment of the contact angle, capillary filling rate, and the ability of capillary flow to bypass geometrical obstacles in microchannels. These characteristic parameters are shown to correlate with surface chemistry, i.e., presence of O2 plasma-induced hydroxyl groups recorded by ATR-FTIR time-series measurement of the samples during the recovery.

2 Materials and methods

2.1 PDMS fabrication

PDMS sheets used for the sessile droplet goniometry measurements were prepared from Sylgard 184, Dow Corning by mixing a 10:1 ratio of monomer to crosslinking agent, degassing and planarizing prepolymer to 3-mm thickness in a polystyrene petri dish. The samples were cured in an oven at 70 °C for 2 h and cut to test pieces of 2 cm2. Cleaning step was performed by immersing the PDMS pieces in isopropylalcohol (IPA) and sonicating for 45 min, rinsed with DI water, dried by nitrogen gun and degassed in a fume hood overnight to remove absorbed IPA. Finally, the pieces were thermally aged in an oven at 100 °C for 51 h.

The capillary filling experiments were made with PDMS microfluidic chips. The PDMS chips were made by replication molding from SU-8 masters. The SU-8 masters were made by spin coating SU-8 50 (Microchem) 2050 rpm 45 s, soft bake on a hotplate at 95 °C for 5 min, UV exposure by mask aligner (model MA-6, SÜSS MICROTEC AG) for 10 s, and post exposure bake at 95 °C for 10 min. PDMS was cast and cured with the same parameters as for the PDMS sheets. Flat sheets of 3-mm-thick PDMS as substrates for the channels, were likewise prepared in flat petri dishes. After curing, the chips were cut by a surgical grade blade and inlet and outlets were punched into the chips. Cleaning and thermal aging of the chips and substrates were carried identically to the PDMS sheets. The chips and the sheets were both exposed to oxygen plasma and afterwards placed in contact with each other to bond them covalently.

2.2 Plasma treatment

Plasma treatment of the PDMS sample sheets and microfluidic capillary chips was performed by Plasma System 400 batch reactor (PVA Tepla AG). Microwave power of 50 W (2.45 GHz) was used to generate the plasma. Oxygen flow was set to 500 ml/min and the treatment time was 2 min.

2.3 Cold storage

Individual PDMS sheets and microfluidic chips were stored in separate small petri dishes, divided into three equal batches, each of which to be maintained at a different storage temperatures (RT, − 15 °C and − 80 °C). For each data point reported in CAs at a given temperature, two sheets with three measurements on each were used and average CA and combined variance were reported as the standard deviation. In the capillary filling kinetics measurements, three batches of microchannel chips were prepared, each stored at a different temperature. For each of the reported data points representing a Washburn’s constant (and corresponding calculated dynamic CA), a video recording of filling one complete channel at a specific day was acquired. For infrared vibrational spectroscopy experiments, for each data point on the results, three samples were measured and averaged over values. Geometrical valve measurements include three identical batches stored at three different temperatures. Each experiment involves the video recording of filling of one channel with five consecutive valves (increasing angle of widening) and results are reported as binary passage or not passage through valves at different days. A household refrigerator-freezer (Bauknecht) was used for − 15 °C storage and a laboratory freezer (Thermo, Electron Corporation) was used for storage at − 80 °C. The samples were individually stored at the designated temperature in closed petri dishes until they were used in measurements. All samples did not spend time in room temperature air for longer than 30 min, to minimize the thermal effects. Samples were thermalized to RT before measurements by ambient exposure.

2.4 Contact angle measurement

Advancing and receding contact angles were measured by the sessile droplet method (Theta, Attension). The droplet rate was 0.1 µl/s and the advancing and receding angles were measured between droplet sizes 2 µl and 10 µl. The data points reported are the averages of six measurements (2 different sheets prepared with the same parameters and three points per sheet) with standard deviations calculated from combined variances. In cases where the determination of advancing or receding contact angles was not possible due to them being too low to be measured by sessile droplet goniometry, they were counted as 5° in the results.

