Introduction

E-DCR is a widely acceptable and common surgical procedure for primary acquired nasolacrimal duct obstruction in which a communication between the lacrimal sac mucosa and nasal mucosa is created [1]. Because E-DCR has disadvantages such as leaving incision scars, more noninvasive surgical procedures have been developed. Despite the advantages of multidiode laser DCR or endoscopic DCR, such as no incision scarring or less hemorrhaging during the procedure, E-DCR failures are less frequent than those of these techniques [2, 3]. Some studies in the literature report failed E-DCR rates of 5–10% [46] to 35–40% [79]. E-DCR is usually preferred for the treatment of failed DCRs. In this study we aimed to report our rE-DCR results after various failed DCR surgeries.

Methods

From June 2006 to June 2015 at Yıldırım Beyazıt University Ankara Ataturk Training and Research Hospital Department of Ophthalmology, a total of 41 eyes of 40 patients who underwent rE-DCR procedures performed after failed DCRs were gathered from the department files, retrospectively. All patients were operated on by the same surgeon under general anesthesia. All patients were suffering from epiphora. There was no trauma history in any of the patients before the epiphora occurred and no ocular abnormalities. Preoperatively, after a standard ocular examination including visual acuity, biomicroscopic anterior segment and fundus examination, to confirm nasolacrimal duct obstruction, nasolacrimal duct irrigation was done, and blocked syringing was seen in all 40 patients. All patients consulted an ear, nose and throat (ENT) specialist to detect any nasal pathology. Especially if a nasal septum deviation on the same side as our surgical area was reported by the ENT specialist, we postponed our rE-DCR surgery until the patient had undergone nasal septum surgery because a nasal septum deviation blocking the inferior nasal concha and Hasner valve would make our surgery more difficult.

A J-shaped skin incision was made with a surgical knife over the sac area. The periosteum overlying the lacrimal fossa and the area above were elevated with a periosteum elevator. If the bone osteotomy size was insufficient, smaller than 10 × 10 mm, it was expanded with a Kerrison punch. The lacrimal sac was opened in a longitudinal fashion to form anterior and posterior lacrimal flaps unless it had not been opened before. If the failed DCR surgery was an E-DCR, it was obviously harder to recreate flaps than for the other failed DCR techniques because of the existence of granulation and fibrotic tissue. Lacrimal sac mucosa and nasal mucosa were fashioned in an H shape, respectively. After controlling hemorrhaging, anterior and posterior mucosal flaps were sutured using 6.0 vicryl, and all patients were silicone intubated. The subcutaneous tissue and skin were then sutured using 6.0 vicryl in a continuous fashion. Mitomycin C was used particularly in patients who had excessive granulation tissue at the surgical area, especially surrounding the sac and previous flaps; 0.02% mg/ml mitomycin C was used between the flaps with a surgical sponge saturated with the drug for approximately 2 min and then irrigated. A nasal pack with antibiotic ointment was placed at the end of the surgery. After 24 h, the nasal pack was removed, and syringing was done from the lower punctum to check the patency of the lacrimal passage. Postoperatively, patients were given amoxicillin-clavulanate and naproxen sodium tablets twice a day for 7 days and local netilmicin-dexamethasone and ketorolac eye drops for 2 weeks. The skin sutures were removed after 7 days. The silicone tube was removed at least after 6 months. The patients were followed up at the 1st week and 1, 3, 6 and 12 months. The patients who were followed up less than 3 months were excluded. Successful rE-DCR was defined as relief of symptoms and an open passage at nasolacrimal syringing. All procedures followed were in accordance with the ethical standards of the responsible committee on human experimentation (institutional and national) and with the Helsinki Declaration of 1964, as revised in 2013. Informed consent was obtained from all patients for being included in the study.

Statistical Analysis

We used Windows SPSS version 16.0 and descriptive statistics to evaluate our surgical outcomes and to calculate our mean values.

Results

The mean age was 48.95 ± 12.59 years (range 19–69). There were 31 females (77.5%) and 9 males (22.5%). Two of our patients underwent failed DCR twice, and 38 patients underwent failed DCR once. Six of these previous failed DCRs were multidiode laser DCRs (14.6%), 2 were endoscopic DCRs (4.8%), and 33 were external DCRs (80.4%). Three of these 41 failed surgeries had taken place in our clinic before, and all of these failed DCR surgeries were E-DCRs. The mean time was 76.4 ± 107.7 months (range 1–420 months) between the previous failed DCR and our rE-DCR. The mean time for epiphora compliant recurrence after failed DCR was 2.39 ± 1.40 months (range 1–6 months). After rE-DCR, the mean follow-up time was 38.9 ± 35.7 months (range 3–67 months). The mean silicone tube removal time was 6.2 ± 1.06 months (range 6–12 months).

