1 Introduction

Electrical characterization techniques of bulk semiconductors using conventional methods are very often inconvenient as electrical contacts are needed. For industrial applications, on-line inspections are required. In this context, non-contact, non-destructive and fast methods for the measurement of thermal and electrical properties of semiconductors seem to be more appropriate. Photothermal radiometry (PTR) is a non-contact method which enables to measure optical and thermal parameters of materials [1, 2]. In the case of semiconductors, PTR additionally yields information about the recombination parameters [3, 4]. Recently, it was found that for infrared (IR) semitransparent semiconductors, it is possible to obtain information on the carrier concentration with quantitative values after calibration to Hall carrier concentration [5]. In this paper, a simple normalization procedure of the PTR spectra, which allows to determine the carrier concentration in CdSe single crystals using the normalized effective IR absorption coefficient measured by means of the PTR method and the theory proposed by Ruda [6], is presented.

2 Materials preparations and experimental methods

2.1 Materials

n-type CdSe single crystals were grown by the high-pressure Bridgman method without a seed under an argon overpressure. The crystals were cut perpendicular to the growth direction into 0.9- to 1.3-mm-thick plates. Next, the plates were mechanically polished and chemically etched in a mixture of K2Cr2O7, H2SO3 and H2O in the proportion 3:2:1. Then, they were treated in CS2 and hot 50 % NaOH solution and finally rinsed in water and ethyl alcohol.

2.2 Experimental setups

The PTR experimental setup is presented in Fig. 1. The thermal waves were excited using an argon ion laser (LASER) with an output power of 200 mW and a photon energy of 2.41 eV (the operating wavelength λ = 514 nm). The laser beam of about 2 mm diameter was intensity modulated by means of an acousto-optical modulator (A-O M) in the frequency range 1 Hz–100 kHz and focused onto the sample. Two BaF2 lenses (L1, L2) were used to collect IR radiation from the sample (S) on the photoconductive mercury cadmium telluride (MCT, HgCdTe) detector with a detectivity peak at 10.6 µm. The IR transmittance of the BaF2 lens was about 90 %. The MCT detector covering the IR range from 2 to 12 µm was supplied with a ZnSe cutoff filter (F) in the front having a transmittance of about 90% in the wavelength range of the detector. The signal (amplitude A and phase φ) of the MCT detector was amplified and filtered by a lock-in amplifier (LIA, Stanford 830 DSP) and analyzed by a personal computer (PC). The IR spectra were measured using the IRScope II, attached to a IFS 66 IR spectrometer (Bruker GmbH, Ettlingen, Germany) equipped with the liquid N2 cooled mercury cadmium telluride (MCT) detector. The detailed description of the IR spectrometer and an experimental procedure were presented elsewhere [7]. The IR absorption coefficients were calculated from the transmission spectra under the assumption that the optical reflection coefficient is constant in the investigated spectral range.

Fig. 1
figure 1

PTR experimental setup

3 Theoretical model

In the Drude theory, the free carrier absorption is proportional to the carrier concentration N and can be written as follows [8]

$$ \beta \left( \lambda \right) = \frac{{e^{2} \cdot N \cdot \lambda^{2} }}{{4 \cdot \pi^{2} \cdot m_{\text{e}} \cdot \varepsilon_{0} \cdot c^{3} \cdot n_{r} \cdot \tau }}, $$
(1)

where e is the elementary charge, m e is the effective mass of an electron, ε 0 is the electric permittivity, c is the speed of light and τ is the relaxation time of the scattering processes. For semiconductors, however, the dependence of the optical absorption coefficient on the wavelength of the absorbed radiation is rather of the type of β(λ) ~ λ p, where 2 < p ≤3.5. The parameter p depends on the scattering mechanisms. There are three main types of scattering mechanisms: acoustic phonons, optical phonons and impurity scattering mechanisms. Using the quantum mechanical approach, it is possible to calculate the free carrier absorption coefficient. The IR absorption coefficient can be written as a sum of all scattering mechanisms as follows [9]

$$ \beta \left( \lambda \right) = A_{\text{acoustic}} \times \;\lambda^{1.5} + A_{\text{optical}} \cdot \lambda^{2.5} + A_{\text{impurity}} \cdot \lambda^{3.5} , $$
(2)

where A acoustic, A optical, A impurity are proportionality coefficients for particular scattering mechanisms.

