Background

Vibrio parahaemolyticus, a curved, Gram-negative bacterium that inhabits estuarine and marine environments, is a major cause of foodborne illness worldwide and is one of the leading causes of foodborne illness in South China [1, 2]. It was first identified in Japan during an outbreak in the 1950s, which caused 272 illnesses. V. parahaemolyticus infections are mainly associated with the consumption of contaminated raw or undercooked seafood and may lead to acute gastroenteritis, wound infection and septicemia [3]. Virulence factors associated with the V. parahaemolyticus pathogen include thermostable direct haemolysin (TDH), TDH-related haemolysin (TRH) and the two type III secretion systems [4] T3SS1 [5] and T3SS2. TDH and TRH may have hemolytic and cytotoxicity activity in the host cell [6, 7]. T3SS1 is found in all V. parahaemolyticus strains, whereas T3SS2 is found in clinical strains and is associated with pandemic strains.

V. parahaemolyticus may respond to environmental changes and human immune responses by the serovar alteration of its somatic (O) and capsular (K) antigen-encoding genes. This can occur via mutation or horizontal gene transfer. The O- and K antigen-encoding loci are adjacent to each other, and therefore the O- and K-antigens may be simultaneously mutated through a single recombination event [8]. Until now, 13 O serogroups and 71 K serotypes have been identified based on the antigenic properties of their O and K antigens [9,10,11]. The O3:K6 serotype is mainly associated with pandemics, however the serotypes O4:K68, O1:K25 and O1:KUT, which are regarded as serovariants of O3:K6, have also been associated with worldwide outbreaks. For instance, O3:K6 and O1:KUT were the main serotypes associated with the 2008–2014 outbreaks in South China. The number of infections caused by the O4:K8 serotype have been increasing in recent years [12]. The O4:K8 virulence factors are the same as those of the O3:K6 pandemic clones, but are genetically distinct from those of the O3:K6, O1:KUT and other internationals strains [13].

Thiosulfate-citrate-bile salts-sucrose (TCBS) is an agar that is used to isolate and identify Vibrios species, including V. parahaemolyticus. Typically, colonies of V. parahaemolyticus appear opaque, round, 2–3 mm in diameter and green or bluish in color [14]. Molecular methods may also be used to identify this species. For example, a polymerase chain reaction (PCR) method that targets the toxR gene can identify V. parahaemolyticus strains at the species level [15]. Multiplex PCR methods that amplify the tdh, trh and tlh genes can detect all strains of V. parahaemolyticus [16]. Real-time PCR and loop mediated isothermal amplification (LAMP) [17] have also been used for the identification of V. parahaemolyticus. Finally, MALDI-TOF MS has been used to identify V. parahaemolyticus in clinical diagnosis [18].

Many molecular typing methods have been implemented in V. parahaemolyticus subtyping. The principal methods are pulsed-field gel electrophoresis (PFGE) [19], which can provide genetic diversity not shown in group specific PCR (GS-PCR), and multilocus sequence typing (MLST) [20], which is a typing method based on seven housekeeping genes. Subtyping based on protein profiles, such as MALDI-TOF MS, has also been used to differentiate environment strains [21].

MALDI-TOF MS is a useful tool in routine clinical diagnosis, because it has the ability to rapidly identify bacterial strains with high accuracy. Recently, several research groups have applied MALDI-TOF MS to the serotyping of Salmonella enterica subsp. Enterica [22], Vibrio cholerae [23] and Escherichia coli [24]. In addition, Kang et al. attempted to subtype Salmonella enterica serovar Typhimurium using MALDI-TOF MS [25] but failure. However, there have been few reports on the application of MALDI-TOF MS to the serotyping of V. parahaemolyticus. In this study, we evaluated the ability of MALDI-TOF MS to screen 23 serotypes from a collection of 146 strains of V. parahaemolyticus isolated in the Zhejiang province of China.