2.5 Capillary filling rate experiment

A meandering microchannel with extended straight sections (width 100 µm, height 51 µm, total length 10 cm) was utilized in the capillary filling rate experiments. A batch of PDMS microchannel chips were stored in each of the storage temperatures. For each of the data points on the results, a single chip was taken out of the storage for measurements at designated days during a 2-week span. Capillary filling experiments were performed by pipetting 10 μl of a mixture of water and food dye into the inlet, and recording a video of the filling process. The capillary filling rate was determined from these videos. During each filling experiments, a new timepoint was registered every time meniscus proceeded additional 10 mm. The distance was measured by microfabricated markers on the chip (every 10 mm). The experiment was a time series with a single data point for each storage temperature and each timepoint.

2.6 Geometrical valve experiment

A straight microchannel (width 100 µm, height 51 µm, length 2 cm) with five sequential and axisymmetric geometrical widenings in the horizontal plane was used for testing the ability of capillary flow to bypass local geometrical barriers. The widening angles on each side of channel from smallest to biggest include 10°, 40°, 60°, 80° and 90°. Geometrical barrier passage experiments were performed by pipetting 10 μl of a mixture of water and food dye into the inlet and recording a video of the filling process. The passage of the liquid through the barriers was determined from these videos as a binary decision. The results are based on a single sample per storage temperature and timepoint.

2.7 ATR-FTIR

An Attenuated Total Reflection Fourier Transformed Infrared apparatus, Spectrum Two® Perking Elmer with KBr windows for data collection was used for surface analysis. Spectral range of 4000–350 cm−1 at resolution of 4 cm−1 and four scans were used. A broad peak at around 3000–3500 cm−1 as a telltale of the OH bond vibrations (Bodas and Khan-Malek 2006) was selected for characterizing the hydrophilization and hydrophobic recovery. After the plasma treatment, the samples were tracked over 2 months. All OH peak heights were measured against their respective flat region in pristine PDMS (3000–3500 cm−1) and normalized to the first (highest peak) data point to highlight the relative strength of the signal on a particular point in time. Three identical samples were used for each peak measurement at a specific timepoint and temperature, and the average value of peak intensity was utilized for analysis to increase the statistical significance of the result. The plasma treatment duration applied to samples analyzed by ATR-FTIR was longer and about 30 min, compared to the plasma time used for the contact angles and capillary filling measurements. The reason for this choice was that the 2-min treatment time did not produce a strong enough signal to be reliably detected by ART-FTIR.

3 Results and discussion

3.1 Hydrophilization and hydrophobic recovery—PDMS sheets

The resulting rate of hydrophobic recovery of plasma-exposed PDMS sheets stored at three different temperatures from the onset of hydrophilization up to 100 days for both the advancing and receding contact angles is shown, respectively in Fig. 1a, b. The contact angle of the samples stored in different temperatures separates clearly into three distinct trajectories over the span of 100 days. The − 80 °C samples kept a steady cosine values of close to 1, samples kept in − 15 °C followed a gradual drop to 0.6 and samples kept at RT reached a near 0 value for advancing CAs by the end of the 100 days. The native PDMS showed an advancing cosine value of − 0.52 (θadv of 122° ± 7°) and for receding cosine 0.01 (contact angle of 89° ± 2°). Immediately after the treatment, the PDMS became superhydrophilic corresponding to 0.99 in cosine value (advancing contact angle 7° ± 6° and receding contact angle 5° ± 2°). The sample stored in the room temperature recovered to approximately cosine value of 0.77/0.84 (contact angle θavd 40°/θRec 33°) in a day, 0.36/0.5 (θadv 69°/θRec 60°) in a week and had a near full recovery to − 0.14 and 0.28 (θadv 98°/θRec 74°) over 100 days. The sample stored at − 15 °C recovered to approximately 0.85/0.93 (θadv 32°/θRec 21°) in a day, 0.72/0.83 (θadv 44°/θRec 34°) in a week and settled to 0.56/0.46 (θadv 56°/θRec 46°) over 100 days. The sample stored at − 80 °C remained very hydrophilic throughout the experiment. For contact angles of most test pieces stored at − 80 °C the cosine values were more than 0.97 (less than CA 15°) throughout the experiment. Few of the data points have a large standard deviation. Experimental artefacts such as local heterogeneities of plasma treatment and surface contamination can be the origin of such large variations. However, the overall trends in both the advancing and receding contact angles are very clear.

