Background

Estimation of neonate survival is critical to population monitoring and the successful management of white-tailed deer (Odocoileus virginianus) [1,2,3]. Traditionally, researchers opportunistically captured neonates by either systematical searching of fawning habitat or observing maternal female behavior [4,5,6]. Opportunistic capture methods are often efficient and can yield a large number of captured neonates. Vaginal implant transmitters (VIT) were developed to enable the location of birth sites and aid in the timely capture of neonatal ungulates [7]. Using a modified version of existing radio telemetry technology, the VIT utilizes a very-high-frequency (VHF) transmitter equipped with a parturition-indicating motion switch and internal spiral antenna. With the advent of VIT technology, researchers were able to explore new patterns in ungulate reproduction. Researchers could connect individual neonates to their dams, which allowed maternal characteristics (e.g.; age, condition) to be examined as covariates in neonate survival studies [8]. Additionally, neonates could be captured within hours of parturition and enter a survival analysis immediately following birth. Use of opportunistic capture results in a varying age distribution [9], with captured neonates ranging in age from 0 to ≥ 14 days old [10, 11]. More recently, researchers examined changes in movement behavior using fine-scale relocation data from parturient females to identify birth site locations [12, 13], although the transmission and analysis of the data often require a several-day delay before neonates are captures. Varying age distributions can lead to inflated survival rates and a misrepresentation of cause-specific mortality due to missed opportunities to observe early-life mortalities [9, 14]. Use of VITs meant that all individuals entered the survival window at the same age and monitoring began at the earliest possible time.

With traditional VITs, researchers implanted transmitters into gravid females in the winter and then monitored the status of the transmitter via VHF telemetry until parturition in the spring [7]. The transmitter is expelled at the birth site and after a period of inactivity (typically ~ 2–3 h); the motion sensor triggered an event signal (i.e., mortality switch) indicating to the researcher that a parturition event had occurred. The researcher then follows the VHF signal to the location of the parturition site. Original VIT designs had issues with low retention rates (< 50%) in deer and premature expulsion [15, 16]. Furthermore, initial designs required suturing of the vulva to retain transmitters within the vaginal canal [7] increasing trauma and risk of infection during device implantation and expulsion. An improved VIT design added silicone wings, which held the device in the vaginal canal closer to the cervix and eliminated the need for sutures [13]. This improved design also had an external antenna, which improved the ability to monitor the status of VIT while implanted in the female and to locate it after expulsion [15]. Retention rate with the updated design increased up to 75% [15]. Additional updates included adding a temperature and photo-sensor switch [17].

A recent update to traditional VHF VITs pairs the VIT to a GPS collar on the female via ultra-high-frequency (UHF) radio signal communication (radio-linked VIT; hereafter rVIT), eliminating the need for scheduled telemetry monitoring and providing near instantaneous notification of parturition. Our objective was to provide an initial review of the performance and effectiveness of rVIT systems for locating neonatal white-tailed deer. We evaluated the transmitters based on rates of technological failure, retention, the number of neonates located per transmitter, and the rate at which researchers located > 1 neonate at a birth site.

Study area

We conducted our research in Sussex County, Delaware, USA. Sussex County is located on the coastal plain bordered on the north by Kent County, Delaware, on the east by the Atlantic Ocean, and on the south and west by Maryland. Elevation ranged from 0 to 21 m above sea level [18], with little regional variability. Land cover in the study area was 22% upland forest, 22% forested wetland, 15% development, and 41% agriculture; primary crops were corn, soybeans, and wheat [19].

The estimated deer density in Sussex County was 19.4 deer/km2 [20]. Sussex County lacks established populations of natural predators of white-tailed deer (e.g., coyote [Canis latrans], bobcat [Lynx rufus], black bear [Ursus americanus]) [21]. Parturition events during our study occurred between 09 May and 23 June in 2016 and 2017, during which daily temperatures averaged a high of 35 °C and a low of 3 °C [22].

Methods

Animal capture and handling

We deployed 44 (2015–2016: n = 20; 2016–2017: n = 24) rVIT systems (Model M3930U, Advanced Telemetry Systems, Isanti, MN, USA) on adult female white-tailed deer between December and April. We captured deer using rocket nets baited with whole kernel corn [23]. Once captured, we physically restrained and blindfolded each deer before delivering an intramuscular injection of xylazine (0.5 mg/kg) for chemical immobilization. We estimated age using tooth replacement and wear [24] and deployed rVITs in all females ≥ 1.5 years old. Although the accuracy of tooth replacement and wear methodology has been criticised for deer ≥ 2 years old [25], fawns and individuals ≥ 1.5 years old can be differentiated with reasonable certainty [26]. We implanted the rVITs to a depth of 20 cm [6, 15]. Once rVIT implantation was completed, we reversed animals with an intramuscular injection of tolazoline (4 mg/kg), an antagonist for xylazine. We allowed animals to recover and leave the capture area under their own power.

Given the high rate of conceptus (0.94 [SD = 0.02]) [27] in the study area among females ≥ 1.5 years old, we elected to forgo trans-abdominal ultrasound and inserted all females with a transmitter, which is consistent with the previous research [28, 29]. Operator misinterpretation of conceptus presence introduced a greater potential for error in our study area [30] than an assumption of a 100% conception rate, and the animal welfare risks associated with increased handling time [31, 32] outweighed the risk of implanting a transmitter in a non-gravid female. Furthermore, implants do not appear to result in complications to future reproduction when retained past the typical parturition period [33]. The University of Delaware Institutional Animal Care and Use Committee approved all capture and handling procedures (Protocol #1288).

VIT monitoring

The rVIT system is equipped with a second antenna (Fig. 1) used to communicate with a GPS collar via UHF. The GPS collar is able to recognize parturition events from the UHF signal, communicate the information to an Iridium satellite network, which then notifies the user via email. Traditionally, studies using standard VIT technology required manual monitoring of VIT signals (typically every 6–8 h) throughout the fawning season [6, 15, 34]. The rVIT system eliminates the need for intensive manual monitoring. Following deployment, we monitored rVIT daily for any change from the “birth not-yet triggered” designation via an online interface. The rVIT system provides simultaneous monitoring of all deployed devices across the entire study area from a single user interface and nearly instantaneous notification (0–45 min) of a parturition event.

Fig. 1
figure 1

Traditional very-high-frequency (VHF) vaginal implant transmitters (top) and radio-linked transmitter (rVIT; below). Note the secondary black antenna allowing pairing of the rVIT and the GPS collar via ultra-high-frequency (UHF) radio signal. Both transmitters are 7.5 cm in length from the wings to the end of the housing, 1.5-cm diameter, and the wings are 6.5-cm wide. The VHF antenna on both transmitters is 9.5 cm, for a total transmitter length of 17 cm, and the black UHF antenna on the rVIT is 8.5-cm long

Once an event occurred, we received an email notification describing the event, the collar serial number, and the latitude/longitude coordinates of the transmission. In 2016, we received 2 types of event notifications. A “temperature sensor trigger” notification indicated that the rVIT temperature had dropped below 32 °C, and a “break in communication” notification indicated that the rVIT had been expelled and was out of the 1.8-m range for UHF communication or the rVIT had stopped emitting a signal (e.g., battery death). In 2017, we received both of the above notifications, as well as a “light sensor trigger” event when the photosensor detected light, indicating expulsion of the rVIT had begun [17]. We initiated search efforts after receiving the “temperature sensor trigger” event notification. If we discovered the rVIT outside of any apparent birth site, we searched the area until we found a birth site. If we did not locate the neonates in the immediate vicinity of the birth site, we systematically searched the surrounding area until we found 1 or more neonates. We used a thermal imaging camera (Scout III, FLIR Systems, Wilsonville, OR, USA) to aid in both day- and night-time searches [35].

For evaluation purposes, we assigned each rVIT to one of the 3 potential outcomes: successful expulsion at birth site, premature expulsion, or technological failure (either rVIT link failure or GPS collar failure). We assigned the rVIT link failure designation to systems where we continued to receive transmissions from the GPS collar but did not receive information regarding the rVIT status. Additionally, the GPS collar failure designation included GPS collars that never linked with the satellites and never transmitted data of any kind. We recorded the overall performance results during each year and the number of neonates captured for each rVIT that successfully expelled at a birth site.

Results

In 2016, we observed a variety of technological malfunctions and failures. Of the 20 rVIT systems deployed, 12 were expelled at the birth site (60%). In the remaining 8 rVITs, we observed technological failures (n = 3; 15%), a collar failure (n = 1; 5%), and premature expulsions (n = 4; 20%). In 2017, following an adjustment of deployment protocols and design alteration by the manufacturer, we observed none of the rVIT failures or GPS collar failures of the previous season (Table 1). Of the 24 systems deployed, 14 expelled at birth sites (58%) and 8 were expelled prematurely (33%). Two (8%) of the rVIT systems from 2017 never reported a birth event, but hourly spatial data from both females showed movements typical of a parturition event and postnatal care. The collars continued to transmit a “birth not-yet triggered” status until we manually deactivated the rVIT link after the typical parturition period (10 July) to conserve collar battery life. We suspect that these rVIT systems failed to communicate a parturition event, but we cannot confirm that parturition occurred. Both females died from anthropogenic causes the following winter, and rVITs were not present in either individual. We classified these 2 observations as suspected notification failures (Table 1). Among rVITs expelled at birth sites in both years, we did not find evidence to support a difference (t24 = 0.47, P = 0.64) in the mean number of neonates located per VIT between 2016 ( = 1.6, SE = 0.3) and 2017 ( = 1.8, SE = 0.3). The percentage of instances where we located > 1 neonate per birth site was greater in 2017 (79%) than in 2016 (58%).

