Abstract
The performance of a single X-ray absorptiometry (SXA) device incorporating an X-ray tube as a photon source was evaluated with respect to precision in vivo and in vitro, scan time, image quality, and correlation with an existing dual energy X-ray absorptiometry (DXA) device. SXA precision in vivo, expressed as a coefficient of variation (CV), was 0.66% for bone mineral content (BMC) and 1.05% for bone mineral density (BMD). Precision in vitro, based on 78 BMC measurements of a forearm phantom over 195 days, was 0.53%. Correlation with DXA at the 8 mm distal forearm site was high (r=0.97 for BMC and r=0.96 for BMD). A preliminary SXA reference database composed of 151 healthy Caucasian American women was developed to facilitate the interpretation of patient measurements. SXA scan time was 4 minutes and delivered a radiation exposure of 1.68 mrem. SXA image quality and spatial resolution were superior to SPA and comparable to DXA.
Similar content being viewed by others
References
Sorenson JA, Cameron JR (1967) A reliable in vivo measurement of bone mineral content. J Bone Joint Surg Am 49:481–497
Cameron JR, Mazess RB, Sorenson JA (1968) Precision and accuracy of bone mineral determination by direct photon absorptiometry. Invest Radiol 3:141–150
Kelly TL, Slovik DM, Schoenfeld DA, Neer RM (1988) Quantitative digital radiography versus dual photon absorptiometry of the lumbar spine. J Clin Endocrinol Metab 67:839–844
Mazess RB, Collick B, Trempe J, Bardon HS, Hanson JA (1989) Performance evaluation of a dual-energy x-ray bone densitometer. Calcif Tissue Int 44:228–232
Lai KC, Goodsitt MM, Murano R, Chesnut CH III (1992) A comparison of two dual-energy absorptiometry systems for spinal bone mineral measurement. Calcif Tissue Int 50:203–208
Black DM, Cummings SR, Genant HK, Nevitt MC, Palermo L, Browner W (1992) Axial and appendicular bone density predicts fractures in older women. J Bone Miner Res 7:633–638
Cummings SR, Black DM, Nevitt MC, Browner WS, Cauley JA, Genant HK, Mascioli SR, Scott JC, Seeley DG, Steiger P, Vogt TM (1990) Appendicular bone density and age predict hip fracture in women. JAMA 263:665–668
Hui SL, Slemenda CW, Johnston CC Jr (1988) Age and bone mass as predictors of fracture in a prospective study. J Clin Invest 81:1804–1809
Cummings SR, Black DM, Nevitt MC, Browner W, Cauley J, Ensrud K, Genant HK, Palermo L, Scott J, Vogt T (1993) Bone density at various sites for prediction of hip fractures. Lancet 341:72–75
Genant HK, Gluer CC, Faulkner KG, Majumdar S, Harris ST, Engelke K, Hagiwaea S, van Kuijk C (1982) Acronyms in bone densitometry (Letter to the Editor). J Bone Miner Res 7:1239
Price RI, Barnes MP, Gutteridge DH, Baron-Hay M, Prince RL, Retallack RW, Hickling C (1989) Ultradistal and cortical forearm bone density in the assessment of postmenopausal bone loss and nonaxial fracture risk. J Bone Miner Res 4:149–155
Nilas L, Gotfredsen A, Hadberg A, Christiansen C (1988) Age-related bone loss in women evaluated by the single and dual photon technique. Bone Miner 4:95–103
Schlenker RA, Von Seggen WW (1976) The distribution of cortical and trabecular bone mass along the lengths of the radius and ulna and the implications for in vivo bone mass measurements. Calcif Tissue Res 20:41–52
Nilas L, Borg J, Gotfredsen A, Christiansen C (1985) Comparison of single- and dual-photon absorptiometry in postmenopausal bone mineral loss. J Nucl Med 26:1257–1262
Weinstein RS, New KD, Sappinton LJ (1991) Dual-energy x-ray absorptiometry versus single photon absorptiometry of the radius. Calcif Tissue Int 49:313–316
Overton TR, Wheeler GD (1992) Bone mass measurements in the distal forearm using dual-energy x-ray absorptiometry and gamma-ray computed tomography: a longitudinal, in vivo comparative study. J Bone Miner Res 7:375–381
Leboff MS, El-Hajj Fuleihan G, Angell JE, Chung S, Curtis K (1992) Dual-energy x-ray absorptiometry of the forearm: reproducibility and correlation with single-photon absorptiometry. J Bone Miner Res 7:841–846
Nieves JW, Cosman F, Mars C, Lindsay R (1991) Comparative assessment of bone mineral density of the forearm using single photon and dual x-ray absorptiometry. Calcif Tissue Int 51:352–355
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Kelly, T.L., Crane, G. & Baran, D.T. Single X-ray absorptiometry of the forearm: Precision, correlation, and reference data. Calcif Tissue Int 54, 212–218 (1994). https://doi.org/10.1007/BF00301681
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00301681