1 Introduction

Laser brazing offers the ability to join different materials with good visual quality. The joint is achieved by the wetting of a preheated substrate material with a molten brazing material. Conventional laser brazing processes use large spot sizes of several millimetres to realise the process, based on a single Fresnel absorption of the laser beam [1]. Frequently used brazing materials are aluminium and copper. These materials are highly reflective, leading to a low absorption of the laser beam and low process efficiencies [2].

A concept derived from laser welding offers the opportunity to increase the absorption, whereby decreasing the laser spot leads to an intensity that is high enough for the local evaporation of the metal (threshold intensity). A vapour capillary called a keyhole is formed, in which the laser beam is absorbed multiple times, thereby increasing the efficiency [3]. The energy input into the material is done localised in the keyhole and distributed by heat conduction and convection [4]. The high absorption of the laser beam and the localised energy input result in a high temperature gradient in the vicinity of the keyhole [5]. The laser power needed for the evaporation of the metal decreases with decreasing spot size. The keyhole process has been successfully transferred to the brazing process in preliminary investigations [6]. The preheating of the substrate, which is favourable for the process by increasing the wetting time [7], is realised by heat conduction from the overheated molten brazing material when the molten brazing material wets the substrate surface.

The keyhole depth is multiple times higher than its opening diameter. In laser welding, this characteristic is used to increase the welding depth [8]. In laser brazing processes, the melt pool depth, and therefore the keyhole depth, is limited by the substrate material. Combining the high aspect ratio of the keyhole shape with the round shape of the wire (brazing material) results in a welding through in the middle of the brazing material and an incomplete melting of the edges (cf. Fig. 1, middle). Heat conduction results in a wider melt pool as the keyhole width, but the widening is not sufficient for a complete melting of the wire without melting of the substrate when using small spot sizes as in this investigation. By oscillating the laser beam using a beam scanning system, the intensity can be distributed over a wider area without increasing the laser power [9]. This decreases the melt pool depth, increases the melt pool width and facilitates an efficient laser brazing process with a complete melting of the brazing material yet without melting the substrate material [6].

Fig. 1
figure 1

Effects of the keyhole formation on the melt pool depth and temperature gradients in the melting of wire-shaped material. The brazing material is not completely melted in the pictures to point out the influence of the process strategies onto the melt pool shape

In laser brazing processes, the temperature field at the interface between the brazing and substrate materials is important for the joint quality. Homogenous and stationary temperature fields are regarded as the ideal process state [10]. Especially, when using brazing and substrate materials with only slight differences between the melting temperatures, these properties are essential to prevent molten areas in the substrate material. Figure 1 shows the expected temperature profiles in the brazing material wire for different spot sizes and in comparison, to the linear oscillation of the keyhole. The temperature distribution of a large spot is expected to be more homogeneous than that of the others. For the considered process, it is important to understand the influence of using the deep penetration effect in combination with beam oscillation onto the temperature field in the interface referring to the homogeneity.

The temperature profile on top of the seam is regarded as a suitable indicator of the temperature field in the interface [11]. An often used possibility to measure the temperature field in dynamic processes is infrared thermography [12]. In welding processes, it can be used, e.g. for an online adaption of the weld parameters [13] or to identify and locate welding defects [14]. The main advantages of the process are the contactless, time-resolved and geometry-independently measurements [15]. Therefore, it is an effective method for real-time monitoring of objects and processes without disturbing [12]. This method is based on the detection of an object’s emitted thermal radiation, which is conditional on the emissivity, which itself is dependent on the temperature, the surface condition and the physical state [11]. Conventional infrared pyrometer measures in a spectral range of 780 nm to 1 mm [16] and a temperature range from 20 to 1700 °C [12]. The emissivity of the detected object is a challenging factor in infrared thermography. The influence can be reduced by using, e.g. a ratio pyrometer (two-colour pyrometer) which is mostly independent of the emissivity [16]. For measurements in the constant liquid phase, the assumption of a constant emissivity is generally feasible. However, this is not the case for solid materials [17]. Another challenge is the influence of the ambient temperature which can only be neglected for high differences between the measured and the ambient temperature [16].

Further investigations into the laser brazing process with keyhole formation have shown that the oscillation parameters influence the maximum temperature as well as the occurrence of molten areas in the substrate by varying the average beam velocity [18]. In addition, investigations with respect to different oscillation patterns have demonstrated an influence on the local intensity distribution [19]. Linear oscillations have turning points that result in varying beam velocities across the movement, thus causing varying intensities and temperatures in the melt pool. These varying temperatures can cause local overheating in the turning points (cf. Fig. 1) which can lead to molten areas in the substrate material. Circular oscillation patterns, which have constant beam velocities (if neglecting the influence of the feed rate) and thus constant intensities, are probably more suitable for the formation of homogenous temperature fields in the melt pool. The oscillation frequency also affects the temperature distribution by changing the number as well as the time interval of the laser passes. Higher frequencies result in multiple local laser passes, which can increase the homogeneity of the temperature field. Therefore, the influence of different oscillation patterns and different oscillation frequencies on the local temperature distribution on top of the weld pool shall be investigated in this study. The resulting temperature fields are evaluated regarding to their homogeneity.

