Abstract
A programmed algorithm to compute a weighted ensemble average on a set of output signal realizations is presented. Thus programmed, the PDP-8/I can recover output signals, which are due to periodic input signals, from a noisy system. Arbitrarily, large enhancement of signal-to-noise ratio is attainable. The configuration used is a 4K PDP-8/I with AD08-B analog-to-digital converter.
Article PDF
Similar content being viewed by others
Reference
RHYNE, V. T. A comparison of coherent averaging techniques for repetitive biological signals. Medical Research Engineering, August–September 1969.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Scott, D.E., Dzendolet, E. The PDP-8/I as a CAT. Behav. Res. Meth. & Instru. 3, 79–81 (1971). https://doi.org/10.3758/BF03206992
Issue Date: