Background

Water use has been growing at more than the rate twice of population increase in the last century. The world’s six billion people are appropriating 54% of all the accessible freshwater contained in rivers, lakes and underground aquifers (WWAP 2012). The available fresh waters are being polluted by anthropogenic factors and are reducing the availability of potable water (Fard et al. 2012). Water quality is becoming a major problem, as evidenced by frequent outbreaks of water borne diseases in both rural and urban areas of developing countries. Water borne diseases are still a major health burden in many parts of the world and estimated to cause about 842,000 diarrhoea disease deaths per year (WHO 2014). At present, 663 million people do not have access to clean and safe water out of which 37% of those people live in Sub-Saharan Africa (UNICEF/WHO 2015). Safe drinking water is defined as water with microbial, chemical and physical characteristics that meet WHO guidelines (WHO 2015). For instance, the microbial guideline states that coliform bacteria must not be detectable in 100 ml samples of water to be considered as safe and their presence in drinking water indicates the possibility of pathogenic bacteria. Regarding the physicochemical quality of drinking water, the guidelines states that water with turbidity values below 5 NTU can be considered as safe, in these terms of turbidity.

Ethiopia is one among the lowest to have accessible quality water supply in Sub-Saharan Africa (UNICEF/WHO 2015). However, the country has halved the number of people without access to safe water since 1990. Despite the remarkable progress seen in Ethiopia, more than 48 million people do not have access to improved water source and the majority of health facilities in the country lack access to clean water (UNICEF/WHO 2015). Even for those people who have access to clean water, the provision is irregular or insufficient where piped water supply operates sporadically. Therefore, storage tanks are commonly used to ensure that there is sufficient water for short or long term usage. Water storage tanks have their own impact on quality of water if they are not handled in hygienic ways such as using of clean utensils and sealing or covering of the storage tanks. Common problems in storage tanks and reservoirs are the loss of disinfectant residual, bacteria re-growth, poor turnover, and excessive detention time (Duer 2006). There are various reports on the re-growth of bacteria in water stored during a short or long time. For instance, Akuffo et al. (2013) recorded up to 250 cfu/100 ml of FC from water storage tanks found in Ghana. The water stored for 1–9 days showed 67% of increased contamination which could be the reason for increment of coliforms as storage time increased (Brick et al. 2004).

In Ethiopia, the discontinuity of drinking water supply, hinders the distribution of water to people in need. This discontinuity creates a need to use storage tanks. Likewise, in Jimma, irregular provision of piped water is frequently observed and presence of water storage tanks is vital. Small to large sized plastic water storage tanks commonly called ‘Rotto’ are found and used as water storage containers. Water stored in unhygienic manner may be re-contaminated, and can cause water borne diseases. Contamination most often occurs with deteriorated infrastructure; allowing entry of particulate or other non-potable material. Therefore, the main objective of this study was to assess physicochemical and bacteriological qualities of tap water stored in water storage tanks.

Methods

Study area

The study was conducted in Jimma town, which is found in Jimma Zone, Oromia, south-west of Ethiopia (Fig. 1). Geographically, Jimma town is located between 7°40′N latitudes, 36°50′E longitude and an average altitude of about 1780 above sea level. The study area is categorized in the climatic zone locally known as Woina Dega (subtropical zone). It is characterized by warm climate with a mean annual maximum temperature of 30 °C and a mean annual minimum temperature of 14 °C (Alemu et al. 2011). The annual rainfall ranges from 1138 to 1690 mm. Jimma University, one of the leading national universities is found in the town and it educates more than 43,000 students yearly.

Fig. 1
figure 1

Map of the study area

The study was conducted on piped-water supply before entering the storage tanks and after leaving the water storage tanks which are found in Jimma. Nineteen water storage tanks were analyzed but the finding from six of water storage tanks presented in this study as most of the tanks were interconnected and the water is delivered with single pipe line. The tanks are made up of plastic material and commonly called ‘Rotto’. The water storing capacity of the tanks ranged from 2500 to 25,000 L and were filled with tap water.

Water sample collection and transportation

All water samples from storage tanks were collected using clean and sterile polyethylene plastic bottles. The samples were stored in an ice box and transported to the environmental health science and technology laboratory of Jimma University, Ethiopia for analysis. Temperature was directly measured but other parameters were tested within 6 h of collection.

