Background

The transport of veterinary drugs in vehicles must comply with the general standards for drug storage in veterinary dispensaries. Although many veterinary vehicles are equipped with active heating and/or cooling devices (active systems [1]) assuring recommended drug storage conditions, simple insulated transport boxes (passive systems [1]) are also often used in veterinary vehicles [2] as well as in emergency medical service (EMS) vehicles [3]. Such boxes are especially needed for the time when the engine is in non-operating state and the air conditioning of the vehicles is not working (parking time, during consultancy). However, such “simple” transport boxes must assure the maintenance of the appropriate storage temperatures of the drugs kept in them. The thermal properties of the transport boxes, which are exposed to the thermal conditions inside the vehicles, are major factors controlling the retention time for which the recommended storage temperatures can be assured.

The quality of medicines can be negatively affected when subjected to inadequate storage temperatures; thermal degradation and the loss of potency of drugs have been reported following the exceedance of certain temperature thresholds [4,5,6]. Küppers et al. [7] recommended that temperature-sensitive drugs should be replaced after any temperature stress beyond the limits given by the manufacturers (e.g., 25 °C) and that the drugs should be replaced at least once per year. The inactivation process is described by the Arrhenius equation: the higher the temperature, the higher the degradation of active substances [5, 8,9,10]. The recommendations distinguish in general between cool (controlled room temperature) and cold storage conditions defined by the ranges 2 °C to 25 °C and 2 °C to 8 °C, respectively [11, 12].

Beside bags [13], although boxes are used to transport and store temperature-sensitive drugs in veterinary vehicles [2, 3, 14], it often remains unclear whether they are appropriate for this purpose. However, to the knowledge of the authors, no systematic investigations on the suitability or practicability of passive storage boxes for drug transport in vehicles have been published so far. Both exceedance of the upper temperature limit and a shortfall of the temperature to below the lower limit (e.g., freezing) must be considered. The discrepancy between the thermal needs and requirements to store drugs and the realities was shown by Haberleitner et al. [2] and Ondrak et al. [14] for veterinary vehicles.

The dynamic behaviour of the inside temperature of the box depends on two main features. (1) The heat flow rate through the walls of the box depends of the temperature difference between inside and outside temperature, the insulation of the box (wall thickness and thermal conductivity), and the area of the box walls. (2) The heat content depends on the mass and the thermal capacity of the filling. The lower the heat flow rate (1) and the higher the heat capacity of the box (2), the slower the change of the inside temperature.

In this study, the thermal performance of typical transport boxes were specifically investigated under laboratory conditions to reveal the impact of box size, insulation material, liquid vs. dry filling products, filling degree and other parameters. For practical use, a recipe is presented to measure the thermal properties of a transport box and the related retention time for which the recommended storage temperatures can be assured. With this simple model it can be assessed whether a certain transport box is appropriate to carry veterinary drugs without exceeding a certain threshold temperature. The objective of this paper is to contribute to the quality assurance of veterinary drug storage especially in vehicles.

Methods

Six insulated boxes considered typical for drug storage use in veterinary vehicles were investigated under laboratory conditions.

Transport boxes

The transport boxes differed in the type of insulation material, volume, surface area, wall thickness, and colour (Table 1). With the exception of one box (A), which employed a different insulation technique (vacuum plates), the insulation material was expanded polystyrene with a heat conductivity of λ = 0.028 W K−1 m−1, whereas for a vacuum insulated plate, a value of λ = 0.005 W K−1 m−1 was assumed [15]. A vacuum insulated plate consists of an outer layer of expanded polypropylene foam (EPP) with openings for a vacuum insulated panel which is a form of thermal insulation consisting of a gas-tight enclosure surrounding a rigid core, from which the air has been evacuated [15].

Table 1 Properties of the studied transport boxes

Figure 1 shows two typical transport boxes used in the experiments.

Fig. 1
figure 1

Typical drug transportation boxes. The insulation of box a (left) consists of vacuum plates, and box b (right) is insulated only with polystyrene (EPS). The length of the scale is 33 cm

Measurements

To determine the thermal properties of the boxes, the time courses of the inner temperature of water-filled 100 mL bottles, which simulate injection vials, at defined positions in the box were measured in a heating (45 °C) or cooling chamber (−20 °C) to provide a constant ambient temperature. The contact area of the box to the wall of the climate chamber was minimised to prevent heat exchange due to conduction, by the use of point bearings.

