Introduction

Local hydrology in the Ozarks ecoregion of Missouri (USA) is dominated by karst features and processes such as losing streams, caves, and large spring flow systems. In Missouri, over 4,400 springs have been documented, including eight first-magnitude springs (Jackson 2013) that have an average discharge equal to or exceeding 100 ft3 s−1 (2.8 m3 s−1; Meinzer 1927). Recharge via losing streams is the common recharge mode for spring systems in the Ozarks and several of these systems have been well characterized by dye-tracing studies (Vandike 1992, 1996; Lerch et al. 2005; Mugel et al. 2009; Miller and Lerch 2011). Additionally, while distributary springs represent an important type of discharge feature observed within the Ozarks, typified by Montauk and Toronto Springs (Beckman and Hinchey 1944; Vineyard and Feder 1982), there are a limited number of studies documenting distributary and multiple outlet spring systems in karst settings (Quinlan and Ewers 1985; Quinlan 1990; Goldscheider 2005). Typically identified through dye-tracing work or contaminant transport investigations, distributary spring systems can have a variety of forms that may vary depending on hydrologic conditions, recharge area characteristics, and local hydrogeology (Quinlan and Ewers 1985; Quinlan 1990; J. Vandike, Water Resources Center-Missouri Department of Natural Resources, personal communication, 2014). Results of these studies show that multiple springs in such systems may receive positive traces from single tracer injections or may show similar levels of a particular contaminant. Quinlan and Ewers (1985) reported that distributary spring systems were a common feature in carbonate aquifers, and they described such systems as having four principal origins: (1) enlargement of pre-existing anastomoses due to large head differences between flooded passages and base level; (2) collapse and blockage of a spring orifice forcing alternate routes to develop; (3) diversion to lower routes as base level is lowered; and (4) backflooding from surface streams that forces undersaturated water into anastomoses at the potentiometric surface. However, the existing literature has few studies that quantitatively document distributary spring systems and their hydrogeological features, and there are no existing studies describing their geochemistry or documenting possible mixing of recharge sources within these systems. For the purposes of this report, the term distributary springs will be used to describe spring systems that have the following characteristics: (1) multiple springs in close geographic proximity to one another; (2) springs having shared recharge areas (whether in total or a portion of); and (3) flow through a shared conduit system.

Wet Glaize Creek (WG) is located in the central Missouri Ozarks in southeastern Camden County (Fig. 1). The 332 km2 watershed is underlain by Ordovician age sandstones and dolomites and the majority of the streams in the watershed have significant losing reaches (Harvey et al. 1983). Toronto Springs is a distributary spring system, located in the northern portion of the watershed, which consists of numerous perennial spring outlets located along the north and south sides/banks of WG (Figs. 2 and 3). Carroll Cave (CC) is a stream cave with 32 km of known passages, located 4 km to the south of Toronto Springs, which provides a significant percentage of the flow discharging from Toronto Springs (Fig. 4) (Miller 2010). Dye tracing has positively traced CC to eight of the springs, and WG to ten springs (Fig. 3). Seepage runs—measuring loss of stream flow between upstream and downstream gaging stations (Lerner et al. 1990)—in streams of the WG watershed have also identified two major losing reaches along the WG main channel, downstream from dye injection locations shown to lose to Toronto Springs (Miller 2010). These results revealed that complex recharge relationships exist at Toronto Springs, and prompted the additional studies reported here. There are a number of different approaches that have been employed to obtain information on sources and other properties of recharge (Scanlon et al. 2002) and can be subdivided into physical (Lerner et al. 1990; Rushton 1997), tracing (e.g., Leaney and Allison1986; Ronan et al. 1998; Arnold and Allen 1996; Flint et al. 2002) and numerical methods (Singh 1995; Hatton 1998; Qian et al. 2006). Mixing models typically using two to six geochemical end member tracers (Christopherson and Hooper 1992; Doctor et al. 2006; Barthold et al. 2011) have been successfully used to determine sources of recharge (e.g., Liu et al. 2004, 2008a, b, 2013) that compare favorably to results using isotope analysis (Liu et al. 2004; Doctor et al. 2006).