2 Experimental

The experiments were carried out using a single-mode fibre laser (IPG YLR-1000-SM) and a two-dimensional laser scanning system (Scanlab WelDYNA). The focal diameter was 34 μm. The brazing material was an AlSi12 aluminium alloy wire with a diameter of 1.2 mm, and the substrate material was zinc-coated steel (DC 01 ZE 25/25, dimensions 150 mm × 35 mm) with a thickness of 1.0 mm. The melting temperature of AlSi12 is 580 °C e[1], and the melting temperature of DC 01 is 1452 °C [20]. The experiments are carried out as bead-on-plate brazing tests (brazing material application on a flat substrate) as illustrated in Fig. 2. The focal position perpendicular to the substrate surface was set in the middle of the wire. The wire angle was 45°. The shielding gas argon covered the process zone with a flow rate of 7.0 l/min. Table 1 shows the experimental conditions and the adjusted brazing parameters. Three different oscillation patterns were applied with different characteristics. The circular movement had a constant beam velocity whereas the line and eight-shaped movement had turning points which resulted in varying velocities across the movement.

Fig. 2
figure 2

Microsection of a bead-on-plate brazing seam brazed with superimposed linear beam oscillation

Table 1 Experimental conditions and brazing parameters (varied parameters are marked in bold)

The temperature measurements were carried out with a line pyrometer (DIAS Pyroline HS 512N) with a maximum measurement frequency of 2048 Hz. The pyrometer measures in a temperature range of 650 to 1500 °C with a 512-pixel line sensor. The applied optic had an angle of aperture of 9° × 0.04°. The position of the measurement line was transversal to the brazing direction with an angle of 45°. The distance between the seam and the pyrometer was 500 mm. The measuring frequency was set to the maximum frequency of 2048 Hz. Figure 3 shows the setup for the temperature measurements. For each parameter set, three samples were analysed. The emissivity of the measurements was set to a value of 0.3, which is the emissivity for molten aluminium at 800 °C [21]. This was possible because the pyrometer only detected those molten areas in which the emissivity could be regarded as constant [17].

Fig. 3
figure 3

Setup for the temperature measurements

The temperature measurements TM,i were evaluated using the Pyrosoft Professional software (version 2017) by DIAS Infrared Systems GmbH. First, an area of interest in x- and time direction was defined according to the maximum measured temperature TM,max,i of each entire measurement i for i = 1n (n: number of samples; in this investigation n = 3 per parameter set). The area had a length of 150 ms in time direction starting 50 ms before TM,max,i and a width of 2.4 mm in every x-direction defined in dependence of the seam width of the samples. Using MATLAB, a compensation polynomial Tpoly(t)i was fitted into the local measured temperature-time curve TM(t)i in the melt pool for every x-position (cf. Fig. 4). A polynomial temperature-time curve with an increasing progression until a maximum value and then falling progression of the temperature without fluctuations is assumed as the ideal curve because it means a steady temperature-time curve where the maximum values are predictable and adjustable according to the melting temperature of the substrate material.

Fig. 4
figure 4

Example for a local temperature-time curve with the corresponding fitting polynomial and the maximum temperature of the polynomial

Secondly, the maximum value of the compensation polynomial Tmax,poly(x)i and the mean square deviation TMSD(x)i between the temperature-time curve and the polynomial were calculated for each x-position. Figure 4 presents an example for the evaluation of the local temperature-time curve with the equation used for the calculation of the mean square deviation.

Thirdly, the ratios of the maximum values (temperature ratio Rquo(x)i) of the polynomials Tmax,poly(x)i and the maximum value of all polynomials Tmax,poly,i (cf. Eq. 1) were calculated and plotted as a function of the x-position (cf. Fig. 5). The x-position of the maximum measured temperature TM,max,i of the entire temperature measurements of each sample was set as origin of the x-axis (x = 0).

Fig. 5
figure 5

Measurement of the local temperature profile; the values are detected in relation to a constant emissivity of 0.3

$$ {R}_{quo}{(x)}_i=\frac{T_{\mathit{\max}, poly}{(x)}_i}{T_{\mathit{\max}, poly,i}} $$
(1)

The measurements were evaluated separately and combined to calculate the average temperature ratio Rquo(x) and the average mean square deviation TMSD(x) as well as the average temperature ratio \( \overline{R_{\mathrm{quo}}} \) and the average mean square deviation \( \overline{T_{\mathrm{MSD}}} \) across a defined area x1 of the x-position for the different parameter sets. Table 2 shows an overview of the different steps of the evaluation of the temperature measurements.

