Skip to main content
Log in

18F-FDG PET/CT in the diagnosis of prosthetic valve endocarditis

  • Original Paper
  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

Recent studies have shown promising results using 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) in the diagnosis of prosthetic valve endocarditis (PVE). However, previous studies did not include negative controls. The aim of this study was to compare 18F-FDG-uptake around prosthetic aortic valves in patients with and without PVE and to determine the diagnostic performance of 18F-FDG PET/CT in the diagnosis of PVE. 18F-FDG PET/CT examinations in patients with a prosthetic aortic valve performed 2008–2014 were retrieved. Eight patients with a final diagnosis of definite PVE were included in the analysis of the diagnostic performance of 18F-FDG PET/CT. Examinations performed on suspicion of malignancy in patients without PVE (n = 19) were used as negative controls. Visual and semi-quantitative analysis was performed. Maximal standardized uptake value (SUVmax) in the valve area was measured and SUVratio was calculated by dividing valve SUVmax by SUVmax in the descending aorta. The sensitivity was 75 %, specificity 84 %, positive likelihood ratio [LR(+)] 4.8 and negative likelihood ratio [LR(−)] 0.3 on visual analysis. Both SUVmax and SUVratio were significantly higher in PVE patients [5.8 (IQR 3.5–6.5) and 2.4 (IQR 1.7–3.0)] compared to non-PVE patients [3.2 (IQR 2.8–3.8) and 1.5 (IQR 1.3–1.6)] (p < 0.001). ROC-curve analysis of SUVratio yielded an area under the curve of 0.90 (95 % CI 0.74–1.0). 18F-FDG-uptake around non-infected aortic prosthetic valves was low. The level of 18F-FDG-uptake in the prosthetic valve area showed a good diagnostic performance in the diagnosis of PVE.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Habib G, Lancellotti P, Antunes MJ, Bongiorni MG, Casalta JP, Del Zotti F, Dulgheru R, El Khoury G, Erba PA, Iung B, Miro JM, Mulder BJ, Plonska-Gosciniak E, Price S, Roos-Hesselink J, Snygg-Martin U, Thuny F, Tornos Mas P, Vilacosta I, Zamorano JL (2015) 2015 ESC Guidelines for the management of infective endocarditis: the task force for the management of infective endocarditis of the European society of cardiology (ESC) endorsed by: european association for cardio-thoracic surgery (EACTS), the European association of nuclear medicine (EANM). Eur Heart J. doi:10.1093/eurheartj/ehv319

    Google Scholar 

  2. Li JS, Sexton DJ, Mick N, Nettles R, Fowler VG Jr, Ryan T, Bashore T, Corey GR (2000) Proposed modifications to the Duke criteria for the diagnosis of infective endocarditis. Clin Infect Dis 30(4):633–638. doi:10.1086/313753

    Article  CAS  PubMed  Google Scholar 

  3. Hill EE, Herijgers P, Claus P, Vanderschueren S, Peetermans WE, Herregods MC (2007) Abscess in infective endocarditis: the value of transesophageal echocardiography and outcome: a 5-year study. Am Heart J 154(5):923–928. doi:10.1016/j.ahj.2007.06.028

    Article  PubMed  Google Scholar 

  4. Vieira ML, Grinberg M, Pomerantzeff PM, Andrade JL, Mansur AJ (2004) Repeated echocardiographic examinations of patients with suspected infective endocarditis. Heart 90(9):1020–1024. doi:10.1136/hrt.2003.025585

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  5. Bruun NE, Habib G, Thuny F, Sogaard P (2014) Cardiac imaging in infectious endocarditis. Eur Heart J 35(10):624–632. doi:10.1093/eurheartj/eht274

    Article  PubMed  Google Scholar 

  6. Fagman E, Perrotta S, Bech-Hanssen O, Flinck A, Lamm C, Olaison L, Svensson G (2012) ECG-gated computed tomography: a new role for patients with suspected aortic prosthetic valve endocarditis. Eur Radiol 22(11):2407–2414. doi:10.1007/s00330-012-2491-5

    Article  PubMed  Google Scholar 

  7. Habets J, Tanis W, van Herwerden LA, van den Brink RB, Mali WP, de Mol BA, Chamuleau SA, Budde RP (2014) Cardiac computed tomography angiography results in diagnostic and therapeutic change in prosthetic heart valve endocarditis. Int J Cardiovasc Imaging 30(2):377–387. doi:10.1007/s10554-013-0335-2

    Article  PubMed  Google Scholar 

  8. Prendergast BD, Tornos P (2010) Surgery for infective endocarditis: who and when? Circulation 121(9):1141–1152. doi:10.1161/CIRCULATIONAHA.108.773598

    Article  PubMed  Google Scholar 

  9. Jamar F, Buscombe J, Chiti A, Christian PE, Delbeke D, Donohoe KJ, Israel O, Martin-Comin J, Signore A (2013) EANM/SNMMI guideline for 18F-FDG use in inflammation and infection. J Nucl Med 54(4):647–658. doi:10.2967/jnumed.112.112524

