1 Introduction

Wood modification is a well-established technology to improve biological durability, dimensional stability, hardness and weathering resistance of wood (Hill 2006). Besides these advantages, modification can alter the adhesive strength due to changes in chemical, physical and structural properties of wood. The less polar and less porous modified wood surfaces may lead to reduced adhesion due to poorer adhesive wetting of the wood and fewer chemical bonds between the two surfaces (Hunt et al. 2007). On the other hand, improved bonding performance can be achieved as the improved dimensional stability of modified wood results in less shrinking and swelling stresses on the cured adhesive bond (Sernek et al. 2008).

The great variety of wood adhesives, species, and modification methods (chemical, thermal) makes the bonding behaviour of modified wood a complex subject. Acetylation of wood has been shown to affect bonding strength depending on the type of adhesive (Vick and Rowell 1990; Vick et al. 1993; Frihart et al. 2004). The additional hydroxyl groups being available for hydrogen-bonding with the adhesive provided by oxide modifications with butylene and propylene oxide did not give superior adhesion over wood that was acetylated (Brandon et al. 2005). Furfurylated wood could be glued satisfactorily with two different gluing systems even though the percentage glue line failure increased under wet conditions (van der Zee et al. 2007). The poor bonding properties of silicone modified wood were improved by using hydroxymethylated resorcinol as a coupling agent (Kurt et al. 2008). Heat treatment of wood was also reported to affect the glueability of wood in several ways depending on the adhesive type used (Boonstra et al. 1998; Sernek et al. 2008; Sahin Kol et al. 2009).

Impregnation of wood with water soluble, low molecular weight phenol–formaldehyde (PF) resin systems has been researched since the 1930s with main purpose to increase the dimensional stability of solid wood as well as of the commercial plywood composites Impreg and Compreg (Stamm 1959; Hill 2006; Gabrielli and Kamke 2010). Phenol–formaldehyde resins were shown to penetrate and bulk the cell wall (Stamm and Seborg 1936; Rowell and Banks 1985). Ohmae et al. (2002) obtained anti-shrink efficiencies (ASE) up to 74 at 30 % weight percent gain (WPG) using a low molecular weight PF due to both bulking and cross-linking of the cell wall. PF modification has also been shown to enhance the resistance against white rot and brown rot fungi (Ryu et al. 1991). The effectiveness of modification was shown to depend on the penetration of phenol formaldehyde resins into wood cell walls (Ryu et al. 1993; Furuno et al. 2004).

With new modification processes becoming commercially available and increasing use of modified wood for exterior and interior applications, it is important to continuously update our knowledge on adhesive bonding of modified wood. PF modification has a good chance of commercialisation due to the enhanced wood properties, the relatively low price of PF resin and the relatively easy feasibility of the process. The aim of this study was to evaluate the bonding performance of phenol formaldehyde modified wood glued with two adhesive systems, phenol resorcinol formaldehyde and polyvinyl acetate. The tensile shear bond strength and penetration of adhesives into the porous wood structure were examined.

2 Materials and methods

2.1 Treatment

Defect-free assembly wood blocks of beech (Fagus sylvatica L.) with dimensions 600 (longitudinal) × 130 × 6 mm3 and average density of 680 kg m−3 at 12 % moisture content were used for the study. The angle between the growth rings and the surface to be bonded was kept between 30° and 90°. The wood blocks were treated with phenol formaldehyde (PF) with sodium hydroxide added in an aqueous solution with two different concentrations: 10 and 25 % based on the solid content of PF. PF was provided by Cytec Surface Specialties GmbH & Co. KG (Wiesbaden, Germany) with average molecular weight 408 g mol−1 (determined by gel permeation chromatography using polystyrene standards), specific gravity 1.15 g cm−3, viscosity 2.760 mPa s at 23 °C, and 78 % solid content. The treatment was conducted in a stainless steel vessel involving a vacuum (100 mbar for 1 h) and a pressure phase (12 bar for 2 h). The wood blocks were then cured gradually from 40 to 120 °C in an oven for a total duration of 11 days. After curing, the blocks were conditioned at 20 °C and 65 % RH in a climate chamber to reach equilibrium moisture content.

2.2 Gluing

Phenol resorcinol formaldehyde PRF (Prefere 4040 with 20 % hardener; Dynea GmbH, Erkner, Germany) and polyvinyl acetate PVAc (Ponal Super 3 with 15 % D4 hardener; Henkel AG & Co., Düsseldorf, Germany) were spread uniformly on the wood blocks by hand brushing. Pressing of the assemblies was carried out for 120 min in a hydraulic press at room temperature and at a pressure of 1.5 N mm−2. Block shear specimens were cut from the assemblies and randomly assigned to either the dry or wet shear tests. Before testing all specimens were conditioned at 20 °C and 65 % RH in a climate chamber for 7 days. Specimens for the wet shear test were further soaked in water at 15 ± 5 °C for 4 days and tested in the wet state. The measurement of longitudinal shear strength was carried out in a Zwick/Roell Z010 universal testing machine according to the European Standard (1992) EN 302-1. Ten replicates were used for each adhesive and treatment.

2.3 Adhesive penetration

To observe the adhesive penetration into the porous wood structure, 20–30 μm thick sections exposing a bondline with a cross-sectional surface at various longitudinal positions of the specimens were cut on a Reichert-Jung sliding microtome. The sections were placed on glass slides, unstained for PRF bondlines and after staining with a pipette drop of 0.5 % safranin O solution for PVAc bondlines. PVAc sections were examined under an Eclipse 50i fluorescence microscope with appropriate filter sets, equipped with a Sight DS-5M-L1 digital camera (both Nikon, Düsseldorf, Germany), while conventional light microscopy was applied for PRF sections by using the same microscope. Penetration depth of the adhesive was measured on 25 positions along 130 mm of bondline for each section.

3 Results

Table 1 presents tensile shear strength and wood failure data results obtained for each adhesive. Under both dry and wet condition, PRF adhesive produced higher shear strengths and wood failure percentages than PVAc irrespective of the pre-treatment. In the dry test, bonding strength remained unchanged after modification with PF except for the specimens modified with 25 % concentration when glued with PVAc; these showed a significantly lower strength of 6.13 N mm−2 (ANOVA and Tukey HSD test, P = 5 %). This combination also gave the lowest wood failure percentage (40 %), while wood failure percentages of 80–90 % for all other cases verify the acceptable bonds produced by the PF-treated wood under dry conditions. Under wet conditions, PVAc bonds weakened considerably giving almost zero shear strength values (0.15–0.60 N mm−2) for PF-modified wood and correspondingly very little wood failure (10 %). Exposure to water-soaking almost halved the bonding strength of 10 % PF-modified and PRF-bonded samples but had no statistically significant effect for 25 % PF pre-treatment (t test, P = 5 %). Differences in wood failure percentages between the dry and wet condition were in agreement with the shear strength data for the PRF adhesive. Improved adhesion with PRF adhesive in wet conditions could be obtained with increasing PF concentration. The 25 % PF treated samples showed higher wood failure (70 %) and strength (8.58 N mm−2) than the 10 % PF-treated ones (respective values were 40 % and 5.97 N mm−2; for shear strength, differences were statistically significant using Tukey’s analysis at P = 5 %). However, shear strength of modified wood in each concentration did not differ significantly when compared to unmodified wood (ANOVA and Tukey HSD test, P = 5 %).

Table 1 Tab. 1 Bonding strength of beech wood modified with phenol formaldehyde (PF)Klebefestigkeit von mit Phenol-Formaldehyd (PF) behandeltem Buchenholz

For all treatments and adhesive types, a discontinuous interphase (e.g. volume in which both wood cells and adhesive are present) was seen further away from the bondline (Fig. 1). Penetration was dominated by flow through the vessels and appeared either as total or partial filling of the lumens. The observations of this study did not reveal any evidence of adhesive flow in the rays while penetration of adhesive into the fibres and axial parenchyma was limited to only very few cells (1–3) near the bondline. PVAc penetration in the vessels could be observed up to a distance of approximately 200 μm from the contact area between the wood surface and the adhesive for the control and the 10 % PF-modified specimen, while in the case of pre-treatment with 25 % PF penetration depth was limited up to approximately 130 μm. Similar observations were made for the PRF adhesive in 25 % PF-modified specimens presenting the lower penetration depth (approx. 160 μm). Control and 10 % PF-modified samples showed comparable average penetration values of approximately 240 and 220 μm, respectively. Deposition of the PF resin into the cell wall and lumens as well as its hydrophobation effect (Furuno et al. 2004) affected adhesive penetration at 25 % PF concentration but resulted in significant lower adhesion only for PVAc.

Fig. 1 Abb. 1
figure 1

Transverse view of horizontal bondlines in beech wood modified with phenol formaldehyde in 10 % (a, c) and 25 % concentration (b, d) using fluorescence light for PVAc (a, b) and visible light for PRF adhesive (c, d). Scale bars: 500 μm

Querschnitt der horizontalen Klebstoffschicht von Buchenholz, das mit 10%iger (a, c) und 25%iger Phenol-Formaldehyd-Lösung modifiziert wurde, wobei zur Detektion von PVAc Fluoreszenzlicht (a, b) und von PRF-Klebstoff sichtbares Licht (c, d) verwendet wurde. Maßstabsskala: 500 μm

4 Conclusion

The bonding performance of PF modified beech wood using PVAc and PRF adhesives was examined in this study. PRF adhesive causes higher shear strength than PVAc under both dry and wet condition. PF modified wood can be bonded satisfactorily with the two adhesive systems under dry conditions with the exception of wood modified with 25 % PF solution and PVAc adhesive. PVAc adhesive should be avoided for gluing of PF modified wood to be used for exterior applications as water-soaking results in almost zero shear bond strength and very little wood failure. In exterior applications, the structural adhesive PRF and wood modified with high PF concentration was the best combination to achieve optimal bonding performance. For both adhesives, the penetration into the porous wood structure is the lowest at highest degree of PF modification.