The temperature was measured at positions P1 to P6 as depicted in Fig. 2. Measurements were performed using a calibrated Fluke Hydra 2620A with 7 channels in 15 s intervals, with channel 7 recording the ambient temperature.

Fig. 2
figure 2

Measurement points inside a transport box. Points P 1 to P 6 denote the 100 mL water-filled bottles (simulating injection vials) in which the temperature sensors were placed

Determination of the thermal properties of the boxes

The time course of the temperature difference T B  = Θ B - Θ A between the inside temperature Θ B (water bottle) and the ambient temperature Θ A of the heating chamber (Θ A  = 45 °C) or cooling chamber (Θ A  = −20 °C) is given by the Newton’s law of cooling T B  = T B , 0 exp(−γ t) with the temperature difference T B,0 for t = 0 [16]. The thermal constant γ is given by γ = A U m /c and specifies the thermal properties of the transport box. This factor was used to characterise the box and depends on its geometry, the overall coefficient of heat transmission U m (U-value) and the entire heat capacity of its content c (transported drugs). The weighted mean of the overall coefficient of heat transmission U m was calculated with \( {U}_m=\sum_{i=1}^n{A}_i\;{U}_i/\sum_{i=1}^n{A}_i \), where U i is the coefficient of heat transmission of each box wall, and A i is the corresponding wall surface area. The coefficient of heat transmission of a box wall U i is given by \( {U}_i=1/\left(\raisebox{1ex}{$1$}\!\left/ \!\raisebox{-1ex}{${\alpha}_i$}\right.+\sum_{j=0}^n\frac{d_j}{\lambda_j}+\raisebox{1ex}{$1$}\!\left/ \!\raisebox{-1ex}{${\alpha}_o$}\right.\right) \), where α i (α o ) are the coefficients of heat transfer between the air inside (outside) the box and the adjacent surface. The thickness of a material layer is given by d j, and its thermal conductivity by λ j . Since there is almost no forced convection inside the box and in the heating or cooling chamber, the value of α i and α o can be assumed to be α i  = α o  = 3 W m−2 K−1 [17]. The content’s heat capacity is c =  ∑ m i c i depending on the mass of the drugs m i and their heat capacity c i .

Following the determination of the time course of the temperature difference T B during a cooling or heating process, the thermal constant γ was determined by a regression analysis. The temperature was measured at the positions depicted in Fig. 2, and the thermal constant γ i was determined for each of these positions i. The maximum value of the thermal constant was selected for further analysis to reflect a worst-case scenario.

The value of γ was also calculated using the mechanical and thermal properties given in Table 2. For the calculation of the entire heat capacity of the content (stored drugs) of the boxes, two different types of drugs were distinguished: liquid drugs, which show a high specific heat capacity close to that of water, and dry drugs (e.g., powder, tablets). For dry drugs, the specific heat capacity was estimated to be c d  = 1100 kJ kg−1 K−1; for liquid drugs (independently if the drugs are hydrophilic or lipophilic), it was estimated to be c l  = 4000 kJ kg−1 K−1. To increase the heat capacity of the entire box, resulting in a lower thermal constant γ, additional water bottles with a volume of 1000 mL were added.

Table 2 Mechanical and thermal properties of the materials of the insulated boxes and the drugs inside [15,16,17]

The total heat capacity of a box’s content was calculated as c = m d c d  + m l c l  + m w c w where m d and m l denote the mass of dry and liquid drugs (simulated by 100 mL bottles) respectively, and m w the mass of additional 1000 mL water bottles. The corresponding specific heat capacities are shown in Table 2.

The filling degree F was defined as F = c/c maxwith the maximum heat capacity of a boxc max = V i ρ w c w . This assumes that the box’s volume V i is filled entirely with water (water density ρ w  = 1000 kg m−3, and specific heat capacity of water c w  = 4.18 kJ kg−1 K−1). The heat capacity of the air inside a box was neglected. For the measurements inside the climate chamber, the 100 mL bottles as well as the additional 1000 mL water bottles were preconditioned.

