Abstract
The Japanese organ transplant law was revised in July 2010 in order to enable children aged <15 years to donate organs. However, the waiting time for orthotopic heart transplantation (HTx) is as long as 636 days in children due to a shortage of organ donors. Ventricular assist devices (VADs) have been widely used as a bridge to transplantation in Western countries, whereas experience with VADs is limited in Japan due to a lack of device availability for small children. This study aimed to clarify the clinical profiles and outcomes of children with advanced heart failure in Japan and to investigate the importance of mechanical circulatory support (MCS), VADs, and extracorporeal membrane oxygenation (ECMO) in children. A retrospective chart review of patients with advanced heart failure who were eligible for HTx between January 2006 and May 2015 was performed at the Department of Pediatric Cardiology, Tokyo Woman’s Medical University, Japan. Patients were divided into two groups based on need for MCS. Clinical data pre- and post-revision of the Japanese organ transplant law were compared. Preoperative clinical conditions were evaluated based on Interagency Registry for Mechanically Circulatory Support (INTERMACS) profiles. Twenty-two patients were included in the study, 12 of whom required MCS. VADs were implanted in nine patients and ECMO was needed in seven patients. Of the MCS group, 5 deaths occurred in patients with a preoperative INTERMACS profile-1. High total bilirubin was found to be associated with mortality by multivariate logistic regression analysis (OR 7.8, p = 0.02). Wait list mortality was 32 % and no difference in clinical profiles pre- and post-revision of the Japanese organ transplant law was observed. Approximately 55 % of pediatric patients with advanced heart failure required MCS support. Preoperative conditions such as INTERMACS profile-1 and high total bilirubin were associated with poor outcomes. The Japanese organ transplant law revision had no significant influence on patient profiles or outcomes.
Similar content being viewed by others
References
Teuteberg JJ, Stewart GC, Jessup M, Kormos RL, Sun B, Frazier OH, Naftel DC, Stevenson LW (2013) Implant strategies changes over time and impact outcomes. JACC Heart Fail 1:369–378
Patel CB, Cowger JA, Zuckermann A (2014) A contemporary review of mechanical circulatory support. J Heart Lung Transplant 33:667–674
Kirklin JK, Naftel DC (2008) Mechanical circulatory support: registering a therapy in evolution. Circ Heart Fail 11:200–205
Almond CS, Morales DL, Blackstone EH, Turrentine MW, Imamura M, Massicotte MP, Jordan LC, Devaney EJ, Ravishankar C, Kanter KR, Holman W, Kroslowitz R, Tjossem C, Thuita L, Cohen GA, Buchholz H, St Louis JD, Nguyen K, Niebler RA, Walters HL 3rd, Reemtsen B, Wearden PD, Reinhartz O, Guleserian KJ, Mitchell MB, Bleiweis MS, Canter CE, Humpl T (2013) Berlin Heart EXCOR pediatric ventricular assist device for bridge to heart transplantation in US children. Circulation 127:1702–1711
Fraser CD Jr, Jaquiss RD, Rosenthal DN, Humpl T, Canter CE, Blackstone EH, Naftel DC, Ichord RN, Bomgaars L, Tweddell JS, Massicotte MP, Turrentine MW, Cohen GA, Devaney EJ, Pearce FB, Carberry KE, Kroslowitz R, Almond CS; Berlin Heart Study Investigators (2012) Prospective trial of a pediatric ventricular assist device. N Engl J Med 367:532–541
Gournay V, Hauet Q (2014) Mechanical circulatory support for infants and small children. Arch Cardiovasc Dis 107:398–405
Miera O, Schmitt KR, Delmo-Walter E, Ovroutski S, Hetzer R, Berger F (2014) Pump size of Berlin Heart EXCOR pediatric device influences clinical outcome in children. J Heart Lung Transplant 33:816–821
Morales DL, Almond CS, Jaquiss RD, Rosenthal DN, Naftel DC, Massicotte MP, Humpl T, Turrentine MW, Tweddell JS, Cohen GA, Kroslowitz R, Devaney EJ, Canter CE, Fynn-Thompson F, Reinhartz O, Imamura M, Ghanayem NS, Buchholz H, Furness S, Mazor R, Gandhi SK, Fraser CD Jr (2011) Bridging children of all sizes to cardiac transplantation: the initial multicenter North American experience with the Berlin Heart EXCOR ventricular assist device. J Heart Lung Transplant 30(1):1–8
Kihara S, Kawai A, Endo M, Koyanagi H, Kurosawa H (2002) Extracorporeal membrane oxygenation and left ventricular assist device: a case of double mechanical bridge. Heart Vessels 16:164–166
Barge-Caballero E, Segovia-Cubero J, Almenar-Bonet L, Gonzalez-Vilchez F, Villa-Arranz A, Delgado-Jimenez J, Lage-Galle E, Perez-Villa F, Lambert-Rodríguez JL, Manito-Lorite N, Arizon-Del Prado JM, Brossa-Loidi V, Pascual-Figal D, Fuente-Galan Lde L, Sanz-Julve M, Muñiz-Garcia J, Crespo-Leiro M (2013) Preoperative INTERMACS profiles determine postoperative outcomes in critically ill patients undergoing emergency heart transplantation: analysis of the Spanish National Heart Transplant Registry. Circ Heart Fail 6(4):763–772
Stein ML, Robbins R, Sabati AA, Reinhartz O, Chin C, Liu E, Bernstein D, Roth S, Wright G, Reitz B, Rosenthal D (2010) Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS)-defined morbidity and mortality associated with pediatric ventricular assist device support at a single US center: the Stanford experience. Circ Heart Fail 3(6):682–688
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors have no conflict of interest to declare.
Rights and permissions
About this article
Cite this article
Shimizu, M., Nishinaka, T., Inai, K. et al. Outcomes in children with advanced heart failure in Japan: importance of mechanical circulatory support. Heart Vessels 31, 1162–1167 (2016). https://doi.org/10.1007/s00380-015-0722-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00380-015-0722-9