Fig. 1
figure 1

Location of the State of Missouri (United States of America) and the Wet Glaize Creek watershed

Fig. 2
figure 2

Map of Wet Glaize Creek watershed, showing karst features, Carroll Cave, and known structural features. Labelled creeks include: Creek A = Traw Hollow, Creek B = Davis Hollow, Creek C = Barnett Hollow, Creek D = Mill Creek, Creek E = Wet Glaize Creek, Creek F = Sellars Creek, Creek G = Conns Creek. Spring, sinkhole, and structural feature data from Missouri Department of Natural Resources, Missouri Geological Survey (2007, 2010a, b)

Fig. 3
figure 3

Map of Toronto Springs. The color of each spring symbol indicates the positive dye traces made to that spring from end-members Carroll Cave (CC) and Wet Glaize Creek (WG)

Fig. 4
figure 4

Map of surveyed passages in Carroll Cave. The major flow direction of each stream is shown as a blue arrow. The map represents roughly 32 km (20 miles) of mapped passages. Cave survey data (R. N. Lerch, Carroll Cave Conservancy, personal communication, 2014)

The specific objectives of this research were to: (1) characterize the individual geochemistry of 11 springs within the Toronto Springs system and the two recharge sources through high-resolution monitoring of specific conductivity (SpC), temperature, and pH; (2) analyze major ion concentrations in the springs to develop end-member mixing models to estimate the proportion of CC and WG to the recharge of each spring; and (3) synthesize results of the mixing models and previously conducted dye tracing and seepage run studies to develop a conceptual model that describes the primary flow paths of the Toronto Springs system.

Materials and methodology

Setting

The WG drainage basin is located in the central Missouri Ozarks region and is within the Grandglaize Basin, which, in turn, is part of the Osage River Basin. The area is characterized by rolling hills dissected by meandering streams and local elevation varies from 213 to 348 m above sea level with total vertical relief of about 135 m. Land cover is dominated by grasslands and deciduous forests, which account for 91 % of the total land cover in the watershed (Missouri Resource Assessment Partnership 2005). The region is dominated by karst topography, with features that include springs, caves, and sinkholes (Fig. 2), and the majority of local surface drainages have losing stream reaches (Harvey et al. 1983). The underlying bedrock is Ordovician dolomites and sandstones, with the cave and karst areas mainly occurring within the Gasconade Dolomite. Overlying the Gasconade Dolomite is the Roubidoux Formation; a grouping of sandstone and chert with some dolomite interbeds, which is found primarily along the ridgetops, and the Jefferson City-Cotter Dolomite is exposed in a few areas near the Montreal Fault Block (Middendorf 1984), the major structural feature of the study area. Additional structural features include the Mill Creek Fault, the Mill Creek Syncline; and in the study area, the dip is generally 1° to the east (Helwig 1965). While many of the faults are minor in overall displacement, they play an important role in the loss of surface water to the subsurface environment.

Carroll Cave (Fig. 4) is a large stream cave system which has been mapped to a length of 32 km, though exploration and survey is still ongoing. The dendritic pattern and curvilinear passages are indicative of floodwater recharge from losing streams predominantly along bedding partings (Palmer 1991). The cave contains three streams that flow independently from one another, creating two in-cave drainage divides. The numerous side passages contribute flow as tributaries to these larger streams. Thunder River, the largest stream, flows through the cave for over 11 km, dropping 60 m in elevation, before reaching the water table at a large terminal lake room. Qualitative dye tracing has shown the surface recharge areas for Thunder River to be Traw Hollow (located to the south of the cave), Davis Hollow, and portions of south Barnett Hollow. Confusion Creek, the second largest stream, was discovered in 2009 and is reached via a large side passage within the cave known as DL7. Recharge to Confusion Creek is from a series of large sinkholes located to the west of the main cave system. Carroll River, the smallest of the three streams in terms of discharge, has been truncated by the downcutting of Thunder River and appears to currently receive recharge only from epikarstic aquifers located above and adjacent to the cave system (Miller 2010).