Results

Identification of V. parahaemolyticus by toxR-targeted PCR and MALDI-TOF MS

All 146 strains (Table 1) in this study were toxR+ and identified at the species level. For MALDI-TOF MS identification, the spectra of all strains were transferred into BioTyper 4.0 software and compared with the reference database supplied by the manufacturer. All strains were identified at the species level (data not shown).

Table 1 Vibrio parahaemolyticus strains used in this study

A total of 35 randomly selected strains, representing five main pandemic serotypes, were used to establish a serotype-specific reference database. The spectral quality of each strain was evaluated in terms of the presence and intensity of various peaks using Flex analysis software. Low-quality spectra were replaced with spectra obtained from the fresh spotting of the same protein extract. Comparisons were also performed between the original commercial database and the expanded database that contained our in-house entries. All strains that were not used in database construction received higher scores from the expanded database containing in-house entries than from the manufacturer’s reference database (Table 2).

Table 2 Comparison of identification by commercial database and expanded database after introduction our in-house entries

Phyloproteomic analysis of 23 serotypes

The results of a cluster analysis of 146 strains of 23 serotypes are shown in Additional file 1: Figure S1. The strains were separated into two clusters with a mixed distribution of serotypes. For serotype O3:K6, 62 out of 63 strains were present in Cluster I, while its pandemic serovariants, such as O4:K68 and O1:KUT, were present in both clusters. Two isolates of O1:K25 were present in Cluster I. For serotype O4:K8, 32 out of 36 strains were present in Cluster II, in addition to 14 other strains of the same group. All isolates of O8:K41 were present in the same group as O4:K8. Some rare serotypes, such as O1:K36, were present in both clusters.

Phyloproteomic analysis of O4:K8, O3:K6 and its three main serovariants O4:K68, O1:K25 and O1:KUT

Figure 1 shows the proteomic cluster analysis of 110 strains belonging to five serotypes (O4:K8, O3:K6, O4:K68, O1:K25 and O1:KUT). All isolates of O3:K6 and its serovariants O4:K68 and O1:K25 were present in Cluster I. However, two out of five strains of O1:KUT were separated into Cluster II. For serotype O4:K8, four out of 36 strains were clustered into the same group as O3:K6, and the remaining 32 strains were present in Cluster II.

Fig. 1
figure 1

MALDI-TOF MS-based dendrogram of 110 strains belonging to O3:K6, O4:K8, O4:K68, O1:K25 and O1: KUT

Principal component analysis (PCA) was used to confirm the difference between O4:K8 and the four other serotypes (Additional file 2: Figure S2). Two distinct clusters indicate that there is no obvious correlation between the O4:K8 strains, the O3:K6 strains and the three other pandemic serotypes. These results were also confirmed by composite correlation index (CCI) analysis. A CCI value of 1 represents the highest possible correlation, while a value of 0 represents no correlation. A CCI matrix of representative mass spectra was obtained from all 110 strains belonging to five pandemic serotypes (Additional file 3: Figure S3). A simplified matrix was also obtained using fewer strains and this matrix depicts the differences between the groups clearly (Fig. 2). Most spectra belonging to the O4:K8 serotype were dissimilar to the spectra belonging to O3:K6 and the three other pandemic serotypes; these were denoted as “cold” (green to dark blue). The low CCI values that result from the comparison of O4:K8 with O3:K6, O4:K68, O1:K25 and O:KUT indicate that the discrimination of O4:K8 using spectral fingerprinting is possible.

Fig. 2
figure 2

Composite Correlation Index (CCI) matrix of 35 strains (20 of O3:K6, ten of O4:K8, two of O1: KUT, two of O4:K68 and one of O1:K25) as calculated using Biotyper RTC software. The CCI values were extracted and the displayed image was redrawn using the conditional formatting option in MS Excel. A CCI value approaching 1 indicates congruence among the measured spectra sets and a CCI value of 0 represents completely different spectra

Potential peaks contributing to the differentiation of O4:K8 from O3:K6 and its three main pandemic serovariants