Model calculations

Two boxes were modelled (Table 3): box X with a volume of 27 dm3 (inner dimension 3 × 3 × 3 dm3), and box Y with a volume of 54 dm3 (inside dimension 6 × 3 × 3 dm3). The wall thickness is 5 cm, which results in an outside surface area of 0.96 m2 and 1.44 m2, respectively. The coefficient of heat transmission was calculated for expanded polystyrene (EPS) with U m  = 0.408 W m −2 K−1.

Table 3 Parameters for the model calculation for the two transport boxes X and Y

For the first calculation, the two boxes, X and Y, were filled only with three 100 mL bottles (as used for injectables), and in the second calculation, the remaining volume was filled with 1000 mL water bottles, resulting in a total of 24 to 49 bottles for boxes X and Y respectively. The mass of a full 100 mL bottle totals approximately 190 g. This yielded a heat capacity of 2.28 kJ K−1 for the two boxes filled only with drugs and 102.6 kJ K−1 for box X and 207.1 kJ K−1 for box Y when filled with additional 1000 mL water bottles (Table 3).

Results

Measurements

The measurements in the heating (Θ A  = 45 °C) and cooling chamber (Θ A  = −20 °C) were used to determine the thermal constant γ meas which was then compared to corresponding calculated values γ calc (Table 4). The calculations were carried out with the mechanical and thermal properties (Table 2) of the transport boxes. A comparison of measured and calculated γ values by a regression analyses showed a high agreement with a coefficient of determination of r 2 = 0.843, which is significant at the 0.001 level. The filling degree varied between 4.5% and 17.9%. A mean relative deviation of 22% between γ meas and γ calc was found which we attribute to geometric factors (e.g., thermal bridges due to corners, edges and the cover plate). These are not accounted for the chosen model of the coefficient of heat transmission which assumes a plane wall.

Table 4 Comparison of the measured γ meas and the calculated γ calc thermal constant for the six transport boxes and various relative heat capacities, measured in the heating (30 °C) and/or cooling (−10 °C) chamber

Model calculations

Model calculations were performed to demonstrate the impact of box size and their degree of filling on thermal performance for the two boxes X and Y (Table 3).

These calculations were performed for two different environmental conditions: Summer with an ambient temperature of Θ A  = 30 °C and winter with Θ A  = −10 °C. The retention time, defined as the time period during which the storage requirements are fulfilled, was then calculated for the two boxes under the assumption that the box content was thermally preconditioned. For summer calculations it was assumed to have an initial temperature of 2 °C, equal to the lower threshold of cold and cool storage conditions. For winter the corresponding upper thresholds where chosen yielding initial temperatures of 8 °C and 25 °C respectively. The resulting time courses of the drug’s temperatures are plotted in Fig. 3, for a (A) summer scenario and (B) winter scenario.

Fig. 3
figure 3

Model calculation of the time course of the inside temperature Θ B of the two virtual boxes X and Y depending on the size and the filling degree (heat capacity) of the boxes. The chosen parameters represent a summer (a) and a winter scenario (b) for drugs that must be stored either in a cool (2 °C ≤ Θ B  ≤ 25 °C) or cold environment (2 °C ≤ Θ B  ≤ 8 °C). For the summer scenario, the environmental temperature was Θ A  = 30 °C and the initial temperature Θ B  = 2 °C at t = 0 h. For the winter scenario, the environmental temperature was Θ A  = −10 °C, and the initial temperature (t = 0 h), depending on the storage conditions (cool or cold), was Θ B  = 25 °C and Θ B  = 8 °C, respectively

Retention time calculation and various filling degrees for the two boxes are summarised in Table 5. Values below 12 h were marked in bold to show possible drug storage problems during a working day. These calculations show the high impact of the filling degree on retention time, especially for cold storage conditions (2 °C and 8 °C).

Table 5 Retention time (h) of the inside temperature in the recommended temperature range (cool storage conditions 2 °C – 25 °C and cold storage conditions 2 °C – 8 °C) in the insulated boxes X and Y for thermal summer and winter conditions with an ambient temperature of Θ A  = 30 °C and Θ A  = 30 °C, respectively

Calculations for boxes X and Y also demonstrate the influence of a box’s size. The ratio of surface area (responsible for the heat exchange between box and environment) to volume decreases with box size. For the same degree of filling F, the retention time is greater for the larger box, Y, as compared to the smaller box, X (Table 5).