Fig. 1
figure 1

Hydrophobic recovery of plasma-treated PDMS sheets as a function of storage temperature for advancing contact angle (left plot) and receding contact angle (right). Each data point is the average ± of the combined variance of 3–6 measurements performed on two samples. The trend lines represent a kinetic recovery of diffusion and reorientation model, fitted against data, and further elaborated in the Eq. 1

A time-dependent model for hydrophobic recovery of polymers accounting for both LMW species diffusion and surface bound rotations, Diffusion and Rotation (D&R) (Mortazavi and Nosonovsky 2012) is used to fit the data by a nonlinear least square solver in Matlab and is overlayed in Fig. 1. The full model accounts for surface concentration of hydrophilic moieties and their change over time, and relates the concentrations to contact angle through Cassie composite wetting model. The model is described by Eq. 1

$$\cos \left( \theta \right) = C_{0} \left( {c_{1} erf\left( {\frac{\delta }{{2\sqrt {Dt} }}} \right) + C_{2} e^{{ - \frac{t}{\tau }}} } \right)\left( {1 - \cos \theta_{\text{u}} } \right) + \cos \theta_{\text{u}} ,$$
(1)

where C0 is the initial surface coverage of the polar groups after plasma treatment (equal to 1 for superhydrophilic surface), \(\delta\) is depth of plasma treatment into the polymer, D is the diffusion coefficient of LMWs, t is the time, \(\tau\) is the relaxation time of reorientation and \(\theta_{\text{u}}\) is the native contact angle of polymer. The term \(\left( {\frac{\delta }{{2\sqrt {\pi D} }}} \right)^{2}\) is the characteristic time of the diffusion process and is extracted from the model as a single parameter.

The characteristic time scales for both diffusion and re-orientations can be extracted from the model when the input is a time series of contact angles. The diffusion and re-orientation characteristic times contribute to the overall rate of recovery. The diffusion characteristic times computed from our CA data at different storage temperatures suggest that recovery to the same degree requires 1.55 days, 97 days and 3400 days, respectively, for samples kept at RT, − 15 °C and − 80 °C. The reorientation relaxation times are short-lived compared to diffusion times and not consequential for long-term hydrophilicity. For the first two computed diffusion characteristic times, respectively, occurring at room temperature and − 15 °C storage, data in our measurement range show a good agreement against the obtained parameters. The diffusion relaxation time for samples at − 80 °C storage cannot be empirically verified, as our experiments only lasted 100 days. However, qualitatively, it matches the expected large delays in recovery at − 80 °C.

Overall, the result is clear that the colder the storage temperature, the slower the hydrophobic recovery. This general temperature-dependent behavior is in accordance with the previously reported Arrhenius interpretations of PDMS hydrophobic recovery (Bauer et al. 2010).

3.2 Attenuated total reflection Fourier transformed infrared spectroscopy

Time-series results of ATR-FTIR measurements on flat PDMS samples showing the chemical composition of the PDMS surface during 10 weeks after the plasma treatment are presented in Fig. 2a. The evolution of the OH vibration peak (3000–3700 cm−1) intensities for each of the three temperatures is shown in the Fig. 2b, showing less change over time for the colder temperatures. Figure 2c shows the intensity of the OH peak as a function of recovery time and temperature. It is clear that three distinct trajectories emerge corresponding to the storage temperatures. The OH signal for room-temperature-stored samples drops to 60% in 24 h and continues a gradual decrease, with a 30% intensity in the end of measurement period. For samples stored at − 15 °C, a drop to around 70% is recorded within 24 h, following a steady decrease to final relative intensity of 37% by the day 72. The intensity for samples kept at − 80 °C drop to 80% in 24 h and stay relatively constant afterwards with the final value of 55%.

