Objectives

The aim of this analysis was to look at the impact of gender on LV geometry and the predictors of myocardial perfusion reserve (MPR) in severe aortic stenosis (AS).

Background

It is well recognised that cardiac size is different between the two genders, even when corrected for body size. In AS echocardiographic studies suggest women have higher relative wall thickness and better preserved left ventricular (LV) ejection fraction (EF). There are little cardiac magnetic resonance (CMR) data on gender differences in severe AS, in particular MPR.

Methods

Forty-one patients with isolated severe AS without obstructive coronary artery disease underwent adenosine stress perfusion CMR in a 1.5T scanner (Siemens Avanto); MPR was calculated from absolute myocardial blood flow during adenosine hyperaemia and rest determined by model-independent deconvolution of signal intensity curves with an arterial input function. Transthoracic echocardiography was used to assess AS severity, tissue Doppler derived diastolic function, LVRPP (LV rate pressure product=[systolic blood pressure(SBP) + peak aortic valve gradient]*heart rate) an estimate of myocardial work, and diastolic perfusion time (DPT=[R-R interval - LV ejection time]*heart rate).

Results

Females were older with significantly lower body surface area (BSA) and higher SBP. Despite equivalent AS severity females had significantly lower LV mass index (LVMI), LV volumes and wall thickness (relative and absolute), less late gadolinium enhancement (LGE) and higher EF. Resting and hyperaemic myocardial blood flow (MBF) were higher in females although MPR remained the same. Results are summarised in Tables 1 and 2. Variables with the strongest correlation with MPR in females were mean pressure gradient (PG), LGE, LVRPP, and DPT in contrast to LV mass, relative wall thickness and septal E/E’ in males, Table 3.

Table 1 Demographics and Echocardiographic Data
Table 2 CMR Data
Table 3 Correlations with MPR

Conclusions

These findings confirm the gender differences in LV geometry in response to pressure overload. The factors contributing to microvascular dysfunction also appear to be different. In males increased LV mass and relative wall thickness with associated diastolic dysfunction appear to be important determinants of microvascular dysfunction, in contrast to females where pressure gradients and diastolic perfusion time play a larger role. Paradoxically LVRPP was positively correlated with MPR in females. These differences may have implications for the treatment of microvascular dysfunction in females compared with males.