Introduction

Arsenic water contamination is a common problem among the indigenous of Bangladesh where estimated population of about 35 million are consuming water with arsenic level above 50 μg/L (national standard level) and fivefold higher than the World Health Organization (WHO) guideline (BGS and DPHE 2001; WHO 2011). However, the source of this contamination is controversial but available evidence suggested that agricultural, industrial activities and geological conditions are the major risk factors. Water analysis of the affected area has revealed to contain high level of As(III) species thus rendering the water unsafe for drinking.

The previous studies have shown that ground water contained oxyanions of arsenic species (Cullen and Reimer 1989; Masscheleyn et al. 1991). The predominant form in well-oxidized water is As(V), whereas As(III) occurs mainly in reduced environments. Meanwhile, As(III) has a toxicity that is sixty times greater than that of As(V) and is difficult to remove without oxidation (Kim et al. 2003).

Many different techniques have been developed to remove arsenic from groundwater. These include adsorption, adsorptive filtration, coagulation, membrane filtration, ion exchange and reverse osmosis (Ahmed 2001; Wang and Wai 2004). For most of these technologies, oxidation is required to remove overall arsenic, because As(III) is not adsorbed by solid material such as iron oxides and hydroxides, alumina or clays (Anderson et al. 1976; Lievremont et al. 2003; Gupta et al. 2005). In Bangladesh, simplest common inexpensive technique used is arsenic–iron removal plant (AIRP). The basic principle involves the use of AIRP to remove arsenic using iron as co-precipitating factors. As–Fe complex can be easily removed as sludge by sand filtration.

Oxidation of As(III) under atmospheric condition is an extremely slow process, and hence, chemical oxidants such as chlorine, hydrogen peroxide and ozone are widely used in arsenic removal processes (Kim and Nriagu 2000; Simeonova et al. 2005). Some researchers suggest that microbial activity could also contribute to the oxidation of As(III) (Quéméneur et al. 2008; Hamamura et al. 2009). In fact, many have isolated phylogenetically diverse arsenite-oxidizing bacteria (AsOB) from various environmental samples, including wastewater (Butt and Rehman 2011), sewage (Ito et al. 2012), mines (Santini et al. 2000; Battaglia-Brunet et al. 2006; Lugtu et al. 2009), soil (Bahar et al. 2012) and sediments (Dominguez et al. 2008). Ito et al. (2012) found the contribution of biological As(III) oxidation in a laboratory-scale bioreactor where an isolate closely related to Ensifer adhaerens was immobilized.

Recent molecular studies have revealed the distribution of the diverse arsenite oxidase gene such as aroA/asoA/aoxB in various As-contaminated environments (Inskeep et al. 2007; Quéméneur et al. 2008; Hamamura et al. 2013,). Contribution of rapid biotic As(III) oxidation was found in spring outflow channel waters, and bacterial arsenite oxidase gene was detected in channel soil samples (Mitsunobu et al. 2013). However, little or no information is available on the role of microbial As(III) oxidation in the sand filtration units of AIRPs.

Thus, this study aimed to examine the contribution of biological activity on As(III) oxidation in the sand filtration units of AIRPs. Arsenic speciation and removal were evaluated in AIRP plants in Bangladesh. A batch experiment with AIRP sand samples was conducted to evaluate oxidative activity. We also identified the bacterial gene for arsenite oxidation in the AIRP sand samples. We therefore concluded that sand units of AIRP offer biological activity that enhances arsenic removal.

Materials and Methods

Water and sand sample collection

Water and sand samples were collected from AIRP plants at Manikganj District, Bangladesh. Series of samples were taken from a municipal AIRP (MAIRP) (location: 23°51′05″N, 90°00′04″E). The plant serves treated water to the municipality. The capacity of the plant was 5500 m3/day. The schematic of the treatment plant is described in Fig. 1. Briefly, groundwater is pumped up and subjected to primary aeration by exposing the water to the atmosphere (1). Next, the water flows into the sedimentation pond (2) to remove the formed precipitates, followed by gravel filtration (3). After that, the water is again aerated by flowing down a stepped channel (4), where it then flows into the sand filtration unit (5). There were four parallel sand filtration units, the dimensions of which are each 3.35 m width, 6.4 m length and 1.5 m deep. In total, sand volume was 129 m3. The filtrated water is stored in the storage tank (6) before distribution. For this study, water samples were collected from four points, namely Primary aeration, Sedimentation pond, Secondary aeration and Storage tank. Sand samples were collected from the upper part of the sand filtration chamber and from the layer below the precipitated iron.