Due to the fact that Table 5 represents model calculations we added high filling degrees to show the importance of this parameter for the retention time, even if these cannot be reached in reality. This demonstrates that the filling degree F should be as big as possible to maximise the retention time of a transport box.

Discussion

The proper transport of temperature-sensitive drugs in vehicles is a widespread and notorious problem [18,19,20,21]. For veterinary vehicles a one year field study was published recently by Haberleitner et al. [2] showing that the drugs are frequently exposed to temperatures not compliant with recommended storage conditions. In many vehicles, drugs are stored in boxes without an active cooling or heating supply. Field measurements showed transport temperatures for emergency medical technician (EMS) vehicles far outside of the recommended temperature range, as summarised by Brown et al. [20]. For summer conditions, maximum inner temperatures up to 60 °C were determined, and for wintertime, minimum temperatures significantly below the freezing point [18, 21]. It became evident that either active heating or cooling systems should be used [18, 22] or other efforts made to maintain the recommended temperatures when passive storage systems are used. However, to the knowledge of the authors, no systematic investigations on the suitability or practicability of passive storage boxes for drug transport in vehicles have been published so far.

Storage temperatures outside the recommended range can affect the quality of drugs [6]. Exceedance of the upper limit of the recommended temperature range may cause a loss of drug quality due to degradation processes. The inactivation process is described by the Arrhenius equation, the higher the temperature the higher the degradation of active substances using the mean kinetic temperature [5, 8,9,10]. The mandatory shelf life of a temperature-sensitive drug allows for a degradation of active substances of less than 5% during correct storage [7, 9, 23]. For a typical drug, an increase in the mean kinetic temperature of 5 °C will decrease the drug’s shelf life by a factor of two [21]. For the US the storage standards of the US Pharmacopeial Convention are summarised by Brown and Campagna [24].

The lower limit of 2 °C for the storage temperature was selected in this study to avoid freezing the drugs, even though the freezing point is an individual constant of each drug and may differ over a wide range [7]. In particular, injection preparations and vaccines are sensitive to freezing and lose quality and efficacy after thawing. Because “frozen” and “not frozen” distinguish between “(potentially) usable” and “not usable” [7, 12], we selected this limit of 2 °C for pragmatic reasons.

To investigate the practicability of insulated boxes for storing drugs in vehicles, we measured the retention time for winter conditions and summer conditions with an experimental ambient temperature of −10 °C and 30 °C, respectively. The measuring protocol of the World Health Organisation [25] for vaccines suggested the ambient temperatures of −5 °C and 43 °C, respectively. The filling degree of the transport boxes, which describes the heat capacity load, was defined in a similar way as proposed by the German [26] and French [27] standards. The measuring points inside the boxes were selected according to the World Health Organisation [25], and the most adverse measuring point was selected for the calculation [28].

The results obtained from the experiments were compared with the values of the thermal constant γ obtained from the model calculation (Table 4). The high coefficient of determination r 2 showed that the selected exponential model corresponds well with the measured time course data for the inner temperature of the box and demonstrates that the thermal constant of practically any transport box can analogously be determined. Thus, the time course and the retention time of any box can be predicted by its geometry, the thermal properties, and the heat capacity of the box as determined by the drugs and the additional water bottles.

Model calculations were performed for two boxes that differ significantly in size and volume to show the influence of these parameters. The time course of the inner temperature of the two boxes differs only slightly (by the constant filling degree of the volume) because the dominant factor is the entire heat capacity of a box. By adding 1000 mL water bottles, the filling degree F can be increased up to 90%, and the retention time can be increased by a factor of approximately 45 and 80 for box X and box Y, respectively. This shows the dominant influence of the filling degree on the retention time [25,26,27]. Insulated transport boxes cannot be considered appropriate to store drugs over a period of more than 12 h (Table 5). This means that after a “working day”, the content of the transport boxes must be stored under appropriate conditions (e.g., transfer into a refrigerator) and thermally preconditioned according to the recommended temperatures before it is transferred back into the box for the next tour. A Haberleitner, G Schauberger, J Horak and I Schmerold [2] were able to show that a proper management of the storage of drugs by using solely styrofoam transport boxes can guarantee the requirements to the thermal storage conditions.