Physicochemical analysis

The collected water samples were taken using a pipette from the middle of the beaker for analysis of physicochemical parameters (pH and turbidity). The turbidity for each of the water samples collected from water storage tanks was measured using a turbidity meter (Oakton T-100). The pH and temperature were measured using multi-parameter probe (HACH). For a pH measurement, the equipment was first standardized with a buffer solution of pH ranging from 4 to 9. All tests were performed in triplicates and the averages are reported herein.

Bacteriological analysis

Water samples collected from the storage tanks were plated aseptically onto MacConkey agar for total coliforms and faecal coliforms following the standard protocols as described by Cheesbrough (2006). Incubation was carried out at 37 °C for 24 h for total coliforms and 44.5 °C for 24 h for faecal coliforms and count was carried out following the standard microbiological procedures by APHA (2005).

Data analysis

The collected data were entered into Excel spreadsheet 2007 and summarized using table, percentages and mean. Additionally, the Pearson correlation coefficient and t test were used to analyze the association between various drinking water parameters and detect significant variations among biological parameters in different water storage tanks to determine the difference between before and after storing water.

Results

Bacteriological test of drinking water quality in storage tanks

All water samples collected from drinking water storage tanks were positive for TC and FC (Table 1). The TC counts ranged from 2.6 to 14.3 whereas, the FC counts ranged from 1.3 to 9.33 cfu/100 ml.

Table 1 Mean bacterial count of water samples stored in storage tanks

Physicochemical analysis

The pH of the storage water from different sources ranged from 7.13 to 7.41 and the recorded temperature of the water samples ranged from 21.3 to 23.1 (Table 2). The turbidity value of water samples was ranged from 2.08 to 2.93.

Table 2 Physicochemical quality of water samples stored in storage tanks

Correlation of collected water sample parameters

The correlation analysis indicated the positive association between various water samples parameters (Table 3). Most importantly, very strong positive relationship was observed between pH and bacterial counts before and after water storage. No association was observed between temperature and turbidity.

Table 3 Correlation coefficients among water quality parameters before and after storage

Comparison of bacteriological contamination of water before and after storage

The comparison between bacteriological contamination of drinking water among samples taken from water tanks before and after storage showed that the bacteriological contamination of water with total coliforms is higher than the contamination with faecal coliforms. The result also revealed that the number of total coliforms increased after storage. However, the difference was statistically insignificance (p = 0.06). In the case of faecal coliforms, statistically significant result (p = 0.02) was observed between the numbers before and after storage.

Sanitary conditions of water storage tanks

Unhygienic way of storing water was exhibited in water storage tanks. Leakage of valve seals was the leading responsible for the reported poor water quality in terms of coliforms. Out of the 19 studied water storage tanks, leakage of valve seal was observed in 13 of the tanks (66.6%) (Fig. 2).

Fig. 2
figure 2

Hygienic conditions of water storage tanks

Discussion

People think that piped water have a high quality, though it can be potentially deteriorated (biological and chemical) in distribution systems (AWWA 2007). Many microbial and chemical constituents of drinking water can potentially cause adverse human health effects (WHO 2006). Water storage tanks and reservoirs are critical component of distribution systems, yet can pose significant challenge for water utilities as they often have a negative impact on water quality. In the present study, total coliforms and faecal coliforms are considered as they are indicators of sanitary quality of water and pathogenic bacteria. The presence of colonies in drinking water before and after storage may show that the water either contaminated during distribution or the treatment process was not sufficient to eliminate microorganisms. This is a problem in developing countries where microbial contamination of protected drinking water is wide spread. The term “protected water” made international estimates to greatly overstate access to safe drinking water and call for enhanced monitoring strategy combining indicators of sanitary protection with measures of water quality (Bain et al. 2014).