Table 2 Overview of the different steps of the evaluation of the temperature measurements

3 Results

Figure 6 shows the local temperature-time curve for a reference sample without laser beam oscillation. The temperature-time curve shows a stationary temperature field with maximum temperatures in the middle of the melt pool. The temperature decreases towards the edge of the melt pool. The presented temperature-time curve is located across the x- value of the maximum temperature of the entire measurement TM,max,i. It presents a homogenous curve with temperature deviations up to 100 K. The mean square deviation of the temperature-time curve and the polynomial is 83 K.

Fig. 6
figure 6

Measurement result of the reference sample without oscillation at a constant emissivity of 0.3

Figure 7 presents typical temperature-time curves resulting for the three different oscillation patterns at an oscillation frequency of 200 Hz and an oscillation width of 1.2 mm (oscillation amplitude 0.6 mm). The position of the maximum measured temperature is marked by a black cross in the temperature measurement. The maximum temperatures of the circular oscillation pattern are lower than those for the linear and eight-shaped oscillations. All measurements show repetitive local temperature fluctuations visible as different coloured regions in the temperature-time curve. The circular movement has the longest temporal expansion of red and green areas, whereas the linear oscillation pattern has the shortest. The local temperature of the circular oscillation pattern fluctuates more than the linear and eight-shaped oscillation patterns, indicated by the blue temperature areas between the repetitive red temperature areas.

Fig. 7
figure 7

Measurement results for the three different oscillation patterns at an oscillation width of 1.2 mm and an oscillation frequency of 200 Hz at an emissivity of 0.3

Figure 8 shows the temperature-time curve and fitted polynomial for an exemplary sample with laser beam line oscillation. The deviations between the polynomial and the temperature-time curve are larger than for the measurement without oscillation (cf. Fig. 6). The illustrated temperature-time curve is located across the maximum measured temperature TM,Max,i of the entire measurement. It shows repeating temperature peaks. The local temperature-time curves of all samples with beam oscillation show these repeating temperature peaks. The local temperature fluctuations that are up to 900 K. The temporal frequency of the temperature fluctuations matches the adjusted oscillation frequency. The temperature differences tend to decrease slightly with increasing oscillation frequency.

Fig. 8
figure 8

Temperature measurement across the maximum measured temperature and the fitted polynomial for a sample with laser beam line oscillation

Figure 9 shows the values of the temperature ratio Rquo,i of the polynomials across the x-direction. The asymmetry of the curves results from the orientation of the pyrometer which had an angle of 45° to the sample surface. The illustrated values are the average values and the standard deviations of the three measurements per parameter set. The curve for the measurements without oscillation is steeper than for the measurements with oscillation. For the samples with oscillation, the circular oscillation has the widest area of high temperature ratios, while the linear oscillation pattern has the narrowest.

Fig. 9
figure 9

Temperature ratio across the position in the x-direction (transversal to the brazing direction). The values are calculated as average value of the three measured samples per parameter set. The origin of the x-axis (x = 0) is positioned at the local temperature-time curve with the maximum measured temperature TM,max

4 Discussion

The repeating temperature fluctuations of the measurements with oscillation had local temperature differences of several 100 K. The highest temperatures were measured at the position of the laser spot whereas afterwards the temperature decreased significantly. The measurements without oscillation had clearly flatter local temperature fluctuations. The appearance of repeating temperature peaks is caused by the multiple local passes of the laser beam by combining a high oscillation frequency with a significant lower brazing velocity. The number of multiple local laser passes depends on the ratio of oscillation frequency and brazing speed, the oscillation pattern and the oscillation size. The temperature differences resulted from the typical high temperature gradients of keyhole processes [5]. The localised energy input caused a high temperature in the keyhole with a high temperature gradient in the vicinity. Therefore, the temperature is significantly higher near the laser beam and decreases after the laser pass by heat conduction and convection in the melt pool. The increase of the oscillation frequency at constant brazing velocity increased the number of local laser passes and thus decreased the period of time between them (time interval). This decreased the time for the local cooling by heat conduction which decreased the range of the temperature fluctuations. However, the applied oscillation frequencies were not high enough for the compensation of the temperature fluctuations being generated by the keyhole formation.

