The effects of tissue ingrowth on the compliance of porous Dacron grafts were studied in 8 mm external-velour warp-knit Dacron grafts implanted in the canine descending thoracic aorta. The compliance of these grafts was measured before implantation and after implant periods of two weeks and one, two, four, and six months. Compliance, which initially was 0.043 ± 0.008% mm Hg, decreased less than 10% after implantation (no statistical difference at p < 0.05). No anastomotic neointimal hyperplasia was observed. Although the total thickness of the graft wall increased two- to three-fold after implantation, the benign healing process observed in this study had very little influence on graft compliance followed to six months.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. PAASCHE PE, KINLEY CE, DOLAN FG, GONZA ER, MARBLE AE. Consideration of suture line stresses in the selection of synthetic grafts for implantation.J Biomechanics 1973;6:253–259.

    Article  CAS  Google Scholar 

  2. GONZA ER, MASON WF, MARBLE AE, WINTER DA, DOLAN FG. Necessity for elastic properties in synthetic arterial grafts.Can J Surg 1974;77:176.

    Google Scholar 

  3. BAIRD RN, KIDSON IG, L’ITALIEN GJ, ABBOTT WM. Dynamic compliance of arterial grafts.Am J Physiol 1977;233:568–572.

    Google Scholar 

  4. KIDSON IG, ABBOTT WM. Low compliance and arterial graft occlusion.Circulation 1978;58(suppl):1–4.

    Google Scholar 

  5. KINLEY CE, MARBLE AE. Compliance: a continuing problem with vascular grafts.J Cardiovasc Surg 1980;21:163–170.

    CAS  Google Scholar 

  6. WALDEN R, L’ITALIEN GJ, MEGERMAN J, ABBOTT WM. Matched elastic properties and successful arterial grafting.Arch Surg 1980;115:1166–1169.

    CAS  PubMed  Google Scholar 

  7. MADRAS PN, WARD CA, JOHNSON WR, SINGH PI. Anastomotic hyperplasia.Surgery 1981;90:922–923.

    CAS  PubMed  Google Scholar 

  8. CENGIZ M, SAUVAGE LR, BERGER K, ROBEL SB, ROBEL V, WU H-D, WALKER M, APPLEYARD RF, WOOD SJ. Effects of compliance alteration on healing of a porous Dacron prosthesis in the thoracic aorta of the dog.Surg Gynecol Obstet 1984;158:145–151.

    CAS  PubMed  Google Scholar 

  9. MEGERMAN J, ABBOTT WM. Compliance in vascular grafts. In CB Wright, ed. Vascular grafting, Boston: John Wright, PSG Inc. 1983: 344–364.

    Google Scholar 

  10. HASSON JE, MEGERMAN J, ABBOTT WM. Postsurgical changes in arterial compliance.Arch Surg 1984;119:788–791.

    CAS  PubMed  Google Scholar 

  11. NIH Publication No. 80-23, revised 1978.

  12. YATES SG, BARROS D’SA AAB, BERGER K, FERNANDEZ LG, WOOD SJ, RITTENHOUSE EA, DAVIS CC, MANSFIELD PB, SAUVAGE LR. The preclotting of porous arterial prostheses.Ann Surg 1978;188:611–622.

    Article  CAS  PubMed  Google Scholar 

  13. MATHISEN SR, WU H-D, SAUVAGE LR, USUI Y, WALKER MW. An experimental study of eight current arterial prostheses.J Vasc Surg 1986;4:33–41.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

About this article

Cite this article

Usui, Y., Goff, S.G., Sauvage, L.R. et al. Effect of healing on compliance of porous dacron grafts. Annals of Vascular Surgery 2, 120–126 (1988). https://doi.org/10.1007/BF03187561

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03187561

Key Words

Navigation