Skip to main content
Log in

Integrating enconding systems for recording ionizing radiation. Oblique incidence of radiation

  • Measurements of Ionizing Radiation
  • Published:
Measurement Techniques Aims and scope

Abstract

An investigation is made of the influence of the factor of oblique incidence of radiation on the quality of reconstructed images when utilizing integrating encoding systems for measuring ionizing radiation with plane multipinhole encoding collimators. The results are given of a numerical calculation of an instrumental function which takes this factor into account. Four methods for compensating the factor of oblique incidence of radiation are considered. Recommendations are formulated for choosing the type and method of construction of the collimator used.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G. A. Fedorov and S. A. Tereshchenko,Izmerit. Tekh., No. 11, 49 (1995).

    Google Scholar 

  2. G. A. Fedorov and S. A. Tereshchenko,Izmerit. Tekh., No. 9, 50 (1996).

    Google Scholar 

  3. G. A. Fedorov and S. A. Tereshchenko,Izmerit. Tekh., No. 2, 44 (1997).

    Google Scholar 

  4. G. A. Fedorov and S. A. Tereshchenko,Izmerit. Tekh., No. 10, 49 (1997).

    Google Scholar 

  5. G. A. Fedorov and S. A. Tereshchenko,Izmerit. Tekh., No. 12, 50 (1998).

    Google Scholar 

  6. T. M. Cannon and E. E. Fenimore,Appl. Opt.,18, No. 7, 1052 (1979).

    Article  ADS  Google Scholar 

  7. G. A. Fedorov and S. A. Tereschenko,Computational Emssion Tomography [in Russian], Énergoatomizdat, Moscow (1990).

    Google Scholar 

  8. E. E. Fenimore and T. M. Cannon,Appl. Opt.,17, No. 3, 337 (1978).

    ADS  Google Scholar 

  9. G. A. Fedorov,Radiation Introscopy: Information Encoding and Experiment Optimization [in Russian], Énergoatomizdat, Moscow (1982).

    Google Scholar 

  10. S. R. Gottesman and E. J. Schneid,IEEE Trans. Nucl. Sci.,NS-33, No. 1, 745 (1986).

    Article  ADS  Google Scholar 

Download references

Authors

Additional information

Translated from Izmeritel'naya Tekhnika, No. 5, pp. 48–55, May, 1999.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Fedorov, G.A., Tereshchenko, S.A. Integrating enconding systems for recording ionizing radiation. Oblique incidence of radiation. Meas Tech 42, 479–489 (1999). https://doi.org/10.1007/BF02504473

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02504473

Keywords

Navigation