Skip to main content
Log in

Comparison of simultaneous 99mTc-HMPAO and 111In oxine labelled white cell scans in the assessment of inflammatory bowel disease

  • Original Articles
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Forty-seven patients, 29 with chronic inflammatory bowel disease (1131) and 18 with presumed irritable bowel syndrome, including one with uncomplicated diverticular disease, were studied with simultaneous technetium-99m hexamethylpropylene amine oxime and indium-111 oxine labelled leucocyte scans performed at 1, 3 and 24 h. Twenty-seven patients with IBD had active disease as judged by clinical and laboratory criteria and all of these had positive scans with both agents. No false positive studies were obtained. The 1-h 99mTc-HMPAO WBC scans showed the same distribution to disease as the 3-h 111-In WBC scans, with no difference in intensity (P < 0.92); they showed more extensive disease (P < 0.02) and more intense uptake (P < 0.001) than did the 1-h 111-In scans. The 3-h 99mTc-HMPAO WBC scans showed more extensive disease (P < 0.002), with greater intensity (P < 0.0005), than did the 3-h 111In WBC scans. Physiological bowel activity on 3-h 99mTc-HMPAO WBC scans was present in 12 patients but was faint and did not interfere with assessment of disease extent and activity. It is concluded that in terms of isotope availability, radiation dosimetry and image quality, 99mTc-HMPAO is the agent of choice in detecting active IBD, with localization of disease possible at 1-h after re-injection and optimal resolution and definition of disease extent at 3 h. A negative scan reliably excludes active disease.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Fellows W, Freeman JG, Holmes GKT. Crohn's disease activity in the city of Derby 1951–85. Gut 1990; 31:1262–1265.

    Google Scholar 

  2. Saverymuttu SH, Peters AM, Hodgson HJ, et al. Indium-111 autologous leucocyte scanning; comparison with radiology for imaging the colon in inflammatory bowel disease. Br Med J 1982; 285:255–257.

    Google Scholar 

  3. Saverymuttu SH, Camilleri M, Rees H, et al. Indium-111 granulocyte scanning in the assessment of disease extent and activity in inflammatory bowel disease. Gastroenterology 1986; 90:1121–1128.

    Google Scholar 

  4. Roddie M, Peters AM, Danpure H, et al. Inflammation: imaging with 99mTc-HMPAO labelled leucocytes. Radiology 1988; 166:767–772.

    Google Scholar 

  5. Kennan N, Facey P, Jones J, et al. 99mTc-HMPAO imaging in Crohn's disease of the small bowel (abstract). Br J Radiol 1990; 63:45.

    Google Scholar 

  6. Scholmerich J, Schmidt S, Schumichen C, et al. Scintigraphic assessment of bowel involvement and disease activity in Crohn's disease using Tc-99m HMPAO as a leucocyte label. Gastroenterology 1988; 95:1287–1293.

    Google Scholar 

  7. Mountford PJ, Kettle AG, O'Docherty MJ, et al. Comparison of Tc-99m HMPAO leucocytes with indium-111 oxine leucocytes for localising intra-abdominal sepsis. J Nucl Med 1990; 31:311–315.

    Google Scholar 

  8. Harvey RF, Bradshaw JM. A simple index of Crohn's disease activity. Lancet 1990; 1:514

    Google Scholar 

  9. Solankji KK, Mather SJ, Al Janabi M, et al. A rapid method for the preparation of 99mTc hexametazine-labelled leucocytes. Nucl Med Commun 1988; 9:753–761.

    Google Scholar 

  10. Costa DC, Lui D, Ell PJ. White cells radiolabelled with 111-In and 99mTc — a study of relative sensitivity and in vivo viability. Nucl Med Commun 1988; 9:725–731.

    Google Scholar 

  11. Becker CW, Fischbach W, Weppler M, et al. Radiolabelled granulocytes in inflammatory bowel disease; diagnostic possibilities and clinical indications. Nucl Med Commun 1988; 9:693–701.

    Google Scholar 

  12. Spinelli F, Milella M, Sara R. The usefulness of the one hour 99mTc-HMPAO leucocyte scan in the early diagnosis of acute abdominal sepsis. J Nucl Med 1990; 10:1743.

    Google Scholar 

  13. Shrimpton PC, Wall BF, Jones DG et al. National servey of doses to patients undergoing a selection of routine X-ray examination in English hospitals. NRPB R200.

Download references

Author information

Authors and Affiliations

Authors

Additional information

Correspondence to: R.A. Allan

Rights and permissions

Reprints and permissions

About this article

Cite this article

Allan, R.A., Sladen, G.E., Bassingham, S. et al. Comparison of simultaneous 99mTc-HMPAO and 111In oxine labelled white cell scans in the assessment of inflammatory bowel disease. Eur J Nucl Med 20, 195–200 (1993). https://doi.org/10.1007/BF00169998

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00169998

Key words

Navigation