Skip to main content
Log in

Mass transfer characteristics and overall mass transfer coefficient in the ozone contactor

  • Published:
Korean Journal of Chemical Engineering Aims and scope Submit manuscript

Abstract

The overall mass transfer coefficient kLa,F in the flow characteristics was determined by the measurement of the diffusivity of ozone, density of aqueous solution, and viscosity. However, the measured values kLa,F in the range of 0.0096–0.0622 min-1 show large changes in hydraulic retention time, and the dissolved ozone concentration CL,F presented under 0.1 mg/l is lower than the dissolved ozone observed. The overall mass transfer coefficient kLa,M in the ozone decomposition was determined by measurement of the equilibrium dissolved ozone, overall decomposition rate constant, and overall Henry’s law constant. The measured values kLa,M are in the range of 0.0441–0.0749 min-1, and they present small changes depending on the hydraulic retention time. Furthermore, the measured dissolved ozone concentration CL,M presents a larger value than the CL,F. Then, the kLa,M is selected as an input overall mass transfer coefficient to predict the dissolved ozone requirement in the ozone contactor.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bingham,Fluidity and Plasticity, McGraw-Hill, New York, 340 (1922).

    Google Scholar 

  • Carphentier, J. C.,Advances in Chemical Engineering, Academic Press,11, New York (1981).

    Google Scholar 

  • Choi, K.H. and Lee, W.K., “Behavior of Gas Bubbles in a Concentric Cylindrical Airlift Column,”Korean J. Chem. Eng.,9, 66 (1992).

    Article  CAS  Google Scholar 

  • Choi, K.H., “Hydrodynamic and Mass Transfer Characteristics of External-Loop Airlift Reactors without an Extension Tube above the Downcomer,”Korean J. Chem. Eng.,18, 240 (2001).

    Article  CAS  Google Scholar 

  • Clesceri, L. S., Greenburg, A. E., Trussel, R. R. and Franson, M.A.H.,Standard Methods for the Examination of Water and Wastewater, 16th Ed., APHA, AWWA, and WPCF, 399 (1985).

  • Danckwerts, P.V.,Gas-liquid Reaction, McGraw-Hill, New York, 17 (1970).

    Google Scholar 

  • Kang, Y., Min, B. T., Nah, J. B. and Kim, S.D., “Effect of Floating Bubble Breakers on Gas Phase Holdup, Axial Dispersion and Mass Transfer in Continuous Bubble Columns,”HWAHAK KONGHAK,28, 560 (1990).

    CAS  Google Scholar 

  • Kang, Y. S., Kim, J.W. and Lee, W.K., “Gas Holdup and Volumetric Mass Transfer Coefficient in a Bubble Column with Draft Tube,”HWAHAK KONGHAK,24, 371 (1986).

    CAS  Google Scholar 

  • Koh, J. C., Kim, B. S., Lee, J. M. and Rhee, B. S., “Gas Holdup and Volumetric Mass Transfer Coefficient in Slurry Bubble Column of Acicular Goethite Suspension [I],”HWAHAK KONGHAK,27, 23 (1989).

    CAS  Google Scholar 

  • Lee, J. E., Choi, W. S. and Lee, J.K., “A Study of the Bubble Properties in the Column Flotation System,”Korean J. Chem. Eng.,20, 943 (2003).

    Google Scholar 

  • Lee, J. E. and Lee, J.K., “Effect of Microbubbles and Particle Size on the Particle Collection in the Column Flotation,”Korean J. Chem. Eng.,19, 703 (2002).

    Article  CAS  Google Scholar 

  • Park, H. S., Hwang, T. M., Oh, H. J. and Kang, J.W., “Characterization of Water for the Ozone Application Measuring Ozone Consumption Rate,”Korean Society of Env. Eng. J.,23, 1125 (2001).

    Google Scholar 

  • Rhim, J.A., “Decomposition Characteristics and Overall Decomposition Rate Constant of Dissolved Ozone,”Korean Society of Env. Eng. J.,25, 1394 (2003).

    Google Scholar 

  • Sotelo, J. L., Beltran, F. J., Benitez, F. J. and Beltran-Heredia, J., “Henry’s Law Constant for the Ozone-Water System,”Wat. Res.,23, 1239 (1989).

    Article  CAS  Google Scholar 

  • Yoon, J.H.,Decomposition of Microcystin-LR by Ozonation in Cylindrical Reactor, Ph. D. Dissertation, Pusan National University (1999).

  • Yoon, J.H., Rhim, J. A., Kim, Y. T., Park, T. J. and Kim, D.Y., “Decomposition Characteristics of Microcystin-LR by Ozonation,”Korean Society of Env. Eng. J.,21, 711 (1999).

    Google Scholar 

  • Zhou, H. and Smith, D., “Ozone Mass Transfer in Water and Wastewater Treatment: Experimental Observation using a 2D Laser Particle Dynamics Analyzer,”Wat. Res.,34, 909 (2000).

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jung A Rhim.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rhim, J.A., Yoon, J.H. Mass transfer characteristics and overall mass transfer coefficient in the ozone contactor. Korean J. Chem. Eng. 22, 201–207 (2005). https://doi.org/10.1007/BF02701485

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02701485

Key words

Navigation