Toronto Springs (Fig. 3) is located in the northern portion of the WG drainage basin. The spring system consists of approximately 20 perennial and ephemeral springs which discharge from the alluvium of the WG floodplain. Two of the springs emerge from openings at the base of dolomite outcrops, with one known to be a cave (spring TS8). Eleven of the perennial springs were selected for monitoring, which had substantial flow and deep enough channels to accommodate deployment of dataloggers, seven of which were located on the south side of WG and four on the north side. Total average flow for the spring system is approximately 800 L s−1 with a flow range of 10–90 L s−1 for each spring (Miller 2010).

Methodology

Spring-water monitoring

Up to three YSI Sonde 6600 dataloggers (YSI, Yellow Springs, OH) were deployed for continuous, high-resolution monitoring of the 13 sites (11 springs, WG, and Thunder River in CC; Figs. 2 and 3). One site was chosen as a reference site (TS7) at which the YSI datalogger was continuously deployed while the other dataloggers were rotated among sites at 2–4-week intervals. Data were collected for pH, SpC (μs/cm), and temperature (°C) at 15-min intervals. Dataloggers were deployed from May 2009 through September 2010. The data were then examined for baseflow periods and statistical analyses (see ‘Methodology’, ‘Statistical analysis’) were used to determine if individual springs were significantly different from one another in these basic water quality parameters. Only baseflow conditions were examined as inundation of the springs by WG during high flow periods invalidated comparisons among the springs under high flow conditions. Baseflow YSI data were chosen using four criteria:

  1. 1.

    The datalogger sensors had sufficient time to equilibrate to the surrounding spring water.

  2. 2.

    No erratic readings existed or acceptable replacement data were available.

  3. 3.

    SpC, pH, and temperature readings were stable or asymptotically approaching equilibrium following a runoff event.

  4. 4.

    Once baseflow periods were identified, a 3-day interval was randomly chosen for each site.

Each of the selected data sets represented 288 individual data points (3 days × 96 readings per day) for each site. These data were then used to calculate ratios to the reference site at TS7 and for conducting statistical analyses. Each site in the study, where possible, had a datalogger deployed during cool months (October–March) and warm months (April–September) to examine possible seasonal variations. However, due to time and resource constraints, three sites (TS4, TS5, TS6) have two warm periods and no cool periods, and one site (TS2) had no warm season data. Data were downloaded, sensors calibrated, and maintenance performed twice per month.

Chemical analysis

Samples were collected for ion analyses twice per month from February to September 2010 from the 13 sites already described. Grab samples were collected under baseflow and runoff conditions in 500-ml plastic bottles and placed on ice during transport to the laboratory. A total of 167 samples were collected. Major cations, HCO3 , and CO3 2− concentrations were determined within 24 h of collection; anion concentrations were determined within standard holding times (Eaton et al. 2005). Cations were analyzed by flame photometry (Na+ and K+) or by atomic absorption spectrometry (Ca2+and Mg2+) as described by Nathan et al. (2012). Bicarbonate (HCO3 ) and CO3 2− concentrations were determined by titration using H2SO4 along with indicators of phenolphthalein and methyl orange (Eaton et al. 2005). Anion analyses of NO3 , SO4 2−, PO4 3−, Cl, and F were completed using ion chromatography with electrolytic suppression on a Dionex DX 600 system in accordance with methodologies described in Standard Methods for the Examination of Water and Wastewater (Eaton et al. 2005). Anion analyses were conducted for all sites during the first two sampling periods to ensure charge balance occurred (within 10 %), after which one site was randomly chosen for each sampling set. Coincident with the grab samples collected for ion analysis, instantaneous measurements of pH, temperature, and SpC were conducted. Additional details about the chemical analyses can be found in Miller (2010).

Statistical analysis

For the continuous monitoring data, statistical analyses were performed on datasets created by dividing the raw values of an individual spring by the corresponding values at reference site TS7, which was chosen as the reference since the site is a spring branch that integrates the flow from all springs on the south side of WG. Due to resource constraints, it was not possible to monitor all 13 sites simultaneously and, therefore, the computation of ratios to a common reference provided a means of standardizing the data so that site differences could be statistically analyzed. The ratio was computed for each individual spring to that of the reference site using

$$ {R}_{ij}={S}_{ij}/{S}_{\mathrm{TS}7j} $$
(1)

where R ij is the ratio for a value between a given spring and that for TS7, S ij is the i-th spring for parameter j, where j represents a value for pH, temperature, or SpC; STS7j is the value at reference site TS7 for the j-th parameter. The ratio data were not normally distributed according to the Kolmogorov-Smirnov test (p < 0.05 for all parameters); therefore, non-parametric statistical methods were used for determining differences between sites.