The circular oscillation pattern had lower maximum temperatures and more decreasing temperatures between the laser passes, but it also had the largest temporal expansion of high temperatures transversal to the brazing direction. This behaviour is caused by the average beam velocity and the geometrical expansion of the circular movement (cf. Fig. 10). This oscillation pattern offers a high average beam velocity and the largest geometrical expansion of all oscillation patterns. A high-beam velocity results in a short local interaction time and therefore a low local heat input, which leads to lower maximum temperatures, as depicted in [18]. The special eight-shaped oscillation pattern has the same average beam velocity, but it also has turning points which resulted in lower local beam velocities and therefore higher time-averaged power densities and higher temperatures. The large geometrical expansion leads to a higher expansion of the heated area and therefore distance between the laser positions which extend the cooling process between the laser passes. The large geometrical distance also results in a larger temporal expansion of high temperatures because the laser passes the observed region sooner and leaves later than in the other oscillation patterns.

Fig. 10
figure 10

Geometrical expansion of the three applied oscillation strategies with the calculated average beam velocity at an oscillation width of 1.2 mm and an oscillation frequency of 200 Hz

To rate the different oscillation parameters and the samples without oscillation, the mean values for the mean square deviation TMSD,x and the temperature ratios Rquo,x were calculated across a defined width x1 of the measurement (cf. Fig. 11). The results are evaluated referring to their homogeneity. The ideal homogenous temperature-time curve is assumed as a smooth polynomial local temperature-time curve over time in combination with a constant temperature over the width (and therefore a high temperature ratio), as illustrated in Fig. 11 on the left side. A homogenous temperature distribution over the width with only one temperature peak would be ideal to predict the temperature field and prevent melted areas in the substrate especially when the differences between the melting temperature of the brazing and substrate material would be smaller in case of other material combinations. Therefore, the results are evaluated and compared referring to an ideally homogenous temperature distribution, in which the mean value \( \overline{R_{\mathrm{quo}}} \) is 1 whereas \( \overline{T_{\mathrm{MSD}}} \) is 0.

Fig. 11
figure 11

Calculation of the rating parameters

Figure 12 shows the results of \( \overline{R_{\mathrm{quo}}} \) and \( \overline{T_{\mathrm{MSD}}} \) for the different tested parameters. The values are averaged across the three measurements (three samples) of each parameter set, and the results are illustrated graphically. The assumed ideal temperature distribution is marked with a green cross. None of the tested oscillation patterns result in a homogenous temperature field. The samples without oscillation have a nearly polynomial temperature-time curve over time but a high temperature gradient over the width in x-direction. The samples with oscillation have a better distribution of the temperature in x-direction but an unsteady curve of the local temperature over time. The mean square deviation between the polynomial and the local temperature-time curve decreases with increasing frequency, because of the decreasing of the temperature peaks. This decreases the differences between the polynomial and the measured temperature-time curve. The homogenisation increases with increasing frequency. Therefore, it could be assumed that substantially higher oscillation frequencies are necessary to obtain a more homogenous temperature field. The applied two-dimensional oscillation patterns, namely, the circular and special eight-shaped oscillation, cause more homogenous temperature distributions across the cross section, demonstrated by a higher \( \overline{R_{\mathrm{quo}}} \), than the linear oscillation pattern. The highest values of \( \overline{R_{\mathrm{quo}}} \) were observed for the circular-pattern. This implies that oscillation patterns with constant beam velocities have more homogenous temperature fields, as suspected from the results of Wang et al. [19]. Turning points of the laser beam during oscillation lead to higher local energy inputs and therefore local temperatures. Thus, the homogeneity of the temperature distribution is lower in comparison with movements without turning points.

Fig. 12
figure 12

Comparison of the properties of the temperature distributions of the different tested parameters using the developed key parameters for the homogeneity of the temperature field

The height of the temperature fluctuation decreases when increasing the frequency but only slightly. The tested oscillation frequencies were not sufficient for the formation of a complete homogenous temperature field. Substantially higher frequencies would, therefore, be necessary. The applied scan optic was not able to apply significantly higher frequencies by using the applied oscillation strategies and widths (= size of the pattern).

5 Conclusions

The influence of the laser beam oscillation on the temperature field in laser brazing with keyhole formation has been analysed. Adjusting the oscillation frequency and the oscillation pattern modifies the local temperature-time curve. The results were evaluated according to the homogeneity of the temperature field on the seam surface which has been characterised by two novel key factors.

On the basis of this study, it can be concluded for keyhole brazing with beam oscillation that:

  • The oscillation pattern mainly influences the temperature ratio \( \overline{R_{\mathrm{quo}}} \) which quantifies the temperature distribution transversal to the brazing direction by varying the local beam velocity and the area of heat input.

  • The oscillation frequency mainly influences the mean square deviation \( \overline{T_{\mathrm{MSD}}} \) which quantifies the temporal local temperature-time curve by varying the time interval between the local laser passes.

  • A circular oscillation pattern with a high oscillation frequency results in more homogenous temperature fields on the seam surface during keyhole brazing than line and eight-shaped patterns or lower frequencies.