Fig. 1
figure 1

MAIRP treatment plant (1. Primary aeration, 2. Sedimentation pond, 3. Gravel filtration unit 4. Secondary aeration, 5. Sand filtration unit and 6. Storage tank). Solid line arrows represent the sampling points of the water samples

Also, water and sand samples were taken from three household AIRPs (HAIRPs: H1AIRP, H2AIRP, H3AIRP, respectively) from the same district. HAIRPs are simple treatment plants where the pumped groundwater is poured onto a sand filter unit for arsenic and iron removal. Water was collected before and after the sand filter of the HAIRPs, and sand was collected from the sand filter below the iron precipitates observed in all the AIRPs.

In both MAIRP and HAIRPs, approximately, 40 ml of water samples was filtrated through 0.2 μm (polyethersulfone, Advantec, Japan) disposable filter and subsequently, half of the water samples were passed through disposable arsenic speciation cartridges (MetalSoft Center, USA) that were attached to a 20-mL disposable syringe (Terumo, Japan) to remove As(V) (details of the cartridge are given in the section of chemical analysis) (http://www.metalsoftcenter.com, accessed 31.11.2012). Thus, we had two portions of water samples each 20 ml, one portion is free of As(V) and the other is not free. Following these separation, the two portions of water samples were then acidified with HNO3 to be kept at 0.1 N. The samples were kept in ice or in the refrigerator during transportation to Japan.

Batch experiment on biological arsenite oxidation

Three hundred milliliters of synthetic medium amended with 200 μg/L of dissolved As(III) and 2.5 gm of wet sand were incubated at 25 °C according to Ito et al. (2012) with little modification. The medium consisted of the following ingredients per liter of autoclaved Milli Q water: MgSO4·7H2O, 4.0 mg; NH4Cl, 2.0 mg; Na2SO4, 2.0 mg; K2HPO4, 0.02 mg; CaCl2·2H2O, 0.13 mg; FeSO4·7H2O, 0.008 mg; NaHCO3, 1.6 mg and NaAsO2, 0.35 mg [0.2 mg as As(III)]. Abiotic control was also prepared by adding 6.5 g/L of sodium azide. We properly stirred the mixture and then took water samples for analysis at interval of 0, 6, 12, 24, 36, 48-h from both bottles. The procedure for the analysis was similar as described above. Triplicate batch experiments were done for both test and control batches.

From the balance of As(V) increase between test batch and abiotic control, capacity of biological arsenic oxidation rate (Cbao, µg/h) was calculated:

$$ C_{\text{bao}} = \frac{{S_{\text{f}} \times V}}{T \times M}\left( {I_{\text{t}} - I_{\text{c}} } \right) $$

where \( S_{\text{f}} \), amount of the sand in the actual sand filtration unit (g); \( V \), volume of the media in the batch test (L); \( T \), incubation period of the batch test (h); \( M \), amount of sand used in batch test (g); \( I_{\text{t}} \), increase in dissolved arsenate in the test batch (µg/L); \( I_{\text{c}} \), increase in dissolved arsenate in the control batch (µg/L)

Chemical analysis

Disposable cartridges made up of 2.5 g aluminosilicate adsorbent in a polypropylene narrow column of length 10.16 mm and diameter 0.76 mm was used to remove As(V) from the samples. At the beginning of this study, the efficiency of this cartridge to remove As(V) was established using sodium meta-arsenite (NaAsO2) and sodium arsenate (Na2HAsO4·7H2O). The cartridge recorded 95% efficiency in the removal of As(V) (data not shown). It is therefore adopted in the experiment by measuring the arsenic concentration of the samples before and after passing through cartridges. The balance between the two measurements gave As(V) concentration. For the analysis of arsenic and iron, samples were acidified (1%, v/v) and analyzed by inductively coupled plasma-mass spectrometry (ICP-MS, 7500cx: Agilent Technologies, Japan). Gallium (0.1 mg/L) and scandium (0.1 mg/L) solutions were used as internal standards for arsenic and iron, respectively, and helium (He) gas mode was used for the analysis of both elements.

