Abstract
A dynamometer is designed and fabricated to measure the force output during static and dynamic muscle actions of the plantar flexor muscles of anaesthetised rats in vivo. The design is based on a computer-controlled DC servomotor capable of angular velocities in excess of 17.5 rad s−1. The system controls the range of motion, angular velocity and electrical stimulation of the muscles, while monitoring the force output at the plantar surface of the foot. The force output is measured by a piezo-electric load cell that is rated at 5 kg capacity. Angular velocity and position are measured by a DC tachometer and potentiometer, respectively. All measurement devices are linear (r2=0.9998). The design minimises inertial loading during high-speed angular motions, with a variation in force output of less than 0.2%. The dynamometer proves to be an accurate and reliable system for quantifying static and dynamic forces of rat plantar flexor muscles in vivo.
Similar content being viewed by others
References
Ashton-Miller, J. A., Youda, H., Veerichetty, A. K., McCubbrey, D. A., andFaulkner, J. A. (1992): ‘An apparatus to measurein vivo biomechanical behavior of dorsi and plantar flexors of the mouse ankle’,J. Appl. Physiol.,72, pp. 1205–1211
Bahler, A. S., Fales, J. T. andZierler, K. L. (1968): ‘The dynamic properties of mammalian skeletal muscle’,J. Gen. Physiol.,51, pp. 369–384
Farrell, M. andRichards, J. E. (1986): ‘Analysis of the reliability and validity of the kinetic communicator exercise device’,Med. Sci. Sports Exerc.,18, pp. 44–49
Faulkner, J. A. andJones, D. A. (1989): ‘Injury to skeletal muscles of mice by forced lengthening during contractions’,Q. J. Exper. Physiol.,74, pp. 661–670
Lewis, J. L., Lew, W. D. andSchmidt, J. (1982): ‘A note on the application and evaluation of the buckle transducer for knee ligament force measurement’,J. Biomech. Eng.,104, pp. 125–128
Lieber, R. L. andFriden, J. (1988): ‘Selective damage of fast glycolytic muscle fibers with eccentric contraction of the rabbit tibialis anterior’,Acta Physiol. Scand.,3, pp. 587–588
Nikolaou, P. K., MacDonald, B. L., Glisson, R. R., Seaber, A. V., andGarrett, W. E. (1987): ‘Biomechanical and histological evaluation of muscle after controlled strain injury’,Am. J. Sports Med.,15, pp. 9–14
Walmesley, B., Hodgson, J. A. andBurke, R. E. (1978): ‘Forces produced by medial gastrocnemius and soleus muscles’,J. Neurophysiol.,41, pp. 1203–1216
Warren, G. L., Hayes, D. A., Lowe, D. A. andArmstong, R. B. (1993): ‘Mechanical factors in the initiation of eccentric contraction induced injury of the rat soleus muscle’,J. Physiol. Lond.,464, pp. 457–475
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Cutlip, R.G., Stauber, W.T., Willison, R.H. et al. Dynamometer for rat plantar flexor musclesin vivo . Med. Biol. Eng. Comput. 35, 540–543 (1997). https://doi.org/10.1007/BF02525537
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02525537