Abstract
This study was performed to assess the clinical results of meniscus refixation using biodegradable Clearfix meniscal screws. Between July 1999 and June 2001 this technique was performed on 65 patients, of whom 60 (27 women, 33 men; 92%) were followed up by clinical examination after an average of 18 months (range 8–34). The average age of the patients at the time of surgery was 30 years (15–58). Two patients had already undergone a partial meniscectomy at the time of follow up; three patients had had a recurrence of typical clinical signs of a meniscal tear. The other 55 patients rated the overall clinical result as "excellent" (n =21), "good" (n =31) or "satisfactory" (n =3). The average Lysholm score [20] at the time of examination was 93 (49–100) points. The Tegner-Lysholm activity grade [29] preinjury was 5.6 (3–9), compared to a grade of 5.1 (3–9) at the follow-up examination. As a result of our study, biodegradable screws can be recommended as fixation devices with a high rate of good and excellent clinical results.
Similar content being viewed by others
References
Albrecht-Olsen P, Christensen G, Burgaard P, Joergensen U, Toerholm C (1999) The arrow versus horizontal suture in arthroscopic meniscus repair. A prospective randomized study with arthroscopic evaluation. Knee Surg Sports Traumatol Arthrosc 7:268–273
Arnoczky SP (1992) Gross and vascular anatomy of the meniscus and its role in meniscal healing, regeneration, and remodeling. In: Mow VC, Arnoczky SP, Jackson DW (eds) Knee meniscus: basic and clinical foundations. Raven Press, New York
Arnoczky SP, Lavagnino M (2001) Tensile fixation strengths of absorbable meniscal repair devices as a function of hydrolysis time. An in vitro experimental study. Am J Sports Med 29:118–123
Asahina S, Muneta T, Yamamoto H (1996) Arthroscopic meniscal repair in conjunction with anterior cruciate ligament reconstruction: factors affecting the healing rate. Arthroscopy 12:541–545
Asik M, Sener N (2002) Failure strength of repair devices versus meniscal suturing techniques. Knee Surg Sports Traumatol Arthrosc 10:25–29
Barber FA, Herbert MA (2000) Meniscal repair devices. Arthroscopy 16:613–618
Becker R, Schroder M, Starke C, Urbach D, Nebelung W (2001) Biomechanical investigations of different meniscal repair implants in comparison with horizontal sutures on human meniscus. Arthroscopy 17:439–444
Boenisch UW, Faber KJ, Ciarelli M, Steadmann JR, Arnoczky SP (1999) Pull-out strength and stiffness of meniscal repair using absorbable arrows or Ti-Cron vertical and horizontal loop sutures. Am J Sports Med 27:626–631
Buseck MS, Noyes FR (1991) Arthroscopic evaluation of meniscal repairs after anterior cruciate ligament reconstruction and immediate motion. Am J Sports Med 19:489–494
Cannon WD, Vittori JM (1992) The incidence of healing in arthroscopic meniscal repairs in anterior cruciate ligament-reconstructed knees versus stable knees. Am J Sports Med 20:176–181
De Haven KE (1999) Meniscus repair. Am J Sports Med 27:242–250
Dervin GF, Downing KJ, Keene GC, McBride DG (1997) Failure strength of suture versus biodegradable arrow for meniscal repair: an in vitro study. Arthroscopy 13:296–300
Eggli S, Wegmuller H, Kosina J, Huckell C, Jakob RP (1995) Long term results of arthroscopic meniscal repair. An analysis of isolated tears. Am J Sports Med 23:715–720
Fairbank TJ (1948) Knee joint changes after meniscectomy. J Bone Joint Surg 30:664–670
Horibe S, Shino K, Maeda A, Nakamura N, Matsumoto N, Ochi T (1996) Results of isolated meniscal repair evaluated by second look arthroscopy. Arthroscopy 12:150–155
Hurel C, Mertens F, Verdonk R (2000) Biofix resorbable meniscus arrow for meniscal ruptures: results of a 1-year follow-up. Knee Surg Sports Traumatol Arthrosc 8:46–52
King D (1936) The healing of semilunar cartilages. J Bone Joint Surg 18:333–342
Kohn D, Siebert W (1989) Meniscus suture techniques: a comparative biomechanical cadaver study. Arthroscopy 5:324–327
Lavagnino M, Arnoczky SP (2000) Fixation strength of absorbable meniscus repair devices as a function of hydrolysis time: an in vitro experimental study. Trans Orthop Res Soc 46:795
Lysholm J, Gillquist J (1982) Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale. Am J Sports Med 10:150–154
Morgan CD, Casscells SW (1986) Arthroscopic meniscus repair: a safe approach to the posterior horns. Arthroscopy 2:3–12
Morgan CD, Woitys EM, Casscells CD, Casscells SW (1991) Arthroscopic meniscal repair evaluated by second-look arthroscopy. Am J Sports Med 19:632–637
Muellner T, Egkher A, Nikolic A, Funovics M, Metz V (1999) Open meniscal repair: clinical and magnetic resonance imaging findings after twelve years. Am J Sports Med 27:16–20
Outerbridge RE (1961) The etiology of chondromalacia patellae. J Bone Joint Surg 43:752–757
Rupp S, Seil R, Kohn D (2001). Meniscus repair. Review of the literature. Arthroskopie 14:267–275
Rühmann O, Kohn D, Sander-Beuermann A (1996) Arthroscopic medial meniscal repair—injury of the saphenous nerve and its avoidance. Arthroskopie 9:281–284
Scott GA, Jolly BL, Henning CE (1986) Combined posterior incision and arthroscopic intraarticular repair of the meniscus. An examination of factors that affect healing. J Bone Joint Surg Am 68:847–861
Seil R, Rupp S, Kohn D (2000) Cyclic testing of meniscal sutures. Arthroscopy 16:505–510
Tegner Y, Lysholm J (1985) Rating systems in the evaluation of knee ligament injuries. Clin Orthop 198:43–49
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bohnsack, M., Börner, C., Schmolke, S. et al. Clinical results of arthroscopic meniscal repair using biodegradable screws. Knee Surg Sports Traumatol Arthrosc 11, 379–383 (2003). https://doi.org/10.1007/s00167-003-0411-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00167-003-0411-6