    Article  PubMed  Google Scholar 

  10. Saby L, Laas O, Habib G, Cammilleri S, Mancini J, Tessonnier L, Casalta JP, Gouriet F, Riberi A, Avierinos JF, Collart F, Mundler O, Raoult D, Thuny F (2013) Positron emission tomography/computed tomography for diagnosis of prosthetic valve endocarditis: increased valvular 18F-fluorodeoxyglucose uptake as a novel major criterion. J Am Coll Cardiol 61(23):2374–2382. doi:10.1016/j.jacc.2013.01.092

    Article  PubMed  Google Scholar 

  11. Ricciardi A, Sordillo P, Ceccarelli L, Maffongelli G, Calisti G, Di Pietro B, Caracciolo CR, Schillaci O, Pellegrino A, Chiariello L, Andreoni M, Sarmati L (2014) 18-Fluoro-2-deoxyglucose positron emission tomography-computed tomography: an additional tool in the diagnosis of prosthetic valve endocarditis. Int J Infect Dis. doi:10.1016/j.ijid.2014.04.028

    PubMed  Google Scholar 

  12. Rouzet F, Chequer R, Benali K, Lepage L, Ghodbane W, Duval X, Iung B, Vahanian A, Le Guludec D, Hyafil F (2014) Respective performance of 18F-FDG PET and radiolabeled leukocyte scintigraphy for the diagnosis of prosthetic valve endocarditis. J Nucl Med 55(12):1980–1985. doi:10.2967/jnumed.114.141895

    Article  CAS  PubMed  Google Scholar 

  13. Pizzi MN, Roque A, Fernandez-Hidalgo N, Cuellar-Calabria H, Ferreira-Gonzalez I, Gonzalez-Alujas MT, Oristrell G, Gracia-Sanchez L, Gonzalez JJ, Rodriguez-Palomares J, Galinanes M, Maisterra-Santos O, Garcia-Dorado D, Castell-Conesa J, Almirante B, Aguade-Bruix S, Tornos P (2015) Improving the diagnosis of infective endocarditis in prosthetic valves and intracardiac devices with 18F-FDG-PET/CT-angiography: initial results at an infective endocarditis referral center. Circulation. doi:10.1161/circulationaha.115.015316

    Google Scholar 

  14. Tanis W, Scholtens A, Habets J, van den Brink RB, van Herwerden LA, Chamuleau SA, Budde RP (2014) Positron emission tomography/computed tomography for diagnosis of prosthetic valve endocarditis: increased valvular 18F-fluorodeoxyglucose uptake as a novel major criterion. J Am Coll Cardiol 63(2):186–187. doi:10.1016/j.jacc.2013.06.069

    Article  PubMed  Google Scholar 

  15. Habib G, Badano L, Tribouilloy C, Vilacosta I, Zamorano JL, Galderisi M, Voigt JU, Sicari R, Cosyns B, Fox K, Aakhus S (2010) Recommendations for the practice of echocardiography in infective endocarditis. Eur J Echocardiogr 11(2):202–219. doi:10.1093/ejechocard/jeq004

    Article  PubMed  Google Scholar 

  16. Zoghbi WA, Chambers JB, Dumesnil JG, Foster E, Gottdiener JS, Grayburn PA, Khandheria BK, Levine RA, Marx GR, Miller FA, Jr., Nakatani S, Quinones MA, Rakowski H, Rodriguez LL, Swaminathan M, Waggoner AD, Weissman NJ, Zabalgoitia M (2009) Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report From the American society of echocardiography’s guidelines and standards committee and the task force on prosthetic valves. J Am Soc Echocardiogr 22 (9):975–1014; quiz 1082–1014. doi: 10.1016/j.echo.2009.07.013

  17. Walther T, Autschbach R, Falk V, Baryalei M, Scheidt A, Dalichau H, Mohr FW (1996) The stentless Toronto SPV bioprosthesis for aortic valve replacement. Cardiovasc Surg 4(4):536–542

    Article  CAS  PubMed  Google Scholar 

  18. Jaskowiak CJ, Bianco JA, Perlman SB, Fine JP (2005) Influence of reconstruction iterations on 18F-FDG PET/CT standardized uptake values. J Nucl Med 46(3):424–428

    PubMed  Google Scholar 

  19. Adams MC, Turkington TG, Wilson JM, Wong TZ (2010) A systematic review of the factors affecting accuracy of SUV measurements. AJR Am J Roentgenol 195(2):310–320. doi:10.2214/AJR.10.4923

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Erika Fagman.

Ethics declarations

Conflict of interest

None

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Fagman, E., van Essen, M., Fredén Lindqvist, J. et al. 18F-FDG PET/CT in the diagnosis of prosthetic valve endocarditis. Int J Cardiovasc Imaging 32, 679–686 (2016). https://doi.org/10.1007/s10554-015-0814-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-015-0814-8

Keywords

Navigation