Abstract
This study evaluated the use of an optical inspection system (OIS) to determine the freshness of mackerel (Scomber japonicus). The correlations between the light reflection intensity (LRI) of mackerel eyes (determined using an OIS) and the volatile basic nitrogen content (VBN) and K-value were analyzed. After unloading at the harbor, the mackerel were stored at 4 °C for 9 days and the VBN, K-value, and LRI were determined at 3-day intervals. During storage, the LRI, VBN, and K-value all increased. Furthermore, the LRI was correlated with the K-value and VBN. Therefore, although the LRI cannot be applied as an absolute standard for evaluating freshness, the LRI using an OIS is a suitable nondestructive method for evaluating freshness for quality and risk management in the processing industry when handling large numbers of fish.
Similar content being viewed by others
Introduction
Freshness of fish is the most important aspect because it affects taste, texture and safety. Therefore, the priority value in purchasing fish is freshness. (Huang et al., 2011). However, consumers often cannot obtain objective information about the freshness, quality, and shelf life of mackerel during the sales process, and producers are unable to manage the quality and risk for all of the mackerel handled. Therefore, an improved freshness evaluation method is required to solve this problem and to increase consumer consumption of fish.
The quality and freshness of fish can be measured by using the levels of trimethylamine (TMA), volatile basic nitrogen (VBN), and thiobarbituric acid reactive substances (TBARS), and the K-value (Chang et al., 1998; Kuda et al., 2002). These measurement methods have been evaluated many times (Cheng et al., 2015). However, it takes considerable time to analyze the freshness and quality of fish during distribution, especially examining every fish because fish tissue is required for analysis.
Nondestructive inspection methods have occasionally been used to monitor and evaluate food quality (Daugaard et al., 2010; Huang et al., 2013; Paluchowski et al., 2016; Uddin et al., 2006), but there are no reports using optical inspection methods to measure the freshness of fish, especially the light reflection intensity (LRI) of eyes.
In this study, we used changes in the transparency of the eyes to measure freshness. Eye transparency and physicochemical analyses were conducted on mackerel stored at 4 °C. Then, the correlations between the LRI and physicochemical results were evaluated to assess whether they were appropriate for measuring freshness.
Materials and methods
Sample preparation
Mackerel (Scomber japonicus) were purchased from a wholesale fishery market (Busan, Korea) just after being unloaded from a fishing boat. The mackerel samples were tagged with a numbered label on their tailfin and stored in a refrigerator at 4 °C.
Optical inspection
The optical inspection system (OIS)
The OIS system consisted of an optical camera (Basler Ace A2000-50gc color CCD; Basler, Ahrensburg, Germany), lens (EDMUND 8.5 mm/F1.3, C-Mount; Edmund, Barrington, NJ, USA), and light source (white LED 20 W with a dome fixture; LFINE, Incheon, Korea). Images of the eyes were captured at 50 frames/s by a Gigabit Ethernet with Lab-view I-MAQ-dx Library (VDM; National Instruments, Austin, TX, USA), and the red–green–blue color (RGB) format intensity of each eye was processed in a 64-bit industrial PC environment.
Measurement of the eye reflection intensity
The LRI was measured with the OIS. The mackerel were put on a conveyer and passed through the optical system (Fig. 1A). As each mackerel moved under the optical camera and 11,700 lx light source, its whole body was captured by the optical camera (2000 μs exposure) and in order to uniformly illuminate the mackerel, the light reflector was used to induce dispersion of light. A program automatically selected the eye region (Fig. 1B) in mackerel picture using optical camera. Then, the RGB value of the eye image was measured according to the RGB color classification. In the analysis, only the red value was used because it had the closest relationship to the changes in freshness. The analyzed values were saved as the LRI after calculating the average and deviation.
