Abstract
An ion-selective electrode for lead(II) based on a dispersion of N,N"-bis(3-methyl salicylidine)-p-phenyl methane diamine particles into a polymeric membrane using coated-wire configuration is described. Membranes based on polyvinyl chloride containing different amounts of plasticizer and ionophore are studied. The best performance in terms of slope (30.3 ± 0.6 mV per decade) and response time (<15 s) is displayed. The sensor shows a Nernstian response for Pb(II) ions over a wide concentration range of 2.0 × 10–5 to 0.10 M. The sensors can be used for more than three months without any considerable divergence in potentials. The selectivity is also good towards the most common univalent and divalent cations and the signal is constant in the pH range 1.6–6.0. An application to lead determination in mineral rocks and wastewater proved to be a success, and it was employed as an indicator electrode in potentiometric titration of CrO2– 4 with lead ions.
Similar content being viewed by others
References
Ammann, D., Morf, W.E., Anker, P., Meier, P.C., Pretsch, E., and Simon, W., Ion-Select. Electrode Rev., 1983, vol. 5, p. 3.
Shpigun, L.K., Novikov, E.A., and Zolotov, Yu.A., Zh. Anal. Khim., 1986, vol. 41, p. 617.
Mousavi, M.F., Sahargi, S., Alizadeh, N., and Shamsipour, M., Anal. Chim. Acta, 2000, vol. 414, p. 189.
Zareh, M.M., Ghoneom, A.K., and El-Aziz, M.H.A., Talanta, 2001, vol. 54, p. 1049.
Mousavi, M.F., Barzegar, M.B., and Sahargi, S., Sensors Actuators B, Chem., 2001, vol. 73, p. 199.
Xu, D. and Katsu, T., Anal. Chim. Acta, 1999, vol. 401, p. 111.
Tavakkoli, N., Khojasteh, Z., Sharghi, H., and Shamsipour, M., Anal. Chim. Acta, 1998, vol. 360, p. 203.
Malinowska, S., Analyst (Cambridge, UK), 1990, vol. 115, p. 1085.
Abbaspour, A. and Tavakoli, F., Anal. Chim. Acta, 1999, vol. 378, p. 145.
Casanati, G., Tetrahedron Lett., 1965, p. 234.
Jeffery, G.H., Basset, J., Mandham, J., and Denney, R.C., Vogel's Textbook of Quantitative Chemical Analysis, London: ELBS, 1991.
Kamata, S., Bhale, A., Fukunage, Y., and Murata, A., Anal. Chem., 1988, vol. 60, p. 2464.
Srinivasan, K. and Rechnitz, G.A., Anal. Chem., 1969, vol. 41, p. 1203.
Tavakkoli, N. and Shamsipour, M., Anal. Lett., 1996, vol. 29, p. 2269.
Ammann, D., Pretsch, E., Simon, W., Lindler, E., Bezegh, A., and Pungor, E., Anal. Chim. Acta, 1985, vol. 171, p. 119.
Huser, M., Gehrig, P.M., Morf, W.E., Simon, W., Lindler, E., Jeney, J., Toth, K., and Pungo, E., Anal. Chem., 1991, vol. 63, p. 1380.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Mazlum Ardakany, M., Ensafi, A.A., Naeimi, H. et al. Coated, Wire-Based, New Schiff Base Potentiometric Sensor for Lead(II) Ion. Russian Journal of Electrochemistry 39, 269–273 (2003). https://doi.org/10.1023/A:1022819609588
Issue Date:
DOI: https://doi.org/10.1023/A:1022819609588