Mann–Whitney tests (U-tests) were used to determine if seasonal differences (cool vs. warm) for a site were significantly different (α = 0.05). If significant differences were found between seasonal datasets, then the seasonal data were analyzed separately. Due to the sampling periods, datalogger maintenance, and the time span of the research, some sites (TS2, TS4, TS5 and TS6) did not have both seasons represented. For those sites with two warm season datasets, the U-test was used to determine if the two warm season datasets were significantly different. Then the dataset closest to the mid-point of the season (i.e., the end of June) was chosen. One exception was made in splitting the seasonal datasets for spring TS2. The presumptive warm season data for the site exhibited unseasonably cool water temperature, even though the sampling periods were technically in the warm season. Because of this, it was ultimately decided to include the TS2 data only in the cool season analysis.

The Kruskal-Wallis test (H-test) was used to determine differences among sites using the ratio data for pH, SpC, and temperature (α = 0.05). Pair-wise comparisons were then made to determine significant differences in mean rank between sites based on critical difference values using the method of Chan and Walmsley (1997). The critical difference values are a function of the total number of observations in the data set, the number of comparisons, and the number of observations per site. Therefore, critical differences calculated for the cool season were smaller, compared to the warm season critical difference, due to the fact that fewer overall sites were monitored during the cool season. The major cation (Ca2+, Mg2+, Na+, K+) and HCO3 data were normally distributed based on the Kolmogorov-Smirnov test (α = 0.05). Thus, one-way analysis of variance (ANOVA) was used for determining differences among sites (α = 0.05), and 95 % confidence intervals about the mean concentrations were computed for these data. In addition, cluster analysis by Ward’s method of agglomeration was used to determine groups of springs based on their average Ca2+, Mg2+, and HCO3 concentrations and SpC to support the choice of end members for the mixing models. Ward’s method computes the distance between two groups as proportional to the change in the within group sum of squares that results when two groups are combined (Ward 1963).

Two-end-member mixing model analysis

Previous dye-tracing results (Miller 2010) demonstrated that CC and WG are the dominant recharge sources to Toronto Springs. The two-end-member mixing model developed here assumed that CC and WG were the primary end-members of the monitored springs at Toronto Springs and that other recharge sources were negligible. Two end members provide the minimum number of inputs into such hydrological mixing models (Christopersen and Hooper 1992) and such models have been successfully used to quantify source contributions in a variety of settings (e.g., Gong et al. 1995; Liu et al. 2008a) Thus, a simple two-end-member mixing model (Eq. 2) was developed:

$$ {P_i}_{\mathrm{HM}} = \left({S}_{ij} - {\mathrm{LM}}_j\right)/\left({\mathrm{HM}}_j - {\mathrm{LM}}_j\right) $$
(2)

where P iHM is the proportion of the highest valued end member contributing flow to spring, i; S ij is the i-th spring for parameter j, where j represents the cation or anion concentration, or SpC; HM j is the highest end member value for parameter j, represented by CC; and LM j is the lowest end member value for parameter j, represented by WG. Average site values for Ca2+, Mg2+, and HCO3 concentrations and the instantaneous SpC data were used as the input for the mixing models. In an effort to provide robustness to the input datasets, SpC was included because it is an overall indicator of dissolved ion concentrations in the water samples and provided an independent measurement method from that of the specific ion concentrations. A mixing model representing the average of the proportions from these four parameters was also computed.