Chemical analysis
VBN
The VBN content was determined by the Conway method following the guidelines of the Ministry of Food and Drug Safety (MFDS, 2016). Briefly, a 10 g mackerel sample and 50 mL of deionized distilled water (DDW) were put in a glass beaker and homogenized with a homogenizer (AM-7; Nihon Seiki Kaisha, Tokyo, Japan). The homogenate was stirred gently in a shaker for 10 min. After shaking, the homogenate was allowed to stabilize for 5 min at room temperature (RT). This process was repeated three times. The homogenate was centrifuged at 2000×g for 10 min and the supernatant was filtered through Whatman No. 4 filter paper. The pH of the filtrate was adjusted to 4.0 by adding 5% H2SO4 and the volume was made up to 100 mL with DDW. Then, 1.0 mL of 0.01 N H2SO4 was put in the inner space of the Conway unit and 1.0 mL of saturated K2CO3 and the sample were added to the outer space of the Conway unit. The Conway unit was sealed immediately and incubated at 25 °C, with 30% humidity, for 1 h. After incubation, one drop of Brunswik reagent (0.2 g of methyl red and 0.1 g of methylene blue in 300 mL of ethyl alcohol) was added to the inner space of the Conway unit. The solution was titrated using 0.01 N NaOH and the VBN content was calculated using the following equation:
where A is the volume (mL) of 0.01 N NaOH used for sample titration, B is the volume (mL) of 0.01 N NaOH used for blank titration, F is the factor of 0.01 N NaOH, W is the sample weight (g), and D is the dilution factor.
K-value
First, a 10.0 g mackerel sample was homogenated with 30 mL of chilled 10% perchloric acid in a glass beaker and allowed to stabilize for 30 min at RT. The homogenate was centrifuged at 2000×g for 20 min and the supernatant was collected. The precipitate was resuspended in chilled 10% perchloric acid and centrifuged under the same conditions. The supernatants from two extractions were pooled and filtered with Whatman No. 4 filter paper. The filtrate was neutralized with chilled 5 M KOH to pH 6.5 and the final volume adjusted to 100 mL using DDW. Then, the resulting solution was filtered through a 0.45 μm membrane (Cat. no. 4408; PALL Corp., Ann Arbor, MI, USA), and 10.0 μL of the filtrate were injected into a high-performance liquid chromatography (HPLC) instrument (1100 Series; Agilent Technologies, Palo Alto, CA, USA) to analyze nucleic acid-related compounds [NARCs; adenosine triphosphate (ATP), adenosine diphosphate (ADP), adenosine monophosphate (AMP), inosine monophosphate (IMP), inosine, (HxR), and hypoxanthine (Hx)]. The chemical reagents used as NARC standards were purchased from Sigma Aldrich (St. Louis, MO, USA).
The analytical conditions for HPLC were as follows: ultraviolet (UV) detection at 254 nm, the range of absorbed dose (absorbance units full scale; AUF) was 0.5, µBondapak C18 column (3.9 mm i.d. × 300 mm; Waters, Milford, MA, USA), column chamber temperature 40 °C, flow rate 2.0 mL/min, and mobile phase 1% tri-ethylamine (pH 6.5) adjusted with 10% H3PO4. The K-value was calculated using the following equation:
Statistical analysis
Values are presented as mean ± standard deviation (SD). The data were analyzed with SPSS ver. 18.0 (SPSS Inc., Chicago, IL, USA) using a one-way analysis of variance followed by Duncan’s multiple range test. Furthermore, Pearson correlation analysis was used to assess the correlation of freshness between the LRI and chemical analysis results (VBN, K-value). P-values < 0.05 were considered to indicate statistical significance.
Results and discussion
Evaluation of freshness with chemical analyses
When the mackerel were stored at 4 °C, the VBN content increased rapidly during storage from 6.11 mg/100 g at day 0 to 21.26 mg/100 g after 9 days (Fig. 2A). Generally, VBN content is 5–10 mg/100 g when the fresh fish, in the moderately fresh 15–25 mg/100 g; when the fish started to spoil, it increased to 30–40 mg/100 g, exceeding 50 mg/100 g when it was spoiled (Tsai et al., 2018).
The K-value is an important index of fish freshness based on nucleotide degradation. During autolysis in fish, ATP gradually breaks down into ADP, AMP, IMP, HxR, and Hx as a result of enzymatic and microbial activity (Lowe et al., 1993). As degradation progresses, the HxR and Hx contents increase markedly (Hamada-Sato et al., 2005). When determining freshness using the K-value, fresh fish should have a value < 10%, sashimi 10–20%, moderately fresh 20–50%, raw material for processing 35–60%, and spoiled material > 60% (Huang et al., 2015). The K-value of mackerel stored at 4 °C increased rapidly during storage (Fig. 2B), from 4.21% initially to 51.71% (about 12.28 times) after 9 days.