Fig. 2
figure 2

a Full spectra measured for a set of samples kept at RT and highlighted region of interest for analysis. Inset graph depicts exclusively the frequency band of OH associated vibrations of samples during recovery period versus pristine PDMS, b normalized OH vibration band (3000–3700 cm−1) shift during 4 weeks for three sets of storage conditions, c normalized OH band max plotted as function of time for three storage temperatures. Error bars indicate the standard deviation of three measurements per data point

3.3 Capillary filling rate

The capillary filling rate of laminar flow in channels with constant cross sections obeys the Washburn relation, which can be written in the form given by Eq. 2 (Washburn 1921)

$$L^{2} = R t = \frac{C \gamma \cos (\theta )}{\mu } t,$$
(2)

where L is the distance filled (location of the filling front), t is the time, γ is the surface tension, θ is the advancing contact angle, μ is the dynamic viscosity and C is a factor that is dependent on the cross-sectional geometry. The parameter R has units of mm2 s−1 and can be considered to be the capillary filling rate. First, we calculated the Reynolds number Re = ρvlμ−1, where ρ is the density, l is the characteristic dimension of channel and v is the meniscus velocity during the fastest possible flow (freshly hydrophilized samples, first 10 mm of the filling). The maximum Reynolds number in the experiments was 0.455 which means that the flow is laminar and well within the Washburn regime.

Figure 3a presents evolution of R and corresponding calculated cos(θ) of a microchannel (width 100 µm, height 51 µm) over time as function of the storage temperature. Figure 3b depicts the schematics of the capillary filling channel. Freshly hydrophilized channels had a capillary filling rate of 83 mm2 s−1 (maximum linear velocity of 68 mms−1). It is noticeable that the trends of filling rate for samples kept at three different temperatures exhibit three distinct trajectories, with samples kept at − 80° and RT showing least and most reduction of filling rate over time, respectively.

Fig. 3
figure 3

Hydrophobic recovery of capillary filling microchannels. a Cosine of calculated dynamic advancing CA and corresponding Washburn constant pertaining to microchannel during recovery period, for three sets of samples stored at three different temperatures. b Schematics of the used meandering microchannel, with inlet and outlet at either ends of the long channel

The results show that the colder the storage temperature, the better the initial capillary filling rate is preserved. Over the 12 days, the RT-stored samples had slowed down to 10 mm2 s−1, while the filling rate of the − 15 °C sample slowed down to 48 mm2 s−1 and the filling rate of the − 80 °C sample slowed only slightly to 73 mm2 s−1 from the initial 84 mm2 s−1.

For a quantitative comparison to the results obtained from planar sheets (Fig. 1), we calculated the dynamic advancing contact angles from the capillary filling rates via Eq. 2 which, exhibit a similar trend of branching out to three trajectories (Fig. 3). Since the same liquid and the same cross-sectional geometry were utilized in all capillary experiments, the only parameter that changed over time and between experiments was the contact angle. Hence, from Eq. 2, we see that the capillary filling rate is directly proportional to the cosine of the advancing contact angle (Eq. 3):

$$R_{\text{t}} /R_{0} \, = \,{ \cos }\left( {\theta_{\text{t}} } \right) / {\text{cos}}\left( {\theta_{0} } \right),$$
(3)

where R0 is the filling rate immediately after plasma treatment, Rt is the filling rate at a specific timepoint, θ0 is the advancing contact angle immediately after plasma treatment and θt is the calculated dynamic advancing contact angle at a specific timepoint. From the goniometer measurements of the planar sheets, the initial advancing contact angle was measured to be 7°, which is used as the value θ0 also in the case of the microchannels. A summary of how cos(θ) ratios at various storage temperatures have evolved over time is represented in Fig. 4. Comparing the calculated microchannel advancing contact angles to the directly measured planar surface advancing contact angles reveals overall a close quantitative agreement between both types of measurements. For example, contact angle data point in the day 2 after the plasma treatment is around 41° and 47° for flat and channel samples, respectively, for − 15 °C storage conditions. Similarly, for samples kept at − 80 °C at day 12, contact angles of 33° and 35° have been recorded from direct measurements and calculations, respectively. It can be seen that the CAs calculated based on the filling rate are systematically slightly higher than those of the goniometer measurements, which when taken into cosine values exhibit a lower value with respect to planar surface values (Fig. 4). A possible explanation is dynamic CA being different at higher liquid velocities (Siebold et al. 2000).