Among 33 failed E-DCR surgeries, we detected excessive granulation tissue in 85% of the patients during the surgery. Also among eight failed multidiode laser and endoscopic DCR surgeries, we detected inadequate osteotomy sites (<10 × 10 mm) in 83% of the patients during surgery.

One of our patients who underwent failed DCR twice had E-DCR surgery, and the other patient underwent laser DCR twice and failed both. At the last examination after revision surgery, the patient who had two failed E-DCR surgeries had a blocked nasolacrimal duct passage. Intraoperatively, there was excessive granulation tissue. However, the patient who had two failed multidiode laser DCR surgeries, who had an inadequate osteotomy site intraoperatively, now has an opened nasolacrimal passage and no complaints.

At the last examination, six patients still had epiphora (15%) and were blocked when using the syringing nasolacrimal apparatus. Five of these patients were female and one male. Three of our patients' epiphora complaints continued just after our rE-DCR surgery, and the other three patients' complaints recurred 1 month after the rE-DCR surgery. Five of these patients' previous surgeries were E-DCRs, and one patient had endoscopic DCR surgery. We used 0.02% mitomycin C on four of these six patients because of excessive granulation tissue at the operation site. Thirty-four patients had no complaints, and their passages were open. The overall success rate was 85% (Table 1).

Table 1 Our rE-DCR Success Rates

Discussion

In this series of 41 failed DCRs, reoperation using the rE-DCR technique had an 85% success rate. Ari et al. evaluated their 14 months of follow-up results of rE-DCR surgeries and reported 85% anatomical success and 78% both anatomical and functional success [10]. Our success rate is compatible with that of primary operated DCRs [1, 11, 12]. It is well known that success in DCR surgery is compromised by anatomical or functional problems such as a small osteum or blockage of the osteum or canalicular system because of fibrosis [12, 13]. Intraoperatively, we observed that the reason for the failure in the previous DCR was likely not creating a proper osteum, especially for laser-assisted and endoscopic DCRs. In previous failed E-DCRs, we detected excessive granulation tissue at the operation site as the main reason for failure.

It has been shown that the success rate can be increased by using intraoperative mitomycin C, an antiproliferative agent placed over the anastomized posterior flaps and osteotomy site [13]. In our study, we used mitomycin C in cases with excessive fibrosis and granulation tissue.

Another important point in revision cases is usage of silicone stents. Some studies report that leaving in silicone tubes for a long time may cause more granulation tissue, but some authors suggest long-term use particularly in revision cases [1416]. Therefore, because of these studies and our clinical experiences, we left the silicone tubes in for at least 6 months after revision surgery in our cases. But it is obvious that if the patient does not return for his or her follow-up on time, the time with a silicone stent is extended unintentionally.

In different study series, the frequency of recurrent epiphora after DCR surgery is reported as 5% to 17% [17, 18]. The most important factors that play a role in the failure of a DCR surgery are inadequate rhinostomy, excessive scar tissue proliferation, anatomic anomalies and concomitant paranasal sinus infections [19]. There have been many surgical attempts for failed DCRs. In general, the preferred revision DCR surgeries after a failed DCR are endoscopic non-laser, multidiode laser, external or transcanalicular laser diode DCR.

Many studies have compared whether revision endoscopic or external DCR gives better results after failed DCR surgeries [18, 20]. Although recent studies report similar success rates in revision endoscopic DCR and rE-DCR, due to less scarring and providing a chance to interfere with endonasal pathologies, endoscopic revision surgeries have been praised [1921]. It is also known that, as a disadvantage, the endoscopic DCR procedure requires more surgeon experience and more surgical tools. With the rE-DCR procedure we were able to remove the granulation tissue from the drainage site and easily expand the former and inadequate osteotomy. We think that our high success rates for rE-DCR procedures are correlated with our mitomycin C usage in the appropriate patients, leaving the silicone tube in for a sufficient time and removing the silicone tube at the appropriate time in all patients. Although many different DCR surgical procedures have been described, rE-DCR is likely the gold standard surgical technique after failed DCR surgery [1, 22, 23]. The retrospective nature and small patient number are the main limitations of this study; the long follow-up duration is its main strength.

Conclusion

Despite the new techniques in primary acquired nasolacrimal duct obstruction, external DCR is still a safe and effective surgical procedure. However, there is always a possibility of failure in all surgical procedures. For revision surgeries, usage of silicone tubes and mitomycin C and creating a proper osteum are the most important factors for a successful surgery. As a result, the rE-DCR procedure, as a highly appropriate revision surgery for failed DCRs, has a high success rate, strengthened by the usage of a silicone tube and mitomycin C and creation of a proper osteum.