Changes in LRI
During storage at 4 °C, the LRI of mackerel increased with the length of storage (Fig. 2C), from 26.04 at day 0 to 37.5 (1.4 times), 40.62 (1.5 times), and 44.55 (1.7 times) at days 3, 6, and 9, respectively. Initially, the mackerel eyes were transparent and the LRI was low. During storage, the LRI increased gradually. It is thought that the light-reflecting intensity of the fish eyes was inhibited by the change in turbidity of the eye lens. The LRI was highly correlated with the K-value (r = 0.906) and VBN content (r = 0.911) (Table 1). However, it was impossible to estimate the K-value or VBN content in reverse based on the LRI only. Consequently, it is clear that the LRI is of limited value for evaluating freshness. Nevertheless, the LRI can be used to identify the freshness of fish to manage potential risks, and it has the advantage of being a nondestructive method that can potentially be applied when processing large numbers of mackerel.
References
Chang KLB, Chang J, Shiau CY, Pan BS. Biochemical, microbiological, and sensory changes of sea bass (Lateolabrax japonicus) under partial freezing and refrigerated storage. J. Agric. Food Chem. 46: 682-686 (1998)
Cheng JH, Sun DW, Pu H, Zhu Z. Development of hyperspectral imaging coupled with chemometric analysis to monitor K value for evaluation of chemical spoilage in fish fillets. Food Chem. 185: 245-253 (2015)
Daugaard SB, Adler-Nissen J, Carstensen JM. New vision technology for multidimensional quality monitoring of continuous frying of meat. Food Control 21: 626-632 (2010)
Hamada-Sato N, Usui K, Kobayashi T, Imada C, Watanabe E. Quality assurance of raw fish based on HACCP concept. Food Control 16: 301-307 (2005)
Huang H, Liu L, Ngadi MO, Gariépy C. Prediction of pork marbling scores using pattern analysis techniques. Food Control 31: 224-229 (2013)
Huang X, Lv R, Yao L, Guan C, Han F, Yeye E. Non-destructive evaluation of total volatile basic nitrogen (TVB-N) and K-values in fish using colorimetric sensor array. Anal. Methods 7: 1615-1621 (2015)
Huang X, Xin J, Zhao J. A novel technique for rapid evaluation of fish freshness using colorimetric sensor array. J. Food Eng. 105: 632-637 (2011)
Kuda T, Matsumoto C, Yano T. Changes in acid and alkaline phosphatase activities during the spoilage of raw muscle from horse mackerel Trachurus japonicus and gurnard Lepidotriga microptera. Food Chem. 76: 443-447 (2002)
Lowe T, Ryder J, Carragher J, Wells R. Flesh quality in snapper, Pagrus auratus, affected by capture stress. J. Food Sci. 58: 770-773 (1993)
MFDS (Ministry of Food and Drug Safety). Test methods in the Food Code. Seoul, Korea. pp. 221-222 (2016)
Paluchowski LA, Misimi E, Grimsmo L, Randeberg LL. Towards automated sorting of Atlantic cod (Gadus morhua) roe, milt, and liver–Spectral characterization and classification using visible and near-infrared hyperspectral imaging. Food Control 62: 337-345 (2016)
Tsai CL, Shiau CY, Sung WC. Effects of blanching and refrigerated storage on quality attributes of hybrid abalone (Haliotidae discushannai X H. diversicolor diversicolor). J. Food Process. Pres. 42: e13608 (2018)
Uddin M, Okazaki E, Ahmad MU, Fukuda Y, Tanaka M. NIR spectroscopy: A non-destructive fast technique to verify heat treatment of fish-meat gel. Food Control 17: 660-664 (2006)
Acknowledgements
This research was part of a project titled “Technological development of an intelligent quality evaluation system for marine products (20150583)”, funded by the Ministry of Oceans and Fisheries, Korea.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Choi, JW., Jang, MK., Hong, CW. et al. Novel application of an optical inspection system to determine the freshness of Scomber japonicus (mackerel) stored at a low temperature. Food Sci Biotechnol 29, 103–107 (2020). https://doi.org/10.1007/s10068-019-00639-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10068-019-00639-z