Potential peaks contributing to the differentiation of O4:K8 from four other serotypes (O3:K6, O4:K68, O1:K25 and O1:KUT) were identified using ClinProTools 3.0. The performances of three different models (the Genetic Algorithm, the Supervised Neural Network, and the QuickClassifier Algorithm) were evaluated. The Genetic Algorithm produced the best results (99.91% recognition capability and 99.04% cross validation) (Table 3). In addition, the differences between the peaks of O4:K8, O3:K6 and its serovariants (O4:K68, O1:K25, and O1:KUT) at m/z 4383, 4397, 4734, 4785, 9466 and 9569 could be observed in the mass spectra (Fig. 3).

Table 3 The performance of models generated by ClinProTools for the differentiation of O4:K8 from O3:K6 as well as its three serovariants (O4:K68, O1:K25, and O1:KUT)
Fig. 3
figure 3

MALDI-TOF MS spectra of five isolates belonging to five serotypes (O4:K8, O3:K6, O4:K68, O1:K25 and O1:KUT) displayed in FlexAnalysis: (a) Peaks at m/z 4383 and 4397 of O4:K8 compared with O3:K6; (b) Different distribution of two peaks at m/z 4734 and 4785 belonging to O4:K8 and O3:K6, respectively; (c) Comparison of two peaks at m/z 9466 and 9569 belonging to O4:K8 and O3:K6, respectively

The presence or absence of the peaks at m/z 4383, 4397, 4734, 4785, 9466 and 9569 in 146 strains was also recorded (Fig. 4). Among O4:K8 isolates, 35 out of 36 strains contained peaks at m/z 4734 and 9466, and 32 out of 36 strains contained peaks at m/z 4383, 4397, 4734 and 9466 simultaneously. Only two strains of O4:K8 possessed peaks at m/z 4785 and 9569. Only five out of the 110 non-O4:K8 strains contained peaks at m/z 4383 and/or 4397; none of the strains belonging to the four pandemic serotypes (O3:K6, O4:K68, O1:25 and O1:KUT) contained these two peaks. 61 out of 63 isolates of O3:K6 contained peaks at m/z 4785 and 9569. Both isolates of O1:K25 contained two peaks, at m/z 4785 and 9569. But for O4:K68, both of them contained two peaks at m/z 4734 and 9466. Two out of five O1:KUT isolates contained peaks at m/z 4734 and 9466, while the other isolates contained peaks at m/z 4785 and 9569.

Fig. 4
figure 4

The distribution of peaks at m/z 4383, 4397, 4734, 4785, 9466 and 9569 in 146 strains belonging to 23 serotypes are shown in the graph. The black squares highlight the presence of peaks in three replicated spectra of a strain

Discussion

The 146 strains in this study were divided into 23 serotypes; O3:K6 was the most common serotype, followed by O4:K8 and then O8:K41. Notably, isolates of O3:K6 and O4:K8 make up a large proportion of all the analyzed strains. The distribution of serotypes in Zhejiang province was slightly different from that of Jiangsu province, where O3:K6, O5:K17 and O1:KUT were the three major serotypes [26].

Since 1996, serotype O3:K6 with specific genetic markers (with tdh and toxRS/new genes, and with or without orf8 genes) has emerged as a major serotype, causing worldwide outbreaks, including outbreaks in China. Infections associated with serotype O4:K8 have occurred in Peru, where this serotype remains predominant [27]. In China, the number of infections associated with O4:K8 has recently increased. This serotype has emerged as a distinct group that is almost different from O3:K6. Nearly 21 serotypes, including O4:K8 [28], are recognized as serovariants of O3:K6. These serotypes share identical genotypes and molecular profiles [11] and are therefore called “O3K6 clones” or “pandemic strains”. The majority of these have established an ecological niche in Asia [29]. O4:K68, O1:K25 and O1:KUT, which are clonally related to O3:K6, are responsible for pandemic outbreaks [30]. O4:K8, a serovariant of O3:K6, formed a potential predominant clone in South China. Cluster analysis of O4:K8, O3:K6 and O1:KUT showed that all strains of O4:K8 were clustered into one group, while O3:K6 and O1:KUT, isolated from different countries and regions, were clustered into another group [31]. Notably, we found a similar cluster for O4:K8 using proteomic analysis with Biotyper 4.0, while O3:K6, O4:K68, O1:K25 and O1:KUT were clustered into another group. This confirms that O4:K8 represents a threat as a thriving serotype of V. parahaemolyticus infection, which is distinct from O3:K6. Four out of 36 O4:K8 strains were clustered into the same group as O3:K6. This is explained by the fact that O4:K8 is designated as a serovariant of O3:K6. Furthermore, there is a possibility that these four strains had not evolved into a specific group that is different from O3:K6.

