A rapid and specific method for the determination of traces of thallium directly in urine by differential pulse anodic stripping voltammetry

  • Original Investigations
  • Published:
Archives of Toxicology Aims and scope Submit manuscript

Summary

The applicability of differential pulse anodic stripping voltammetry to the direct qualitative and quantitative analysis of thallium in urine has been investigated. Comparisons were made between the hanging mercury drop electrode and the mercury plated wax impregnated graphite electrode. The latter electrode was found to be somewhat more sensitive, with detection limits in the lower ppb range.

For quantitative determination, the hanging mercury drop electrode showed better reproducibility. The effects of toxicologically important metals on the analysis of thallium were investigated and their possible interference could be eliminated by a proper choice of operating conditions. The advantages of the proposed method are its sensitivity, speed and low cost in comparison with other methods for detecting and measuring thallium.

Zusammenfassung

Die Anwendung der inversen Pulsvoltammetrie mit Differenzstrom-Messung in der qualitativen und quantitativen Analyse von Thallium in Urin ist untersucht worden. Die hängende Quecksilbertropfenelektrode und die wachsimprägnierte Graphitelektrode mit einem Quecksilberfilmüberzug wurden verglichen.

Die letzte Elektrode ist empfindlicher mit einem Nachweisvermögen unterhalb 10−9 g Tl/ml Lösung.

Die hängende Quecksilbertropfenelektrode gibt aber eine größere Reproduzierbarkeit. Die Effekte anderer toxikologisch interessanter Elemente auf den Thallium-Nachweis sind untersucht worden, und mögliche Störungen konnten eliminiert werden durch die Wahl des Arbeitsverfahrens.

Das vorgestellte Verfahren hat die Vorteile, daß die Methode empfindlich und schnell ist mit geringem apparativem Aufwand im Vergleich mit anderen Methoden zum Thalliumnachweis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Ariel, M., Bach, D.: The determination of thallium in urine. Analyst 88, 30–33 (1963)

    Google Scholar 

  • Batley, G. E., Florence, T. M.: The evaluation and comparison of some techniques of anodic stripping voltammetry. J. Electroanal. Chem. 55, 23–43 (1974)

    Google Scholar 

  • Copeland, T., Skogerboe, R. K.: Anodic stripping voltammetry. Anal. Chem. 46, 1257A-1268A (1974)

    Google Scholar 

  • Curry, A. S., Read, J. F., Knott, A. R.: Determination of thallium in biological material by flame spectrophotometry and atomic absorption. Analyst 94, 744–753 (1969)

    Google Scholar 

  • Curtis, A. R.: Determination of trace amounts of thallium in urine, using the Mercury Film electrode and differential pulse anodic stripping voltammetry. Journal of the AOAC 57, 1366–1372 (1974)

    Google Scholar 

  • Eisner, U., Ariel, M.: Trace analysis by anodic stripping voltammetry III. Trace metal determination in biological media. J. Electroanal. Chem. 11, 26–30 (1966)

    Google Scholar 

  • Florence, T. M., Farrar, Y. J.: Removal of oxygen from polarographic solutions with ascorbic acid. J. Electroanal. Chem. 41, 127–133 (1973)

    Google Scholar 

  • Geldmacher-v. Mallinckrodt, M., Pooth, M.: Gleichzeitige spektrographische Prüfung auf 25 Metalle und Metalloïde in biologischem Material. Arch. Toxicol. 25, 5–18 (1969)

    Google Scholar 

  • Searle, B., Chan, W., Davidov, B.: Determination of lead in blood and urine by anodic stripping voltammetry. Clin. Chem. 19, 76–80 (1973)

    Google Scholar 

  • Siegerman, H., O'Dom, G.: Differential pulse anodic stripping of trace metals. American Laboratory, June 1972

  • Weinig, E., Zink, P.: Über die quantitative massenspektrometrische Bestimmung des normalen Thallium-Gehalts im Menschlichen Organismus. Arch. Toxicol. 22, 255–274 (1967)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Franke, J.P., Coenegracht, P.M.J. & de Zeeuw, R.A. A rapid and specific method for the determination of traces of thallium directly in urine by differential pulse anodic stripping voltammetry. Arch. Toxicol. 34, 137–143 (1975). https://doi.org/10.1007/BF00353314

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00353314

Key words

Schlüsselwörter

Navigation