Results and discussion

Differences in physical and chemical characteristics among springs

Results of the U-tests for temperature, pH, and SpC values for all sites indicated significant seasonal differences with p-values <0.05. Monitoring data from springs TS1 and TS7 (reference site) showed slight, but significant, differences in temperature and larger differences in SpC and pH by season (Fig. 5). Also, note the observed diurnal fluctuations at the reference site for temperature and pH, while TS1 does not show such a pattern. Other sites showed similar seasonal patterns in all three parameters (data not shown), but temperatures generally showed greater differences between seasons than that of TS1. Because of these differences, the cool and warm season ratio datasets were analyzed separately to assess differences among the sites. Results of the H-tests for the warm and cool season datasets showed significant differences between sites with respect to pH, temperature, and SpC (Table 1). Major differences in temperature were observed between sites with WG having the highest mean rank in the warm season and the lowest mean rank in the cool season, an anticipated result for a surface stream. Conversely, CC had among the highest mean ranks for temperature in the cool season, grouped along with sites TS1 and TS13, indicating a more groundwater dominated flow regime. The datasets for pH showed similar results, with WG having the highest mean rank in both seasons (most basic) and spring TS12 the lowest mean rank in both seasons (most acidic). Specific conductivity showed differences among sites that were consistent with anticipated differences between surface stream and groundwater flow systems. WG had the lowest SpC in the warm season due to seasonally high flow, while spring TS8 and CC had the highest mean ranks. The H-test results clearly demonstrated that the springs had distinct chemical and physical properties. Furthermore, results of dye-tracing studies in an earlier phase of this research showed that springs with shared recharge areas were generally similar (i.e., not significantly different) in these three parameters (Fig. 3; Miller 2010). However, the dye traces only established point-to-point connections and could not be used to estimate the proportion of recharge sources to the springs.

Fig. 5
figure 5

Temperature, specific conductivity (SpC), and pH of Spring TS1 and the reference site, Spring TS7, in warm and cool seasons. a Warm season temperature; b Cool season temperature; c Warm season SpC; d Cool Season SpC; e Warm season pH; f Cool season pH. Vertical lines indicate 3-day period used for statistical analyses

Table 1 Mean ranks and differences among sites for temperature, pH, and specific conductivity (SpC) in cool and warm seasons

Major ion concentrations

Of the major ions, only Ca2+ concentrations showed significant differences between sites, with average concentrations ranging from 0.802 to 1.00 mmol L−1 (Table 2). Spring TS8 and CC had the highest average Ca2+ concentrations, and both were significantly greater than TS2 and WG, while the other springs were intermediate in concentration. Concentrations of Ca2+, Mg2+, and HCO3 showed considerable variation across sites (Table 2 and Fig. 6), but WG and TS2 consistently had the lowest concentrations of all three ions. CC and TS8 also had the highest average Mg2+ concentrations, and the highest or among the highest HCO3 concentrations (Fig. 6). Average Mg2+ and HCO3 concentrations of the remaining springs were generally between those of WG and CC. Figure 5a shows the average Mg2+ versus Ca2+ concentration data by site. Eight sites fell below the 1:1 line, three above the line, and two on the line, demonstrating that, overall, the sites had slightly greater average concentrations of Mg2+ (0.931 mmol L−1) than Ca2+ (0.918 mmol L−1). This indicated that the Gasconade dolomite is, at least locally, slightly enriched in Mg2+ compared to a 1:1 ratio. Concentrations of Na+ and K+ were very similar for all sites (Table 2). Average SpC ranged from 338 μS cm−1 at WG to 396 μS cm−1 at TS8, and there were no significant differences in average SpC between sites (Table 2). Similar to the major ion concentrations, WG and TS2 had the lowest SpC. In contrast, CC had an average SpC (364 μS cm−1) that was intermediate among the sites and similar to several springs that were intermediate in major ion concentrations (TS1, TS4, TS10, TS11, and TS13; Table 3). Overall, WG and CC generally encompassed the range of observed Ca2+, Mg2+, and HCO3 concentrations, but not the range of SpC.