Identification of strains using the original commercial database together with our in-house database resulted in a high log score. This indicates that a sufficient number of strains are needed in the database for reliable identification. Biomarker based databases have been illustrated to an optimism method which superior to pattern recognition based databases and Vitek 2™ for the identification of Gram negative bacteria [32]. Several studies have also used ribosomal biomarkers corresponding to sequence types and/or clonal complexes to subtype Neisseria meningitides [33]. A recent study also successfully identified Clostridium difficile genotype ST37 by MALDI-TOF MS, and further characterized two peaks at m/z 3242 and 3286 that were specific for ST37 [34]. In the current study, peaks at m/z 4383 and 4397 appear to be specific for serotype O4:K8, allowing for the discrimination of O4:K8 from O3:K6 and its three other serovariants. Characterization of the two potential biomarkers at m/z 4383 and 4397 is in progress. The inclusion of isolates from different regions should confirm the ability of MALDI-TOF MS to discriminate O4:K8 from other pandemic serotypes. Further attention should be given to infections associated with serotype O4:K8.

Conclusion

This study supports the hypothesis that O4:K8, which thrives as a potential predominant clone, is distinct from O3:K6 and its three main serovariants at the protein level. The use of MALDI-TOF MS in a study of this nature has not been reported before. Furthermore, peaks in the mass spectra at m/z 4383 and 4397 were determined to be specific for O4:K8 over four pandemic serotypes. However, we cannot conclude that MALDI-TOF MS can be used for the serotyping of V. parahaemolyticus. The taxonomic resolution of the MALDI-TOF MS technique is occasionally overestimated, and caution must be exercised when using MALDI-TOF MS to distinguish the serovariants of V. parahaemolyticus and other species.

Materials and methods

Reagents

Ethanol, formic acid, acetonitrile (AN), trifluoroacetic acid (TFA), and α-cyano-4-hydroxycinnamic acid (CHCA) were purchased from Fluka, Germany.

Bacterial strains

A total of 146 strains of V. parahaemolyticus, including 23 serotypes, were tested in this study. All strains were isolated in Zhejiang province, China, and the clinical strains were collected as part of standard care. Whole isolates were grown on TCBS, and then further confirmed by toxR-target PCR amplification. Conventional serotyping was performed by slide agglutination with a V. parahaemolyticus antiserum (Denka Seiken, Tokyo, Japan).

Sample preparation

Bacterial strains were grown overnight on heart infusion (HI) agar. The cultures were harvested and subjected to ethanol-formic acid extraction as previously described [35]. 1 μl of each supernatant was spotted on to a Bruker target plate, and each strain was spotted in 5 replicates. Each spot was overlaid with 2 μl of 10 mg/ml CHCA in 2.5% aqueous TFA and allowed to dry at room temperature.

MALDI-TOF MS parameters and spectrum generation

The spectra were obtained using a microflex LT bench top mass spectrometer (Bruker Daltonik GmbH, Bremen, Germany) using a 20 Hz nitrogen laser and the following parameters: parameter settings: ion source 1 (IS1), 20 kV; IS2, 18.5 kV; lens, 8.5 kV; detector gain, 2650 V; and gating, none. A total of 300 shots per composite mass spectrum were recorded with the positive linear mode in a spectrum range of m/z 2000–20,000. The instrument was externally calibrated with a bacterial test standard (BTS, Bruker Daltonics). Theoretical and measured masses matched within 300 ppm. After calibrating manually, 20 independent spectra from different laser aiming spots of one sample were obtained.