Fig. 4
figure 4

Hydrophobic recovery measured on planar sheets compared to hydrophobic recovery calculated from microchannel filling rates. The cos(θt) tends to decrease as a function of recovery time, more so the higher the temperatures

3.4 Capillary flow pinning on geometrical features

Re-entrant geometrical changes alongside the channel can act as metastable pinning sites for meniscus due to the increased area and the resulting added surface free energy of the expanding liquid–vapor interface. Such an energy barrier can manifest as a threshold pressure and is described by Eq. 4. The energy barrier for a 2D meniscus model has been studied by Man et al. (1998). The increased liquid–gas surface energy of a widening channel causes a pressure barrier given by Eq. 4.

$$P = - \frac{{dU_{T} }}{{dV_{l} }} = \gamma_{la} \left( {{ \cos }_{C} \frac{{dA_{sl} }}{{dV_{l} }} - \frac{{dA_{la} }}{{dV_{l} }} } \right).$$
(4)

Re-entrant structures are common in microfluidic channels even when not specifically designed. They occur with channel intersections and changes in the cross-sectional shape. In addition to these, surface roughness of the microchannel can act as potential pinning sites. For reliable capillary filling, it is, therefore, important that the liquid is able to bypass geometrical pinning sites. In fact it is known that capillary stop valves are unreliable at lower contact angles (Duffy et al. 1999).

The advancement of the meniscus through a geometrical valve requires firstly a pivoting of curvature at the wedge point, followed by establishing an equilibrium contact angle with the slanted wall. Expansion of Eq. 4 at this point for the system predicates the meniscus curvature to fall within the interval of \(\pi / 2- \theta_{\text{c}} \, \ge \,\alpha \, \ge \,\pi / 2- \theta_{\text{c}} {-}\beta\) (Fig. 5a–c). Therefore, depending on the \(\beta\), the curvature α could render a negative value, preventing further movement. A zero or positive value of \(\alpha\) would be minimum requirement of bypassing which in this cases leads to \(\beta \, = \,\pi / 2\,{-}\,\theta_{\text{c}}\). This means P = 0 (flat meniscus) in Eq. 4, from which follows:

Fig. 5
figure 5

Capillary flow pinning on geometrical features. a Positive curvature of the meniscus during advancement, b pivoting and change of the curvature at the wedge, c attaining equilibrium contact angle by meniscus after wedge and further expansion. d A snapshot of capillary flow that is able to bypass all five consecutive geometrical valves with increasing wedge angle. The experiment shown is with advancing contact angle 7° right after hydrophilization

$$\frac{{dA_{la} }}{{dA_{sl} }} = \cos \theta_{c} = \sin \left( {\pi /2 \,{-}\,\theta_{c} } \right) = \sin \beta .$$
(5)

It was our hypothesis that the hydrophobic recovery of a PDMS microchannel would not only cause a slowdown of the filling rate, but also diminish the ability of the flow to bypass pinning sites. Our empirical data on the ability of capillary flow to bypass five different geometrical valves (increasing β) measured at selected days during recovery, as a function of storage temperature, are shown in Table 1. The RT-stored samples eventually lost their ability to bypass the 80° valve at day 7, which corresponds to advancing contact angle 68° (from Fig. 1). Samples stored at − 15 °C and − 80 °C maintained their ability to bypass all the test valves for the entire 12 days span of experiment. A snapshot of a flow that is able to bypass all obstacles is shown in Fig. 5d.