Table 2 Average concentrations of major cations and bicarbonate (HCO3 ) for 11 springs, Carroll Cave (CC), and Wet Glaize Creek (WG)
Fig. 6
figure 6

Average concentrations and 95 % confidence intervals (gray error bars) for 11 springs, Carroll Cave, and Wet Glaize Creek. a Ca2+ and Mg2+ concentrations by site. b HCO3 and Mg2+ concentrations by site. Symbol colors indicate relative concentration groups based on cluster analysis of average Ca2+ (a) or HCO3 (b) concentrations— red = high; orange = intermediate; and yellow = low

Table 3 Site groups based on cluster analysis of average Ca2+, Mg2+, and HCO3 concentrations and specific conductivity (SpC)

Cluster analysis was used to determine major groups among the sites based on their average ion concentrations and SpC. Resulting dendrograms for all four parameters showed three distinct clusters (Fig. 7). For Ca2+ and SpC, a reduction in the number of clusters from >4 to 3 occurs at a distance of <0.5 for both parameters (Fig. 7), and subsequent reduction from three to two clusters occurs at distances that are much greater than that required for previous combinations. In the Ca2+ dendrogram (Fig. 7), for example, this indicated that sites CC, TS8, and TS12 were a distinct cluster (i.e., distance of 4.4 was required for combining) from the eight sites in the adjacent cluster. Similarly for the SpC dendrogram (Fig. 7), the six-site cluster including CC was distinctly different (i.e., distance of 3.3) from the five-site cluster that included WG. Dendrograms for Mg2+ and HCO3 (not shown) were very similar to that of Ca2+ and resulted in similar groups (Table 3). Overall, the results of the cluster analysis indicated the existence of three distinct groups—low, intermediate, and high concentration or conductivity (Table 3 and Fig. 6). However, SpC showed a very different arrangement of sites within each group compared to that of the ion concentrations (Table 3). For SpC, CC was in the intermediate conductivity group and was included with a large group of springs (TS1, TS4, TS10, TS11, and TS13) that were in the intermediate concentration group for the ion data. Further, three sites that were in the intermediate group based on ion concentrations (TS5-7), were included in the low conductivity group along with TS2 and WG. In contrast, groups based on ion concentrations showed that WG and TS2 were always in the low concentration group, and CC and TS8 were always in the high concentration group (Table 3 and Fig. 6). Most of the remaining springs were in the intermediate group. These results were consistent with earlier dye-tracing studies (Miller 2010) demonstrating that CC and WG were the primary recharge sources to the springs. The ion data also supported the choice of CC and WG as end members in the mixing models, and indicated that ion-specific data were more discriminating than SpC for identifying recharge sources to the springs. This research supports the use of major ion concentrations as a valid and simple approach for discriminating recharge sources in distributary spring systems.

Fig. 7
figure 7

Site groups based on the cluster analyses for average Ca 2+ concentration and specific conductivity (SpC)

Two-end-member mixing model

Mixing model results showed that the springs represented a range from groundwater to surface-water-dominated recharge sources. Results of the Ca2+ mixing model showed a range of values from 27 to 107 % of the recharge contributed by CC (Table 4). However, all of the springs except TS2 were estimated to have >50 % contribution from CC, and among the ion-specific models, the Ca2+ model gave the highest estimated proportion of CC to the springs, with an average of 63 % for all sites. The Mg2+ mixing model had the narrowest spread of estimates for end-member contributions compared to the other models with the estimated CC contribution ranging from 4 to 78 % (Table 4). In contrast to the Ca2+ model results, the proportion of recharge from CC estimated by the Mg2+ model was <40 % for seven of the sites, and all sites except TS13 resulted in lower proportions of recharge from CC. The Mg2+ model resulted in the highest estimates of surface-water contribution to the springs with an average of 58 % of the spring recharge attributed to WG. Results of the HCO3 model were generally intermediate to that of the Ca2+ and Mg2+ models. Estimated recharge proportions of CC ranged from −4 to 136 %, but the average overall sites for the HCO3 model showed slightly greater groundwater inputs (55 % CC) than surface water. For eight of the springs (TS1, TS4-7, TS10, TS11, TS13), the HCO3 model estimated the proportion of CC recharge to be in a relatively narrow range (37–50 % CC), and all of these springs, except TS13, were intermediate to that of the Ca2+ and Mg2+ model results.