PCR amplification, cloning and sequencing of aoxB gene

Genomic DNA was extracted from 0.5 g sand using a fast DNA spin kit for soil (MP Biomedicals) following the manufacturer’s instructions. The polymerase chain reactions (PCR) for the amplification of arsenite oxidase gene (aoxB) were carried out in a 50 μL reaction mixture containing 100 ng DNA template, 1 μL of each forward and reverse primer (100 μM), 10X Takara Ex Taq™ PCR buffer (contains 20 mM MgCl2) 5 μL, dNTP mixture (2.5 mM each dNTP) 4 μL, TaKaRa Ex Taq HS (5 units/μL) 0.25 μL and nuclease free water up to 50 μL. The degenerated primers (69F:5′-TGYATYGTNGGNTGYGGNTAYMA3′; 1374R:5′-TANCCYTCYTGRTGNCCNCC-3′) (Rhine et al. 2007) were employed for the amplification of arsenite oxidase gene. Nucleic acids extracted from Alcaligenes faecalis strain LMG 3368 were used as a positive control for PCR amplification. All PCR amplifications were performed in the thermal cycler (Veriti 200, Applied Biosystem). The initial denaturation step was begun at 95 °C for 5 min, followed by 35 cycles of denaturation at 94 °C for 30 s, annealing at 58 °C for 30 s, and extending to 72 °C for 2 min, with a final extension at 72 °C for 10 min. All PCR products were checked by gel electrophoresis on a 1.5% agarose gel at 100 V for 15 min, and the specific bands were visualized under UV trans-illuminator.

PCR products of aoxB gene were purified using a QIAGEN purification plus kit. Cloning was performed using a QIAGEN PCR cloning kit (QIAGEN) according to manufacturer’s instruction. PCR products were ligated into a pDrive cloning vector and were transformed into the QIAGEN EZ competent cells. The transformants were then grown on an LB agar plate containing ampicillin, IPTG and X-gel at 37 °C until colony formation (~ 17 h). The positive recombinant colonies (white colonies) were selected according to blue–white screening. The white colonies were directly amplified by using the primers of M13f (-40) and M13r. The products were checked by gel electrophoresis and sent to the company (FASMAC, Kanagawa, Japan) for sequencing.

The initial sequence analysis was performed using Blast service (http://blast.ddbj.nig.ac.jp). ClustalW tool was used for sequence alignment. Neighbor-joining phylogenetic tree was constructed by MEGA version 5.0 (Tamura et al. 2011).

Results and discussion

Removal of arsenic in AIRP

The concentration of total dissolved arsenic (total D-As) in that raw water (groundwater) of MAIRP as presented in Fig. 2 is 13 μg/L which is considerable lower than the standard value for Bangladeshi drinking water (50 μg/L) (http://www.dphe.gov.bd, accessed 12.12.2018) but however higher when compared with the WHO guideline value (10 μg/L) (www.who.int/water_sanitation_health/dwq/chemicals/arsenic.pdf, accessed 12.12.2018). Of the total D-As obtained in the study, very tiny fraction is arsenate [As(V)] which is consistent with previous reports (DPHE/BGS/MML 1999; Smedley et al. 2001). In groundwater, arsenic mainly exists in two inorganic forms, As(III) and As(V); our result thus confirmed the abundance of arsenite [As(III)] though tendency to contain other species of arsenic is not disputable.

Fig. 2
figure 2

Concentration of total arsenic and dissolved iron in MAIRP

Furthermore, the outcome of total D-As after sedimentation increased to 32 μg/L. The observation has been linked with changing of the solid phase to the dissolved phase of arsenic. Previous report (Hasan et al. 2009) described mechanism of bioleaching associated with sand filter bed that creates a biofilm in pore space and top of the surface of the bed creating an anaerobic condition that facilitates the bioleaching of arsenic in the outlet water. This mechanism may probably be responsible for the increment in D-As obtained in this study. However, negligible changes in concentration were observed in total D-As after secondary aeration, while D-As(V) remained unchanged (Fig. 2).

Importantly, apart from 33.3% reduction in total D-As obtained after sand filtration, significant reduction and increment in reduced arsenic mainly As(III) and D-As(V) were, respectively, observed. This may suggest that arsenic oxidation took place during sand filtration. Unfortunately, total D-As concentration was not only higher than raw water but also above the WHO value. Thus, MAIRP is not sufficient for arsenic removal. Meanwhile, increment in concentration may be induced by the sediments in the sedimentation pond as described by Hasan et al. (2009). It is therefore suggested that periodic removal of sediment will help to avoid the leaching of arsenic.

Along with arsenic concentration, dissolved Fe (D-Fe) concentration was also measured and it was found to reduce from 6.4 mg/L in the raw water to 0.05 mg/L both in after secondary aeration and in the storage tank. It has been shown in many studies (Hug et al. 2008, Meng et al. 2002, Roberts et al. 2004) that As(V) easily co-precipitates with iron and gets removed from the water. Our result (Fig. 2) is consistent with this observation, whereas iron co-precipitation is often depleted in reduced arsenic hence no obvious removal of arsenic in sedimentation pond. Precipitation of As(V) was limited in due to the lack of enough D-Fe after sand filtration. This phenomenon is in line with Meng et al. (2001).

