Skip to main content
Log in

Compensation of the reactive power in the presence of higher voltage harmonics at coke plants

  • Equipment and Power Systems
  • Published:
Coke and Chemistry Aims and scope Submit manuscript

Abstract

The capacitive compensation of reactive power in the presence of harmonic distortion in the supply voltage is considered. Such distortion may be introduced both by factors in the external grid and by factors within the enterprise. That must be taken into account in selecting systems for reducing the effect of higher harmonics on compensating capacitor banks and improving the power quality at coke plants.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. GOST (State Standard) 32144-2013:Electric Energy. Electromagnetic Compatibility of Technical Equipment. Power Quality Limits in the Public Power Supply Systems, 2014.

  2. Dobush, V.S., Korovchenko, P.V., and Shklyarskiy, Ya.E., Analysis of phase difference influence in non-linear load on the power supply calculation, Estestv. Tekh. Nauki, 2013, vol. 6, no. 68, pp. 275–280.

    Google Scholar 

  3. Skamyin, A.N. and Shklyarskiy, Ya.E., Reduction of higher harmonics in the networks of industrial enterprises, Prom. Energ., 2012, no. 8, pp. 44–47.

    Google Scholar 

  4. Bazhin, V.Y. and Titov, O.V., Analysis of the coking process on the basis of heat-flux calorimetry, Coke Chem., 2015, vol. 58, no. 7, pp. 254–258.

    Article  Google Scholar 

  5. Das, B.P., Watson, N.R., and Liu, Y., An investigation into thyristor-based seven-level multi-level current reinjection current source converter, Electr. Power Compon. Syst., 2014, vol. 42, no. 2, pp. 203–214.

    Article  Google Scholar 

  6. Ramos-Carranza, H.A., Medina-Ríos, A., Segundo, J., and Madrigal, M., Suppression of parallel resonance and mitigation of harmonic distortion through shunt active power compensation, Int. J. Electr. Power Energy Syst., 2016, vol. 75, pp. 152–161.

    Article  Google Scholar 

  7. Xia, Z., Shi, L., and Yang, X., Parameters design and control strategy of cascade STATCOM based on LCL filter, Int. J. Control Autom., 2014, vol. 7, no. 1, pp. 307–320.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ya. E. Shklyarskiy.

Additional information

Original Russian Text © Ya.E. Shklyarskiy, A.N. Skamyin, 2016, published in Koks i Khimiya, 2016, No. 4, pp. 44–49.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Shklyarskiy, Y.E., Skamyin, A.N. Compensation of the reactive power in the presence of higher voltage harmonics at coke plants. Coke Chem. 59, 163–168 (2016). https://doi.org/10.3103/S1068364X16040062

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3103/S1068364X16040062

Keywords

Navigation