Introduction

The health benefits of physical exercise practice are irrefutable, including risk reductions of at least 20–30% for more than 25 chronic medical conditions and premature mortality [1, 2]. Nevertheless, generic physical activity guidelines should not be used when working with clinical populations. Exercise prescription should be individualized based on underlying medical condition and functional status for optimal patient care [3].

Glaucoma is the leading cause of irreversible blindness worldwide [4]. As a result, public health strategies are being discussed to minimize the negative consequences of glaucoma, although the possibility to adopt different public health strategies vary significantly across countries [5]. Remarkably, the reduction and stabilization of intraocular pressure (IOP) are the only strategy that has proven to be beneficial for the prevention and management of glaucoma, with all the possible interventions (i.e., surgery, pharmacological treatment, or lifestyle) aiming to reduce and stabilize IOP levels [6,7,8,9]. In this regard, the effects of a lifestyle factor such as the physical exercise on IOP control have been extensively explored in recent years, with different types of physical exercise showing either a positive (i.e., IOP reduction) or negative (i.e., IOP increase) effect for the prevention and management of glaucoma [10].

Endurance-type exercises (e.g., running or cycling) performed at low to moderate intensities cause an IOP reduction [11, 12], whereas resistance-type exercises (e.g., weightlifting) provoke an acute IOP rise which is accentuated at higher training intensities (i.e., using heavier loads and performing repetitions closer to muscular failure) [13,14,15]. In non-exercise contexts, there is scientific evidence that IOP values are greater in when adopting a horizontal position compared to the seated and upright positions [16,17,18,19,20]. Specifically, Vera and colleagues [21] found that the IOP response to reading at a close distance (30 cm) is dependent on body position, observing greater IOP values in the supine compared to a seated position. Remarkably, a number of resistance training exercises (e.g., bench press) can be performed while adopting different body positions (e.g., standing, sitting, lying down), but the differences in the IOP behavior when the same exercise is performed adopting different positions have never been examined.

In order to address the gaps found in scientific literature, we designed an experimental study to compare the impact of performing ten repetitions of the bench press exercise in supine and seated positions on IOP levels. Complementarily, these possible differences were determined for three exercise intensities, namely a control condition (no physical effort), medium-intensity condition (half of the 10-repetition maximum (RM) load), and high-intensity condition (10-RM load). Based on the accumulated scientific evidence in non-physical activities [16,17,18,19,20,21], we hypothesized greater IOP values when executing the bench press in a supine compared to a seated position. We also hypothesized that the IOP values will be higher for the more physically demanding exercise conditions [13, 14] and there will be a cumulative and progressive IOP rise as a function of accumulated physical effort [22].

Methods

Participants

An a priori sample size calculation was performed using the GPower 3.1 software. This software has been widely used in research studies and supports sample size and power calculation for various statistical methods (F, t, χ2, z, and exact tests) [23, 24]. For this analysis, we assumed an effect size of 0.20, alpha of 0.05, and power of 0.90, which projected a necessary sample size of 23 participants. At this point, 23 physically active individuals (10 men and 13 women) were recruited to participate in this study (age = 24.7 ± 4.8 years, body mass = 71.2 ± 12.4 kg and body height = 1.73 ± 0.09 m; data presented as mean ± SD). All participants were of Caucasian ethnicity and non-smokers. They were free of any systemic or ocular disease, were not taking any medication, and had no family history of glaucoma. The study followed the guidelines of the World Medical Association (Declaration of Helsinki) and was approved by the Institutional Review Board. Written informed consent was obtained from all participants before the initiation of the study.

Intraocular pressure assessment

A rebound tonometer (Icare IC200, TiolatOy, INC. Helsinki, Finland) was used to measure IOP from the right eye. This new model has shown an acceptable level of reproducibility in the sitting and supine positions and a high agreement with Goldman applanation tonometry [25, 26]. The IC200 tonometer permits to accurately measure IOP when the subject is sitting, standing, or lying in a supine position due to its free angle measurement addition, and incorporates a light signal to minimize position-related errors. Also, this handheld tonometer has several advantages in practical terms (e.g., easy and rapid measurement, well-tolerated procedure, and does not require topical anesthesia or fluorescein), which makes this device a highly valuable tool for measuring IOP in applied settings. Following the manufacturer recommendation, IOP measurements were taken with the probe placed at a distance of 5 to 8 mm from the central cornea while the subject fixated on a distant target. IOP measurement was conducted by the same examiner (PL).

Testing procedures

The first session was used to determine in a randomized order the 10-RM load (i.e., the load with which participants can perform a maximum of 10 repetitions) during the bench press exercise performed in both supine and seated positions. The session began with a warm-up consisting of jogging and upper-body dynamic stretching exercises. Subsequently, participants performed the first set against the 50% of their self-perceived 10-RM load. Participants were told to stop the set after 5 repetitions when they or an experienced strength and conditioning researcher identified that more than 10 repetitions could be performed. The load was then incremented in agreement between the participant and the researcher and a new set was performed after 3 min of passive rest. Participants needed between 3 and 6 sets to reach their 10-RM load. The 10-RM load was 39.04 ± 18.05 kg in the supine position and 53.57 ± 21.31 kg in the seated position.

The second session allowed us to test our hypotheses and consisted of 6 sets of the bench press exercise (2 positions (supine and seated) and 3 exercise intensities (control, medium intensity, and high intensity)). The 10-RM load and the 50% of the 10-RM load were used for the high- and medium-intensity conditions, respectively. In the control condition, participants simulated the same movement without using any additional load. The order of the sets was randomized and they were separated by 10 min of passive rest. Participants were asked to adopt the corresponding body position, and the baseline measurement was taken after maintaining this position for 60 s. During the exercise set, IOP was assessed immediately after performing each repetition (a total of 10 measurements) in a relaxed position (elbows fully extended). Lastly, IOP was measured after 10 s of passive rest (recovery measurement).

The supine bench press was performed with an Olympic free-weight barbell and weight disks (Fig. 1 panel A). The seated bench press was performed using a functional electromechanical dynamometer (FEMD) (Fig. 1 panel B) [27]. This FEMD (Dynasystem, Model Research, Granada, Spain) allows to perform a wide variety of movements and it can deliver a wide variety of stimuli (i.e., isokinetic, isotonic, elastic, isometric, inertial, eccentric, and vibration). The control core of this device permits to precisely regulate both force and angular velocity through a 2000-W electric motor. The user applies forces on a rope that winds on a roller, thus controlling and measuring both force and linear velocity. A load cell detects the tension applied to the rope and the resulting signal goes to an analog-to-digital converter with 12-bit resolution. Displacement and speed data are collected with a 2500-ppr encoder attached to the roller. Data from the different sensors are obtained at a frequency of 1 kHz [28].

Fig. 1
figure 1

Photographs of the data collection. Panels A and B show the supine and seated bench press conditions, respectively

Experimental design

A cross-over study was designed to examine the influence of the body position adopted during upper-body dynamic resistance training on IOP values. The 10-RM loads during the bench press exercise performed in supine and seated positions were determined in the first testing session. In the second session, participants randomly performed 6 exercise sets (3 exercise intensities (control, medium intensity, and high intensity) × 2 body positions (supine and seated)) and the IOP was measured before exercise, after each of the 10 repetitions, and after 10 s of recovery (12 IOP measurements for each experimental condition). The six exercise sets were performed in a randomized order in order to minimize the possible effects of fatigue on the findings of the present study, and environmental conditions were kept constant during the course of the experiment (∼ 22 °C and ∼ 60% humidity).

Statistical analyses

Firstly, the normal distribution of the data (Shapiro–Wilk test) and the homogeneity of variances (Levene’s test) were checked. Also, a two-way repeated measures ANOVA (2 × 3: body position (supine and seated) and exercise intensity (control, medium intensity, and high intensity)) was performed to assess if baseline IOP measurements were comparable.