MSP library construction

Thirty five isolates were randomly selected for use in the in-house database (Table 2), all of which belonged to O3:K6, O4:K8, O1:K5, O1:KUT or O4:K68. Twenty spectra, representing five technical replicates, were collected for every strain/isolate. The remaining 75 strains were analyzed for evaluation of this database. The spectra preprocessing parameters included mass adjustment (lower bound = 3000, upper bound = 15,000, resolution = 1, data reduction factor = 10), smoothing (Savitzky-Golay algorithm with a frame size 25 Da), baseline correction (multipolygon with number of run 1), normalization (maximum norm, the spectrum was normalized to a maximum peak value of 1), and peak detection (spectra differentiation with maximum peaks of 100 and threshold of 0.001). Main spectrum profiles (MSPs) were created for each strain using the following parameters: maximum mass error of each single spectrum = 6000, mass error for the MSP = 200, peak frequency minimum = 5%, maximum peak number = 100.

Log (score) values ≥2.0 were considered for species-level identification and log (score) values < 2 and ≥ 1.7 for were considered for genus-level identification. Results based on log (score) values < 1.7 were rated as unidentifiable. For species identification, raw spectra of 146 isolates were imported into the BioTyper software and matched against the commercial database (with default parameter settings). Comparisons between the commercial database and the expanded database after the introduction of the in-house database were also conducted. Spectra of the remaining 75 strains, which belonged to pandemic serotypes and were not used for database construction, were loaded into MALDI Biotyper Compass Explorer 4 and matched against the commercial database with 8223 MSPs entries and the expanded database after the introduction of the in-house database.

Phyloproteomic analysis of V. parahaemolyticus

To further evaluate the proteomic relatedness of different serotypes, dendregram analyses for 146 strains of 23 serotypes and 110 strains of five serotypes (O4:K8, O3:K6, O4:K68, O1:K25 and O1:KUT) were performed using BioTyper 4 software (Bruker Daltonics). These analyses were based on MSPs with the default parameters. The distance measurement was set to “correlation” and the linkage algorithm was set to “average”, while Vibrio vulnific ATCC27562 was included as an out-group.

The differences between O4:K8 and the four other main pandemic serotypes (O3:K6, O1:K25, O1:KUT and O4:K68) were further analyzed using PCA and CCI [36]. Dendrograms obtained in PCA represented the closeness of each spectrum to one another [37]. The default parameters of PCA clustering were set to “hierarchical”, the distance measurement was set to “correlation” and the linkage algorithm was set to “average”. To further evaluate the spectral variation (similarity) between the spectra sets acquired from these five main pandemic serotypes, the CCI was calculated using MALDI Biotyper Compass Explorer 4. All measured spectra were loaded and the CCI was calculated using the following settings: mass lower bound = 3000, mass upper bound = 12000, resolution = 4 and CCI parameter interval = 8. A CCI value of 1 indicates complete correlation between the spectra, while a value of 0 indicates no correlation. The CCI values were extracted and the displayed image was redrawn using the conditional formatting option in MS Excel.

Identification of potential peaks that contribute to the differentiation of O4:K8 from the other four serotypes using ClinProTools

We generated three models to identify potential biomarkers that differentiate O4:K8 from the four other main serotypes (O3:K6, O4:K68, O1:K25 and O1:KUT) using ClinProTools. We used three algorithms: the Genetic Algorithm, the Supervised Neural Network, and the QuickClassifier Algorithm. All isolates of O4:K8 were used as a target group, while the other strains were used as a control group. Mass data files of these two groups were transferred into ClinProTools and recalibrated with the default parameters of 1000 ppm maximal peak shift. Several mass peaks (m/z) with significant differences were selected for classification by the model.