Abstract
ECG-gated single-photon emission-computed tomography of the intracardiac blood pool is a new technique that has not previously been widely applied. It involves the acqusition of ECG-gated images of the intracardiac blood pools labelled with sodium pertechnetate Tc 99m in 32 projections around the left-anterior hemithorax using a rotating gamma camera. From these images, tomographic sections are reconstructed orthogonal to the long axis of the left ventricle. The heart is therefore imaged three dimensionally, and more extensive information is obtained than in planar radionuclide ventriculography where imaging is usually restricted to only a single projection. Both structure and function can be studied, and the left-ventricular volume and ejection fraction, and wall motion are obtained. Of 50 patients studied, 7 cases are illustrated in order to show normal findings, examples of wall motion that were not shown by planar-contrast and radionuclide ventriculography, examples of the localisation of ventricular hypertrophy, and a comparison between blood-pool and 201TI myocardial tomography.
Similar content being viewed by others
References
Ambrose J (1973) Computerised transverse transaxial scanning (tomography). 2. Clinical application. Br J Radiol 46:1023–1047
Budinger TF, Gullberg GT (1977) Transverse section reconstruction of gamma-ray emitting radionuclides in patients. In: TerPogossian MM, Phelps ME, Brownell GL, Cox JR Jr, Davis DO, Evens RG (eds) Reconstruction tomography in diagnostic radiology and nuclear medicine. University Park Press, Baltimore, pp 318–321
Chaitman BR, Bristow JD, Rahimtoola SH (1973) Left ventricular wall motion assessed by using fixed external reference systems. Circulation 48:1043–1054
Hoffman EJ (1982) 180° compared with 360° sampling in SPECT. J Nucl Med 23:745–747
Hounsfield GN (1973) Computerised transverse axial scanning (tomography). 1. Description of system. Br J Radiol 46:1016–1022
Kuhl DE, Edwards RQ (1963) Image separation radioisotope scanning. Radiology 80:653–661
Maublant J, Bailly P, Mestas D, Cassagnes J, Veyre A, Jallut H, Meyniel G (1982) Gated single photon emission computerized tomography (SPECT) of the cardiac cavities. J Nucl Med 23:P25
Mukai T, Tamaki N, Ishii Y, Minato K, Yamamoto K, Morita R, Torizuka K, Yonekura Y (1982) ECG-gated emission computed tomography of the cardiac blood-pool using rotating gamma camera. J Nucl Med 23:P53
Philippe L, Itti R, Lorgeron JM, Demeyer JF, Raynaud P (1982a) Thick slice emission tomography for quantitative assessment of cardiac function. J Nucl Med 23:P61
Philippe L, Itti R, Tauxe WN (1982b) Tomographic assessment of left ventricular volume. J Nucl Med 23:P61
Tamaki N, Yonekura Y, Muaki T, Fujita T, Nohara R, Kadota K, Kambara H, Kawai C, Torizuka K, Ishii Y (1984) Segmental analysis of stress thallium myocardial emission tomography for localisation of coronary artery disease. Eur J Nucl Med 9:99–105
Tauxe WN, Soussaline A, Todd-Pokropek A, Cao A, Collard P, Richard S, Raynaud C, Itti R (1982) Determination of organ volume by single-photon emission tomography. J Nucl Med 23:984–987
Underwood SR, Walton S, Laming PJ, Ell PJ, Emanuel RW, Swanton RH (1983) Differential sensitivity of Fourier phase and amplitude images in the detection of anterior and inferior left ventricular wall motion. Nucl Med Commun 4:135
Underwood SR, Walton S, Brown NJG, Laming PJ, Ell PJ, Emanuel RW, Swanton RH (1984a) The relationship between phase and heart rate. In: Hoefer R, Bergman H (eds) Radioaktive Isotope in Klinik und Forschung, vol 16. H. Egermann, Vienna, pp 339–345
Underwood SR, Walton S, Laming PJ, Jarritt PH, Ell PJ, Emanuel RW, Swanton RH (1985) Left ventricular volume and ejection fraction determined by gated blood pool emission tomography. Br Heart J 53:216–222
Walton S, Yannikas J, Jarritt PH, Brown NJG, Swanton RH, Ell PJ (1981) Phasic abnormalities of left ventricular emptying in coronary artery disease. Br Heart J 46:245–253
Author information
Authors and Affiliations
Additional information
This work was supported by the Sir Jules Thorn Charitable Trust
Rights and permissions
About this article
Cite this article
Underwood, S.R., Walton, S., Ell, P.J. et al. Gated blood-pool emission tomography: A new technique for the investigation of cardiac structure and function. Eur J Nucl Med 10, 332–337 (1985). https://doi.org/10.1007/BF00251306
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00251306