For instance, Zaqoot et al. (2016) recorded low to high total coliforms (1–100 cfu/100 ml) from tap water stored in storage tanks found in Palestine. Similarly, drinking water samples collected from different protected sources found in Wondo Genet were positive for total coliforms (Meride and Ayenew 2016). The study analyzed 1–4 cfu/100 ml of total coliforms in the water samples. Total coliforms (10 cfu/100 ml) were analyzed in the water samples used for drinking around Jimma Zone (Abera et al. 2011). The type of water, water treatment efficiency, handling practice, site and type of container could aid to the growth of microbes in treated water (Brick et al. 2004). The presence of total coliforms in each water sample collected from protected sources and storage tanks deviated from maximum permissible limits of the WHO. Hence, regular inspection is vital for a provision of microbially free drinking water to communities. According to WHO drinking water guidelines, total coliforms should not be detectable in any water intended for drinking (WHO 2006). Storage tank material and size has also a significance effect on the quality of stored water (Cynthia and Schafer 2012). According to one study, water stored in stainless steel tanks was more contaminated than plastic tanks (Aish 2013). Regarding the size, water stored in the large water storage tanks can be contaminated with total coliforms due to the longer storage times, which may potentially increase the risk of contamination and allow chlorine to volatilize (Graham and VanDerslice 2007).

All of the water samples in the current study were positive for faecal coliforms (9.33 cfu/100 ml). Similar to our findings, significantly high counts (up to 250 cfu/100 ml) of faecal coliforms were analyzed in water samples collected from storage tanks found in Ghana (Akuffo et al. 2013). High counts of faecal coliforms (up to 100 cfu/100 ml) were also recorded in household water storage containers in Bahir Dar (Tabor et al. 2011). On the other hand, water samples collected from protected sources were negative for faecal coliforms (Meride and Ayenew 2016). The presence of faecal coliforms in drinking water may affect human health in many ways and it is an indication of the presence of pathogenic bacteria (Mintz et al. 1995). This type of water is not qualified for drinking as 0 cfu/100 ml is the recommended guideline. Several factors could be responsible for the presence of faecal coliforms in water storage tanks. For instance, storage tanks cleaning frequency and presence of human or animal faeces can be main driving factors (Cynthia and Schafer 2012). In addition, some of the storage tanks were not covered properly and soil particles and bird faeces could get into the containers that enhance the growth of faecal coliforms. Thus, keeping the water storage tanks clean could improve the microbiological quality of stored water and reduce diarrhoeal and other waterborne diseases in communities (Thompson et al. 2003).

Regarding turbidity of stored water, low turbidity value (2.93 NTU) was recorded from stored water samples. Similarly, low turbidity value (0.98 NTU) was analyzed in water samples collected from Wondo Genet (Meride and Ayenew 2016) and Jimma Zone (Yasin et al. 2015). In all of the findings, the turbidity value falls within the WHO recommended drinking water guideline (≤5 NTU) which might indicate the coagulant doses used in water treatment was efficient to remove suspendered particles found in raw water.

Concerning pH of water samples, the recorded values ranged from 7.13 to 7.41 where, the value falls within the WHO maximum permissible limits (6.5–8.5). Similar to our findings, Sule et al. (2011) and Yasin et al. (2015) recorded pH of water samples in the range of 6.53–7.45 and 7.4–8.14 respectively. Basic pH was analyzed in water storage samples found in Jordan which is reported to be increased upon storage (Ziadat 2005).

Temperature affects the rate of chemical reactions in the water body (Olajire and Imeokparia 2001) and it plays an important role in the survival of microorganisms (Akuffo et al. 2013). The highest recorded temperature in water storage tanks was 23.1 °C which exceeds the WHO permissible limit of drinking water guidelines (15 °C). This high temperature after storage increased the number of faecal coliforms in storage tanks. It was also reported in one study as high temperature favored the re-growth of bacteria (Muyima and Ngcakani 1998). Storage tank material and color can affect water temperatures in the tanks and placing the tank in a shaded location can reduce temperature meanwhile microbial contamination (Cynthia and Schafer 2012).

Conclusions

The study revealed that pH, temperature and turbidity of stored tap water in all storage tanks were within the WHO maximum permissible limit of drinking water. However, bacterial loads of total coliforms and faecal coliforms were detected in water samples analyzed before and after storage where increased numbers of coliforms were observed after storing the water. The positive results related to total coliforms and faecal might be due to both leakage and contamination in the distribution system or inadequate treatment. Thus, detail risk assessment should be conducted from treatment to distribution including storage and safe handling of water at the point of use in order to provide complete intervention strategies in tackling waterborne diseases.