The ambient temperature of the transport boxes is the inside temperature of the vehicles being itself predominantly subjected to the outdoor temperature and the radiation balance if no additional heating and cooling (air-conditioning) is in operation. As long as the incoming solar radiation and the outgoing long-wave radiation is nearly balanced, the indoor temperature of the vehicles is close to the ambient temperature (e.g., during an overcast sky, under a car port, or inside a garage).

If the radiation balance is dominated by the incoming solar radiation, the temperature inside the car stabilises within a range between 20 and 35 K above the outside temperature [29,30,31,32,33,34,35,36]. Marty et al. [37] found a temperature difference even close to 60 K. As a rough estimation, they assessed the inside temperature due to solar radiation could reach 30 °C for winter time, 60 °C for spring and autumn and up to 90 °C during summer time. The harsh environment inside parked vehicles can cause heat stroke as a life-threatening syndrome observed in human and animals [38, 39] which is documented in the US, by 37 lethal heat stokes by children per year (1998–2015) [33, 40].

Grundstein et al. [31] developed simple models to calculate the inside steady state temperature of the cabin as a function of the outside air temperature, the irradiance of the solar radiation, and the cloud cover. The dynamic behaviour of the temperature increase after parking a vehicle in the sun was also measured by several authors [29, 30, 32,33,34, 36]. A dynamic model for the cabin temperature, which is driven by outside air temperature, solar radiation and wind velocity was presented recently [41]. In most cases, a value close to the maximum temperature is achieved 20 min after stopping the ventilation. The most effective measure to reduce the inside temperature is to increase the ventilation by partly opened windows [32, 34,35,36]. The protection of the windows by a cover to reduce the incoming solar radiation was investigated by Jascha and Keck [36] (paper fabrics and tin foil) and Devonshire and Sayer [42] using infrared reflecting foils. They found a reduction up to 11 K [36] and a higher score of thermal comfort [42], compared to the unprotected windows. Veterinary vehicles should, therefore, always be parked during daytime (solar radiation) in the shade. The direct exposure of the transport box to solar radiation through car windows should be strictly avoided during summer conditions. The additional heat flow rate could reach up to 1000 W/m2. This additional heat load would reduce the retention time of a transport box drastically. Therefore the box should be stored also inside the cabin in the shade.

The use of passive boxes for drug transportation should only be a temporary substitute for air conditioning of the cabin to avoid heating as well as freezing. Estimation and knowledge of the thermal properties of the boxes used is a crucial factor for appropriate drug transport in vehicles and an important contribution to quality assurance in veterinary practice.

Conclusion

Observing the physical rules governing the thermal performance of passive boxes, the following principles for drug transportation in vehicles can be recommended:

  • Before transfer into boxes, the drugs should always be thermally preconditioned (i) at the upper limit of the recommended temperature range for ambient temperatures below the recommended temperature (“winter”) or (ii) at the lower limit for ambient conditions above the recommended temperature (“summer”). The most critical storage condition is the range between 2 °C and 8 °C.

  • Increase the filling degree of the box as much as possible by thermally preconditioned water bottles or re-usable thermal packs to increase the heat capacity of the transport box. Do not deep-freeze the bottles or packs below 0 °C to avoid drug freezing due to contact. This recommendation applies also to active devices (e.g., refrigerators).

  • Open the lid of the boxes only to uncase needed drugs. Avoid air exchange especially due to wind effects and due to the thermal rise of the warmer air from inside the boxes during cold outside conditions.

  • The bigger the box and the higher the filling degree, the longer the retention time of the transport box.

  • Wherever possible, place the drug box at a cool site. The vehicle should always be parked in the shade or, if possible, inside a well ventilated car port. The transport box should not be exposed to direct solar radiation.

  • The monitoring of the inside temperature of the transport boxes is recommended using remote temperature sensors and/or temperature data loggers to avoid and/or detect violation of recommended storage temperatures.