Table 4 Mixing model estimates of the recharge proportions of Carroll Cave (CC) and Wet Glaize Creek (WG) to each spring

The model for SpC showed very different results in the end-member proportions from the ion-specific models because of the narrow range (340–397 μS cm−1) of the data and the fact that CC was not the high end member. As a result, estimated recharge proportions from the SpC model were inconsistent with the ion-specific models and tended to greatly over-estimate CC recharge contribution compared to them. Overall, the SpC model estimated that 92 % of the recharge was attributed to CC, but comparisons of specific sites showed large differences between results of the ion-specific and SpC models. For several springs (TS4, TS10, TS11, and TS13), the SpC model indicated that CC dominated the recharge to these springs, but the ion-specific models showed more equal contributions of recharge from CC and WG. Further, differences between the results of the SpC and ion-specific models for TS8 and TS12 were much larger. While results of the Ca2+ and Mg2+ models were seemingly inconsistent for TS8, they reflected the similarity in ion concentrations between CC and TS8, demonstrating that the site was dominated by groundwater recharge (see the following discussion). Thus, the mean of the ion-specific models was considered to be the most robust estimate of the recharge proportions, and the SpC data were not included in the mean model. Results of the mean model showed that eight of the springs (TS1, TS4-7, TS10, TS11, TS13) had nearly equal proportions of recharge from CC and WG, one spring (TS2) was dominated by recharge from WG, and two springs (TS8 and TS12) were dominated by recharge from CC. Viewed spatially (Fig. 8), the eight springs with similar recharge proportions, and therefore ion concentrations, were distributed throughout the flood plain and on both sides of the WG channel. Spring TS12, dominated by CC recharge, is located on the north side of the WG channel, yet CC flow is from the south. These observations provided evidence for the existence of separate sub-surface conduits flowing to specific springs or groups of springs (see the following). Moreover, the ion-specific mixing models illustrate that the Toronto Springs system represents an active groundwater/surface-water mixing zone between a karst aquifer and a surface stream channel. This work builds upon recent advances in karst hydrogeology that reveal complexities in recharge–discharge relationships and surface stream-conduit exchange within aquifer systems (Moore et al. 2009; Gulley et al. 2010; Luhman et al. 2012).

Fig. 8
figure 8

Map of Toronto Springs showing the end-member proportions for individual springs based on the overall mixing model

While the ion-specific mixing models were useful for describing recharge source mixing for the majority of the monitored springs, the fact that the model was not applicable for some springs suggested the influence of other recharge sources to these springs. Spring TS8 was one example for which the average Ca2+ and HCO3 concentrations were greater than CC and, thus, resulted in >100 % apparent contribution from groundwater. However, previous groundwater tracing indicated that TS8 was not positively traced from CC, and recharge to this spring apparently represents contribution from a separate karst aquifer, also formed in Gasconade dolomite, which resulted in very similar ion concentrations to that of CC. In addition, WG was not traced to spring TS8, yet the Mg2+ mixing model indicated that 22 % of the recharge was derived from the creek. Given the location and chemical characteristics of TS8, any source of surface recharge was likely from lower Barnett Hollow Creek; however, no dye tracing has been conducted to confirm this connection. Spring TS12 gave a similar result to that of TS8 for the HCO3 model because the spring had slightly greater average HCO3 concentrations than CC. In contrast to TS8 though, TS12 has been traced from CC, and the ion-specific models estimated that CC was the dominant recharge source to this spring. Spring TS2 also had a result inconsistent with the HCO3 mixing model because the site had an average HCO3 concentration slightly lower than that of WG. Analogous to TS12, spring TS2 has been traced from WG, and the mean model estimated the creek to account for 91 % of the recharge to this spring. In contrast, the Ca2+ and Mg2+ mixing model results for TS2 indicated contributions from CC, but the cave was not positively traced to the spring. Apparently, other groundwater sources may provide a small proportion of the recharge to TS2. The mixing model results demonstrate that the ion concentrations of CC and WG are representative of local groundwater and surface streams, respectively, and support the hypothesis that WG and CC are the two primary recharge sources to the Toronto Springs system.