For the main analysis, we performed a repeated measures ANOVA for IOP (2 × 3 × 12), considering the body position (supine and seated), exercise intensity (control, medium intensity, and high intensity), and point of measure (baseline, repetitions 1–10, and recovery (a total of 12 measurements)) as within-participant factors. Multiple comparisons were performed, and they were corrected with the Holm–Bonferroni procedure. The magnitude of the changes was reported as Cohen’s d effect size (d) and partial eta squared (ηp2) for T and F tests, respectively. An alpha value of 0.05 was considered as statistically significant. The JASP statistics package (version 0.16.2) was used for statistical analyses.

Results

The normal distribution of the data and the homogeneity of variances were confirmed (all p-values > 0.05). The analysis of baseline IOP values showed statistically significant differences for the main factor “body position” (F1,22 = 47.85, p < 0.001, ηp2 = 0.69), with greater values in the supine than in the seated position. However, no differences were reached for the main factor “exercise intensity” or the interaction “body position × exercise intensity” (F2,44 = 2.67, p = 0.081; F2,44 = 1.38, p = 0.262; respectively).

The analysis of IOP showed statistically significant differences for the main effects of “body position” (F1,22 = 107.50, p < 0.001, ηp2 = 0.83), “exercise intensity” (F2,44 = 85.29, p < 0.001, ηp2 = 0.80), and “point of measure” (F2,44 = 38.34, p < 0.001, ηp2 = 0.64). Also, there were statistically significant differences for the interactions “body position × exercise intensity” (F2,44 = 29.44, p < 0.001, ηp2 = 0.57), “body position × point of measure” (F11,242 = 8.45, p = 0.004, ηp2 = 0.11), “exercise intensity × point of measure” (F22,484 = 13.48, < 0.001, ηp2 = 0.38), and “body position × exercise intensity × point of measure” (F22,484 = 2.34, < 0.001, ηp2 = 0.10) (Fig. 2). Post hoc analyses revealed greater IOP values in the high-intensity condition in comparison to the medium-intensity and control conditions (corrected p-value < 0.001, Cohen’s d = 1.17; and corrected p-value < 0.001, Cohen’s d = 2.72, respectively), as well as for the medium-intensity condition when compared to the control condition (corrected p-value < 0.001, Cohen’s d = 1.54). Complementarily, we calculated the IOP change associated with exercise performance in supine and seated positions (Fig. 3).

Fig. 2
figure 2

Intraocular pressure behavior in supine (panel A) and seated (panel B) positions for the control, medium-intensity, and high-intensity conditions. Error bars show the standard error

Fig. 3
figure 3

Changes in intraocular pressure levels between the medium- and high-intensity conditions with respect to the control condition during the bench press performed in supine and seated positions. Error bars show the standard error of the difference

Discussion

This study was designed to examine the influence of the body position adopted during the execution of the bench press exercise on IOP. Our data revealed a mediating effect of the body position on IOP behavior, obtaining greater IOP increments when the bench press was performed in the supine compared to the seated position. Additionally, and in agreement with previous studies, (i) IOP increased progressively over the course of the set [22], (ii) IOP increments were positively associated with exercise intensity [13, 14], and (iii) IOP returned to baseline values immediately after the cessation of the effort [29, 30]. Based on the current results, performing the dynamic bench press to or near to muscular failure, and especially while adopting a supine position, should be discouraged in individuals who need to minimize IOP increments. These findings may have important applications for exercise prescription in glaucoma patients or those at risk.

This is the first study that has explored during virtually the same exercise, bilateral upper-body push, the effect of the body position adopted during the execution of the exercise on IOP levels. Our preliminary hypothesis was confirmed because the supine bench press exercise caused greater IOP increments than the seated bench press exercise. As displayed in Fig. 2, the IOP peaks in the supine and seated positions were of approximately 26 and 20 mmHg, respectively, which evidence the possible clinical relevance of these differences. To our knowledge, this is the first investigation assessing the impact of the body position adopted during resistance training on IOP, although these results agree with previous studies using non-physical activities [16,17,18,19,20,21]. In line with previous studies [19,20,21], the baseline IOP differences between the seated and supine positions ranged from 1 to 3 mmHg. However, during the execution of the bench press exercise, the IOP differences between the supine and seated positions are greater during the physical effort in comparison to baseline conditions (average difference during 10 repetitions of ~ 5.5 mmHg vs. ~ 3 mmHg in baseline conditions). Based on the present outcomes, it is reasonable to prioritize the adoption of standing/seated positions instead of lying down for the execution of the bench press exercise when maintaining stable IOP levels is desired or necessary [31, 32].

Our data corroborate previous findings about the factors mediating the IOP response to resistance training. First, the execution of highly demanding physical effort is known to provoke an acute and transient IOP rise, which these changes being positively associated with the accumulated level of effort [22, 33]. In the current study, there was a linear IOP rise during exercise performance in the medium- and high-intensity conditions and while adopting both the seated and supine positions (coefficients of correlation (Pearson’s r) ranging from 0.75 to 0.93). Second, greater intensities (i.e., loads lifted) in resistance training are linked to more abrupt IOP increments [13,14,15, 22, 34,35,36,37], which is also observed in the present study. Lastly, these IOP effects have demonstrated to be transient, namely, IOP values return to baseline levels after a few seconds of exercise cessation [14, 29, 30, 33]. Here, we found that 10 s of passive recovery were enough to reach baseline IOP levels. This set of results supports that those studies designed to capture IOP changes as a function of exercise with a post-exercise measurement may underestimate the impact of exercise on IOP levels.

The physiological mechanisms responsible for the mediating effects of body position on the IOP response to resistance training cannot be ruled out from this investigation; however, there are several plausible explanations to these findings. The execution of highly demanding resistance training is accompanied by the Valsalva maneuver, which permits to enhance trunk stability [38]. Nevertheless, the hemodynamic changes linked to the Valsalva maneuver are also dependent on the body position adopted, with these differences being attributed to differences in intrathoracic blood volume and venous return [39]. In addition, the adoption of recumbent positions has been associated with an increased episcleral venous pressure and ocular tissues congestion, including the choroid (i.e., the most vascularized ocular tissue) [16, 18, 40]. All these factors may have contributed to the differences in the IOP response to dynamic resistance training in the seated and supine positions.

Limitations and future research

The findings of this study reveal that performing 10 repetitions of the bench press exercise leading to muscular failure caused greater IOP rises when performed in supine compared to seated position. Nevertheless, there are different factors that may limit the validity of these results, and they must be listed. First, several factors such as individuals’ fitness level [34, 41,42,43], type of exercise [30, 36], or participants’ sex [14, 44] have demonstrated to influence the IOP response to exercise, and thus, the results of this study should be interpreted with caution in this regard. Second, the experimental sample was formed by healthy young adults, and the physical capacity and physiological responsiveness to exercise in other populations (e.g., elderly subjects with chronic conditions) may be different [45]. Third, ocular hemodynamics in glaucoma patients after postural change is known to be altered [46], which support that further studies are needed to determine the IOP responsiveness to resistance training while adopting different body positions in glaucoma patients. Lastly, this work is limited to the acute effects of resistance training on IOP, and future studies should be designed to determine the long-term effects of exercise practice on glaucoma prevention and management.

Conclusions

The differences in IOP values between the supine and seated positions are accentuated during effort. There was a progressive IOP rise in both body positions, exercise intensity was positively associated with the magnitude of the IOP increment, and IOP returned to baseline levels immediately after exercise cessation. This set of findings support previous evidence on the IOP response to highly demanding resistance training, and incorporate novel insights into the mediating role of the body position adopted during the execution of resistance training exercises on IOP levels. Our results suggest that the adoption of a seated/standing position (instead of a supine/prone position) should be prioritized for maintaining more stable IOP levels, and may help to the management and prevention of glaucoma. The external validity of these results for glaucoma patients needs to be tested in future studies.