Table 1 Ability of capillary flow to bypass a geometrical valve

Comparing experimental data to the condition given by Eq. 4, it is noticeable that the flow is able to bypass geometrical obstacles better than predicted by Eq. 4. This deviation can be explained by an unaccounted for precursor flow in the model, which is observed in our experiments (Fig. 5d) and also by the 2D nature of the model presented by Leu and Chang (2004) developed a 3D model and showed that the pressure drop for 3D meniscus (in valves up to β = 50o) is much less than what the 2D model would predict.

3.5 Discussion

Different experiments (contact angle, capillary fill rate, capillary valve bypass and IR spectroscopy) in this work together clearly show that the hydrophilicity of plasma-oxidized PDMS can be retained over long periods of time if the recovery process is retarded by storage in a cold temperature. Direct measurements on flat sheets of PDMS over 100 days for samples stored at various temperatures single out the effect of thermally activated processes responsible for the dynamic CAs recovery, while other variables remain constant. PDMS samples stored at − 80 °C were nearly completely wetting after 100 days and based on the trend they would likely have remained hydrophilic for much longer than that. From diffusion and reorientation model, it is predicted that the same degree of recovery happens in 1.55, 97 and 3400 days for samples stored at RT, − 15 °C and − 80 °C, respectively. We can confirm the 1.55 and 97 days predictions from the RT and − 15 °C data empirically as it is within the measurement span. Also from fitted trend lines in Fig. 1, an initial decrease in cos values is observed which occurs during a distinct relaxation time (depending on the storage temperature). Afterwards, there is a plateau stabilization for each temperature which suggests that the recovery has reached an equilibrium in one of its fastest main constituent processes, and further recovery may have shifted to other slower mechanisms. In filling experiments where the measurements capture the capillary flow kinetics, capillary filling rate was only slightly lowered from 83 mm2 s−1 to 73 mm2 s−1 when stored at − 80 °C. The underlying slowdown of meniscus filling over many days in different chips is in par with the thermal dependence of recovery and also in line with final remnant of hydrophilicity of flat sheet PDMS experiments (90% remaining for − 80 °C storage, 60% for − 15 °C and around 20% of original hydrophilicity for RT-stored samples). Meanwhle, it is noticed that the recovery rate of the microchannels seems to be relatively faster than the flat sheets. This observation may be explained by the fact that bulk source of diffusing oligomers is much more available per surface area in the case of 4-walled PDMS channels compared to the single PDMS sheet. Vibrational spectroscopy analysis used in the study traces the presence of the OH– bonds, a direct contributor to the surface hydrophilicity. Radicals containing OH– within the polymer chains created during plasma treatment remain relatively stable and unreacted when reaction energy barrier is unfulfilled (López-García 2019). We ascribe the reduced recovery rate in the cold temperatures predominantly to the reduced rate of thermally active diffusion and reorientation of the LMW species to and from surface, which are known to play a key role in surface recovery and restructuring (Hillborg and Gedde 1998; Kim et al. 2006). This is supported by the ATR-FTIR results showing more hydroxyl and carboxyl groups remaining at or near the surface over time when the samples were stored at colder temperatures. Duration of the data collection was realized based on enough time to capture the nature of the temperature dependence and plateau saturation which has been observed in other experiments.

4 Conclusion

The introduced cold storage method of PDMS material and microchips is shown to perform a near complete preservation of hydrophilicity if cold enough storage temperatures, e.g. − 80° C and lower are used. In terms of simplicity and effectiveness, cold storage compares favorably to other known strategies for postponing the hydrophobic recovery of PDMS. The method also leaves no known physical and chemical footprint regarding the properties of PDMS, and does not require any additional step of post- or pre-plasma modifications. The method is very easily adaptable since storage at − 15° should be available at all laboratories. Cold storage could be an especially attractive method to retain capillary filling properties of microfluidic chips for applications such as passive lab on chip and point of care diagnostics that have preloaded biological ingredients (Hitzbleck et al. 2011), which would be preserved simultaneously in the freezer.