We also evaluated arsenic and iron concentration before and after sand filtration in the HAIRPs (Fig. 3). Among the three HAIRPs, H1 and H3AIRP removed arsenic well, whereas H2AIRP did not. In H2AIRP, arsenic concentration in the outlet was still higher than the WHO standard (10 μg/L). Most part of the D-As was reduced arsenic in the inlet and then converted to D-As(V) in the plants. Dissolved iron concentration was found to differ in the inlet water of H1AIRP(15 mg/L), H3AIRP(13 mg/L) and 0.8 mg/L in H2AIRP, but all the plants have similar iron concentration (0.06 mg/L) after sand filtration. The low dissolved iron concentration in H2AIRP seems not enough to co-precipitate with arsenic and thereby arsenic removal is inadequate.

Fig. 3
figure 3

Concentration of dissolved arsenic and iron in the HAIRPs

Biological activity of As(III) oxidation

Investigation of biological activities responsible for arsenic oxidation is the main focus here. This was done by batch experiment to observe the impact of microbial activity on As(III) oxidation using sodium arsenite solution on sand sample. An abiotic control was prepared by adding sodium azide. Here, the balance between total D-As and D-As(III) should be D-As(V).

The total D-As and D-As(V) concentration in the batch experiment with MAIRP (Fig. 4) and HAIRPs sands (Figs. S1–S3). In both cases, the total D-As in test and control batches are comparable and gradually decreasing along the incubation time. This may be due to the abiotic activities such as adsorption of arsenic onto the sand particulates or the precipitation of arsenic from the dissolved phase to the solid phase.

Fig. 4
figure 4

Arsenic concentration in test (a) and control (b) batch

A gradual increase in D-As(V) was observed in the test case, whereas in the abiotic control it remained constant throughout the incubation period. At the beginning of the batch test, D-As(V) originated from the stock solution of sodium arsenite, as we observed even in the fresh solution. After 48-h incubation, it was found that the amount of D-As(III) was 19 μg/L in the test case and 76 μg/L in the control. Thus, it depicts more removal of D-As(III) in the test batch which can ascribed to the oxidation of D-As(III) to D-As(V). Hence, the oxidation is biological as it occurred only in the test batch.

Despite variation in the concentration of D-As(V) as observed in this study, total D-As concentration remained unchanged in both test and control batches. Thus, suggesting that precipitation and/or adsorption of D-As was not enhanced by the oxidation of As(III) to As(V). We noted that, before this experiment, the sand was washed to remove Fe particles to reduce the D-As removal rate, as it was too rapid to observe biological arsenite oxidation with the original sand in the preliminary test.

We next considered the potential of biological oxidation in the AIRP unit. Based on the batch experiment of MAIRP, the arsenite oxidation rate was 0.15 μg/h/g-sand. This further gave assumptive estimation of 36 g/h for biological oxidation rate. The loading of the reduced arsenic to the sand filtration unit is 6.3 g/h (calculated from 27 μg/L arsenite in the influent to the sand filtration unit and the flow rate of 5500 m3/day). Therefore, it can be inferred that sand has enough capacity to biologically oxidize all arsenite in the influent as shown in (Table S1).

Detection of arsenite oxidase aoxB gene sequences

With degenerated oligonucleotide primers, a fragment of the large subunit of aoxB was amplified from the genomic DNA extracted from the sand samples. The aoxB gene was detected from the MAIRP sand sample. The size of the amplicon was approximately 1400 bp, as expected. The PCR product was cloned, and four clones were obtained for sequencing.

Figure 5 shows the phylogenetic relationship of the cloned sequences. The clones had 80% similarity to the arsenite oxidase gene of Polymorphum gilvum, an Alphaproteobacteria. This bacterium was previously isolated from a crude oil-polluted saline soil which was used as source of its carbon (Price et al. 2013). Polymorphum gilvum was not known to conduct arsenic metabolism even though it had the arsenite oxidase gene.

Fig. 5
figure 5

Neighbor-joining tree showing phylogenetic positions of aoxB gene sequences (CL1, CL2, CL7 and CL10 are the cloned sequences)

In this experiment, all the data put together demonstrated the biological oxidation of arsenite occurred and the aoxB gene retrieved play role in the oxidation. Further study is thereby necessary to clarify the arsenite-oxidizing activity of the bacteria identified in the study.

Conclusion

This study underscores the inevitability of biological oxidation in the removal of arsenic in all AIRPs and arsenite oxidation potential was high enough to oxidize all arsenite in the water. Our analysis presumed that biological oxidation observed was as a result of aoxB gene which was 80% linked to Polymorphum gilvum. However, contrary to our assumption, the performance of MAIRP in the removal of arsenic is not satisfactory. Therefore, periodic removal of sediment is recommended to mitigate this inefficiency in the municipal water distribution in Manikganj District, Bangladesh.