Conclusions
-
1.
The accuracy of the readings of a point dynamometer depends upon the correct setting of the projection of the measuring pin.
-
2.
The optimal projection of the measuring pin can be determined by formulas (3) and (4).
-
3.
The accuracy of the measurement is higher, the smaller the diameter of the measuring pin for a given elastic element or smaller the deformation of the elastic element at a given diameter of the measuring pin, but not to the detriment of the sensitivity of the dynamometer.