Development of a conceptual model for the Carroll Cave–Toronto Springs system

Distributary spring systems have often been viewed in a simplistic manner in which the various springs were presumed to derive from a common recharge source, resurging through the alluvium at various locations. Results from this study show that this view is incorrect for Toronto Springs, and the individual springs can represent different mixing zones with distinct water chemistry. Results of the mixing models along with previous dye-tracing studies, seepage runs, geological mapping, detailed survey of the CC system, and known structural features of the WG watershed (Helwig 1965; Middendorf 1984; Miller 2010; Fig. 2), support the hypothesis that distinct conduits recharge the springs or groups of springs and that surface and subsurface water interactions occur along these complex flowpaths. Furthermore, it is proposed that springs with common proportions of end-member recharge, even when on opposite sides of the base level stream, were supplied by the same conduit or fracture and these flow paths controlled the contribution of the end-member recharge. This represents a new conceptual model for distributary spring systems in that the water discharging from the 11 springs at Toronto Springs is not geochemically homogenous but is dependent on the complex mixing of groundwater and surface stream-flow systems. Detailed studies of the hydrology and hydrochemistry of distributary spring systems are lacking in the literature and, therefore, no conceptual models exist to describe the physical setting or the nature of recharge source mixing occurring within these systems.

The conceptual model developed here to describe this system includes the major known recharge sources to Carroll Cave via losing streams in Traw and South Barnett hollows (Figs. 9 and 10). These losing streams recharge either Thunder River, a Thunder River tributary (DL7), or Confusion Creek within Carroll Cave, but eventually converge into a single large conduit at the water table that extends for approximately 4 km northeast towards Toronto Springs. The lower portion of this large conduit is viewed as the major mixing zone of WG with CC groundwater (Fig. 9). Structural faults of the Montreal Fault Block and cutoff springs along WG provide the probable conduits that facilitate the mixing of surface and ground waters that subsequently resurge as distinct spring outlets along the north and south sides of WG. Toronto Springs represents a unique distributary spring system created by the unusual combination of a large karst recharge area in close proximity to a major fault block.

Fig. 9
figure 9

Simplified profile of the study area, portraying portions of the conceptual model from Traw Hollow through Thunder River in Carroll Cave to Toronto Springs. Profile is looking to the northwest, left side of the profile is south

Fig. 10
figure 10

Conceptual model of the Carroll Cave–Toronto Springs system, showing recharge sources to Carroll Cave (CC) and the mixing of groundwater and surface-water systems contributing flow to Toronto Springs (TS). Flow direction in the model is indicated alongside each flow line in the model and is generally southwest to northwest. Spring and sinkhole feature data from Missouri Department of Natural Resources, Missouri Geological Survey (2007, 2010a)

Conclusions

Intensive monitoring of 11 springs and their two principal recharge sources demonstrated that the springs were distinctly different in terms of temperature, pH, and SpC, and these differences also varied seasonally among the springs. Mean ion concentrations were not significantly different between sites, except for Ca2+, but cluster analysis of Ca2+, Mg2+, HCO3 , and SpC among sites demonstrated the existence of three distinct groups and supported the use of CC and WG as recharge end members in the mixing models. Results of the mixing models indicated a broad range of end-member proportions for the springs, from surface water to groundwater dominated, and elucidated the complex mixing that can occur within a distributary spring setting. Two springs, TS2 and TS8, provided additional support for the development of the generalized mixing models, showing that CC and WG were representative of local groundwater and stream flow regimes, respectively. Results from multiple lines of evidence combining this and previous work—mixing model results, dye tracing, seepage runs, cave survey, and known structural features of WG watershed—support the hypothesis that distinct conduits supplied flow to the springs or groups of springs, and these conduits controlled the end-member recharge contributions and geochemistry of the springs. This represents a new understanding of the complexities that can exist within distributary spring systems, and a conceptual model of the hydrogeologic setting of this conduit structure has been proposed to synthesize these results. Toronto Springs represents a complex distributary spring system where groundwater from the CC karst aquifer mixes with surface water from the WG stream channel to discharge via distinct conduits within the flood plain of WG. This study provides another methodological tool for examining karst aquifer flow systems and groundwater/surface-water interactions in large drainage basins to aid in better understanding the recharge sources and discharge characteristics of complex distributary spring systems.