Abstract
Wound dressings are used during patient radiotherapy treatments, particularly in cases of radiation induced lesions. Potentially, the presence of a dressing may increase the dose to the skin, further aggravating the skin reaction and decrease the dose at depth. The changes are dependent on linear accelerator beam type and beam quality and were determined for 4 and 10 MV photon energies and 6 and 15 MeV electron energies using a slab phantom and fixed separation parallel plate chambers. Since these dressings have been designed to be used on exuding wounds, measurements were taken under eight different wound dressings in both dry and wet state. Irradiations with photon energies increased the skin dose significantly (max. increase: 68.1 %; average increase: 48 %) with little or no change to dose at depth. Electron beam energies showed little or no change to doses at the surface, but the dose distribution was shifted towards the surface. The maximum decrease in dose at depth was 3.6 % for 6 and 15 MeV through all dressings except one and was therefore considered to be clinically insignificant. A change in dose at surface of 9.7 % and at R50 of 25.9 %, equivalent to a shift of dose towards the surface of 7.5 mm, was measured for one dressing. This demonstrates that it is possible for a wet dressing to significantly alter electron beam dosimetry.
Similar content being viewed by others
References
Thilman C, Adamietz IA, Ramm U, Moses S, Saran F, Bottcher HD (1996) Radiation load on the skin using a silicone-coated polyamide wound dressing during photon and electron radiotherapy. Strahlenther Onkol 172:270–274
Thilmann C, Adamietz IA, Moses S, Saran F, Ramm U, Bottcher HD (1996) Increase of surface dose using wound dressings during percutaneous radiotherapy with photons and electrons. Radiother Oncol 40:181–184
Thilman C, Adamietz IA, Ramm U, Rahn A, Straβmann G, Moses S, Saran F, Bottcher HD (1995) TLD measurements of the increase of surface dose due to wound dressings during percutaneous irradiation. Eur J Cancer 31(6):42
Butson MJ, Cheung T, Yu PKN, Metcalfe P (2002) Measurements of skin dose variations produced by a silicon-based protective dressing in radiotherapy. Phys Med Biol 47:N145–N151
http://global.smith-nephew.com. Accessed 1 October 2011
http://www.molnlycke.com/au/. Accessed 1 October 2011
http://www.convatec.com.au. Accessed 1 October 2011
PTW User Manual, Ionization Chamber Type 34001 (Roos Chamber), D329.131.0/2, 2006- 01, Hn
Andreo P, Almond PR, Mattsson O, Nahum AE, and Roos M (1995) IAEA TRS-381, The use of plane parallel ionization chambers in high energy electron and photon beams. An International Code of Practice for Dosimetry, Dec 1995
ICRU Report 39 (1985) Determination of dose equivalents resulting from external radiation sources, International Commission on Radiation Units and Measurements, Bethesda
ICRP Publication 60 (1991) 1990 recommendations of the International Commission on radiological Protection, Pergamon Press, Oxford, pp 149–153
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mac Nally, C., Woodings, S. Changes to dose at surface and shifts of dose distributions at depth through dry and wet wound dressings for photon and electron beam radiotherapy. Australas Phys Eng Sci Med 35, 245–250 (2012). https://doi.org/10.1007/s13246-012-0139-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13246-012-0139-z