Table 1 Summary of rVIT results for both 2016 (n = 20) and 2017 (n = 24) neonate capture seasons in Sussex County, Delaware, USA

Discussion

The primary benefit of rVIT systems involved the amount of time invested in monitoring efforts prior to parturition. The rVIT self-monitoring system eliminated the need for intensive hourly monitoring regimes leading up to and during the fawning season. The use of rVITs enables researchers to change the scale and scope of their studies in three critical areas; sample size, spatial distribution of study animals, and personnel requirements. By eliminating the need for manual signal monitoring, studies can increase sample sizes beyond what would typically be possible during a 6–8-h monitoring window. To overcome sample size constraints resulting from excessive monitoring costs, previous studies commonly supplemented sample size by incorporating neonates captured via opportunistic methods [36,37,38]. Reductions in the cost of monitoring would allow sufficient sample sizes of neonates to be captured exclusively utilizing rVIT systems and would eliminate the bias in survival and cause-specific mortality estimates associated with opportunistic capture methods [9, 14]. Additionally, the ability to monitor devices remotely eliminates many spatial limitations in terms of distance between marked animals on the landscape and also reduces the number of personnel required to monitor transmitters.

In nutrient-rich agricultural areas, the number of fetuses/adult female is generally 2.0 [39, 40]. Given the amount of agriculture and high rate of conceptus, we expected similar rates of fecundity in the study area. The mean number of neonates located per VIT expelled at a birth site ranges from a low of 1.3 (14 neonates/11 VITs) [32] and 1.4 (79 neonates/56 VITs) [42] to a high of 2.0 (14 neonates/7 VITs) [43] for traditional VHF VITs, which is similar to the rates we observed with rVITs (Table 2). The rates of locating > 1 neonate using rVITs was slightly greater than studies using traditional VITs (52%) [34], although this statistic is not commonly reported. The increased percentage of capturing > 1 neonate in 2017 relative to 2016 was likely due to the addition of the photo sensor notification, which allowed for more timely notification of parturition events [17, 45] and a reduction in the likelihood and distance that neonates would travel from the birth site before the researcher arrived. While we caution researchers from attempting to locate birth sites immediately following parturition, which may prevent the female from grooming, feeding, and bonding with the neonate [34], near instantaneous notification of parturition events allows researchers to establish more uniform search procedures that likely increase the probability of locating neonates at or near the birth site.

Table 2 Summary of reported performance metrics from recent neonate survival research using traditional vaginal implant transmitters relative to results of this study (bottom row) using radio-linked vaginal implant transmitters (VITs) in Sussex County, Delaware, USA

Manufacturer updates following the first year of deployment, such as clarified deployment protocols, improved hardware configuration, and the addition of a photo sensor, resulted in an apparent reduction in the technological failures during the following year. Rates of premature expulsion, however, were similar between years and comparable to previous research using traditional VITs [3, 8, 33, 43]. Given the similar dimensions and wing design, the lack of improved retention rate was not surprising.

The initial cost of rVIT system (approximately $600 for rVIT, $2500 for compatible GPS collar) is greater than traditional VITs (approximately $250 for VIT, $250 for VHF collar), although most recent studies utilize the more costly GPS collars over VHF collars regardless of the VIT technology used [34, 38]. Longer-term cost savings associated with reductions in personnel and monitoring expenses quickly justify the increased transmitter cost when sample size is large and spatial distribution of the study is wide. We observed no improvement in the number of birth sites successfully located using rVIT systems relative to reported rates from studies using traditional VITs, although rVITs may have improved the probability of locating > 1 neonate.

Conclusion

If researchers elect to forgo tans-abdominal ultrasound in the field, obtaining blood samples during adult female capture would allow researchers to confirm conceptus by testing for pregnancy-specific protein B [46, 47]. Knowledge of conceptus status would have allowed us to more accurately assess the 2 cases suspected notification failures, and potential utilize movement behaviors to identify parturition events [12, 13], although presence of a fetus during capture does not necessarily indicate a parturition event will occur. In the future, manufacturers should focus efforts on modifications that improve transmitter retention, since premature expulsion is often the most limiting factor to sample size of captured neonates.