For semiconductors with the carrier concentration N, in the range of 1014–1017 cm−3, Ruda [6] found the following relationship between the IR absorption coefficient measured at λ = 10 μm, the p coefficient and the carrier concentration for n-ZnSe:

$$ N = 6. 7 \cdot 10^{ 1 5} \cdot \left( { 3. 5 - p} \right) \cdot \beta \left( \lambda \right),\quad \lambda = 10 \mu {\text{m}}. $$
(3)

4 Experimental results and discussion

According to the validity range of the Ruda formula, the method presented should be applicable for the carrier concentration in the range 1014–1017 cm−3. Two samples that possess a concentration within almost this range were available for this study. Figure 2 presents the IR absorption coefficients for CdSe crystals. As one can observe with an increasing excitation wavelength, the IR absorption coefficient increases monotonically. This behavior is typical for an absorption caused by free carriers. In Fig. 1, the experimental data are displayed together with a fit using the relation:

Fig. 2
figure 2

IR absorption spectra as a function of wavelength λ for CdSe crystals with the best fits using formula (4) (lines) to the experimental data. For clarity, the experimental points were reduced

$$ \log \left( {\beta \left( \lambda \right)} \right) = a + p \cdot \log \left( \lambda \right) $$
(4)

The obtained fitting parameters p for a-CdSe and b-CdSe are 2.43 and 2.30, respectively. The absolute error in determination of the p parameter is Δp = 0.02 and 0.03, respectively. This means that the dominating scattering mechanism in these crystals is the phonons scattering mechanism. Assuming that the formula (3) can be applied to the n-CdSe crystals, the carrier concentration can be estimated. The carrier concentrations for a-CdSe and b-CdSe crystals calculated with the formula (3) are 1.38 × 1017 and 3.54 × 1016 cm−3, respectively.

The effective IR absorption coefficient and the thermal diffusivity of CdSe crystals were estimated using the one-dimensional heat transport model for IR semitransparent crystals [5]. The experimental procedure consists in measuring the PTR signal in the transmission and reflection configurations with the PTR signal obtained in reflection configuration used as the reference signal. The applied theoretical approach is valid only for semiconductors with very short recombination lifetime (with a direct energy bandgap). For semiconductors with an indirect energy bandgap, such as silicon, the influence of plasma waves has to be taken into account. In paper [5], authors found the very good agreement between the experimental values of the thermal diffusivity obtained using the PTR method and the photopyroelectric technique [10]. The good agreement of the data obtained by the two different techniques proved the reliability of the PTR data and of the theoretical approach based on the adjustment of the two parameters, i.e., the thermal diffusivity D t and the effective IR optical absorption coefficient β IR,eff. The obtained results of the effective IR absorption coefficient for a-CdSe and b-CdSe crystals were 7.5 ± 0.2 and 0.9 ± 0.1 cm−1, respectively.

The effective IR absorption coefficient β IR,eff represents the IR absorption coefficient averaged over the wavelength range of the MCT detector, in this case, in the wavelength between 2 and 12 μm. When the IR absorption coefficient increases monotonically along with the increasing excitation wavelength in the detection wavelength range, one can normalize the effective absorption coefficient to the IR absorption coefficient measured at λ = 10.6 μm. Figure 3 presents a proposed normalization procedure.

Fig. 3
figure 3

Relation between the effective IR absorption coefficient and the IR absorption coefficient measured at λ = 10.6 μm using the IR spectrometer

Figure 3 shows that the relation between the effective IR absorption coefficient and the IR absorption coefficient measured at λ = 10.6 μm using the IR spectrometer for the samples investigated can be linear in the first approximation. The slope coefficient is 2.6 ± 0.2. A limitation of this procedure is worth to be discussed here. In the case of semiconductors with the carrier concentration higher than 2 × 1017 cm−3, this procedure failed. For example, for Cd1−xMgxSe crystals, the free carrier absorption region moves toward smaller wavelengths of about 6 μm [7]. Multiplying the values of the effective IR absorption coefficient of CdSe crystals and the slope coefficient, one can calculate the normalized effective absorption coefficient β n,IR,eff. Assuming that the Ruda formula can be rewritten (3) as follows

$$ N = 6.7 \cdot 10^{15} \cdot \left( {3.5 - p} \right) \cdot \; \cdot \beta_{\text{n,IR,eff}} , $$
(5)

the carrier concentration in CdSe crystals can be calculated. Table 1 presents the values of the carrier concentration obtained using Hall measurements, the IR spectroscopy and the PTR method.

Table 1 Carrier concentration in CdSe crystals measured using the Hall measurements, IR spectroscopy (IR) and PTR method

As one can see in Table 1, the carrier concentrations obtained using the three techniques for a-CdSe are in very good agreement. However, for b-CdSe, the value obtained from the PTR experiment does not match with the other values within the experimental uncertainty. The estimated errors shown in Table 1 were obtained using the exact differential method taking into account errors in determination of the normalization slope, p coefficients and effective IR absorption coefficients. Compared to the Hall method, the results obtained are in reasonable agreement. Although the Hall method usually has smaller errors (1–2 %), the error strongly depends on the sample preparation procedure (contacts) [11]. The PTR method presented in this paper does not suffer from the sample preparation procedure.

5 Conclusions

A simple normalization procedure of the IR spectra is proposed which allows to determine the carrier concentration in CdSe crystals using the effective IR absorption coefficient deduced from PTR experiments has been presented in this paper. The results obtained are in reasonable agreement with the results obtained from the Hall measurement and the IR spectroscopy. The proposed method can be used for IR semitransparent semiconductors and with the carrier concentration in the range between 1014 and 1017 cm−3.