Skip to main content
Log in

Field-Amplified Sample Injection and Solid-Phase Extraction for Sensitivity Improvement of Electrophoretic Determination of Indole-3-Acetic Acid and Indole-3-Butyric Acid in Food Samples

  • Published:
Food Analytical Methods Aims and scope Submit manuscript

Abstract

A sensitive method has been established by using activated carbon as an adsorbent for extraction of indole-3-acetic acid (IAA) and indole-3-butyric acid (IBA) from bean sprout, tomato, potato, cucumber, and wheat grain prior to field-amplified sample injection-micellar electrokinetic capillary chromatography (FASI-MEKC) detection. Parameters affecting FASI and solid-phase extraction (SPE) were optimized in detail. Under the optimal conditions, the sensitivity of SPE-FASI-MEKC for IAA and IBA was respectively improved by 32.5 and 29.7 times as compared with the direct MEKC. The detection limits were 4.1 for IAA and 5.3 ng mL−1 for IBA with 4.9–5.2% RSD (n = 9, C = 0.03 μg mL−1). The new method has been successfully applied to detect IAA and IBA in bean sprout, tomato, potato, cucumber, and wheat grain with the recoveries of 81.7–110%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

Download references

Funding

This project was financially supported by the Education Committee of Hubei Province (D20132501) and Hubei Key Laboratory of Pollutant Analysis and Reuse Technique (Hubei Normal University) (PA150208).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yiwei Wu.

Ethics declarations

Conflict of Interest

Yang Zheng declares that he has no conflict of interest. Xiaofeng Peng declares that he has no conflict of interest. Yiwei Wu declares that he has no conflict of interest.

Ethical Approval

This article does not contain any studies with human participants or animals performed by any of the authors.

Informed Consent

Not applicable.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zheng, Y., Peng, X. & Wu, Y. Field-Amplified Sample Injection and Solid-Phase Extraction for Sensitivity Improvement of Electrophoretic Determination of Indole-3-Acetic Acid and Indole-3-Butyric Acid in Food Samples. Food Anal. Methods 11, 1155–1162 (2018). https://doi.org/10.1007/s12161-017-1091-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12161-017-1091-z

Keywords

Navigation