Skip to main content
Log in

Thermoanalytical control of paint-shop wastes prior to disposal

  • Published:
Journal of thermal analysis Aims and scope Submit manuscript

Abstract

The paint-shop wastes under study originated from metallurgical factory painting houses. Displaying a high toxicity and flammability, they are classified as specifically hazardous to the natural environment. Paint-shop wastes can be disposed of in the following ways:

  • solidification and deposition in sanitary landfills;

  • storage on a special dumping ground;

  • incineration.

This paper presents the physicochemical composition and thermal analysis (DTA and TG) of paint-shop wastes and their mixtures with various components.

Thermoanalytical measurements were carried out in a dynamic atmosphere of air. Enthalpies were calculated from the peak areas of the DTA curves. Thermoanalytical data were compared with calorimetric results obtained with an oxygen bomb.

Zusammenfassung

Die untersuchten Lackier-Abfälle kommen aus Lackierereien metallurgischer Fabriken. Wegen ihrer hohen Toxizität und Entflammbarkeit werden sie für die natürliche Umgebung als besonders gefährlich eingestuft. Lackiererei-Abfälle können auf folgende Weise entsorgt werden:

  • Verfestigung und Deponierung auf Ablagerungsplätzen

  • Lagern in Sondermülldeponien

  • Veraschung

In diesem Artikel wird die physikochemische Zusammensetzung und die Thermoanalyse (DTA und TG) beider Lackiererei-Abfälle und ihrer Gemische mit verschiedenen Komponenten beschrieben.

Die thermoanalytischen Messungen wurden in dynamischer Luftatmosphäre ausgeführt. Die Enthalpiewerte wurden anhand der Peakflächen der DTA Kurven berechnet. Die thermoanalytischen Angaben wurden weiterhin mit den kalorimetrischen Daten von einer Sauerstoffbombe verglichen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P. Balmer and B. Kaffehr, DTA for the characterization of the stability of sludges, Proc. of Sec. Europ. Symp. Vienna, 1980.

  2. M. J. A. Vennekens and C. R. I. Odding, Thermochim. Acta, 134 (1988) 445.

    Article  Google Scholar 

  3. E. S. Kempa, Scientific Papers of the Institute of Environmental Protection Engineering, Technical University of Wroclaw, 1976, p. 12.

  4. M. Sebastian and J. Dobosz, J. Thermal Anal., 33 (1988) 421.

    Article  Google Scholar 

  5. H. Lotze, Scientific Papers of Friedrich-Schiller University, Thermal Analysis in Industry and Science, Jena 1990.

  6. M. Odlyha, Thermochim. Acta, 134 (1988) 79.

    Article  Google Scholar 

  7. G. Lombardi, For better Thermal Analysis ICTA, Mat. Istituto di Mineralogie e Petrografia dell Università di Roma, 1980.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sebastian, M. Thermoanalytical control of paint-shop wastes prior to disposal. Journal of Thermal Analysis 38, 2087–2093 (1992). https://doi.org/10.1007/BF01979620

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01979620

Keywords

Navigation