Monte Carlo modeling of a conventional X-ray computed tomography scanner for gel dosimetry purposes

  • Published:
Radiological Physics and Technology Aims and scope Submit manuscript

Abstract

Our purpose in the current study was to model an X-ray CT scanner with the Monte Carlo (MC) method for gel dosimetry. In this study, a conventional CT scanner with one array detector was modeled with use of the MCNPX MC code. The MC calculated photon fluence in detector arrays was used for image reconstruction of a simple water phantom as well as polyacrylamide polymer gel (PAG) used for radiation therapy. Image reconstruction was performed with the filtered back-projection method with a Hann filter and the Spline interpolation method. Using MC results, we obtained the dose–response curve for images of irradiated gel at different absorbed doses. A spatial resolution of about 2 mm was found for our simulated MC model. The MC-based CT images of the PAG gel showed a reliable increase in the CT number with increasing absorbed dose for the studied gel. Also, our results showed that the current MC model of a CT scanner can be used for further studies on the parameters that influence the usability and reliability of results, such as the photon energy spectra and exposure techniques in X-ray CT gel dosimetry.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Angel E, Yaghmai N, Jude CM, DeMarco JJ, Cagnon CH, Goldin JG, Primak AN, Stevens DM, Cody DD, McCollough CH, McNitt-Gray MF. Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT. Phys Med Biol. 2009;54:497–512.

    Article  PubMed Central  PubMed  Google Scholar 

  2. Audet C, Hilts M, Jirasek A, Duzenli C. CT gel dosimetry technique: comparison of a planned and measured 3D stereotactic dose volume. J. Appl. Clin. Med. Phys. 2002;3:110–8.

    Article  CAS  PubMed  Google Scholar 

  3. Aviles LP, Dance DR, Castellano IA, Vano E. Monte Carlo simulations in CT for the study of the surface air kerma and energy imparted to phantoms of varying size and position. Phys Med Biol. 2004;49:1439–54.

    Article  Google Scholar 

  4. Ay MR, Zaidi H. Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam X-ray CT. Phys Med Biol. 2005;50:4863–85.

    Article  CAS  PubMed  Google Scholar 

  5. Boone JM. Method for evaluating bow tie filter angle-dependent attenuation in CT: theory and simulation results. Med Phys. 2010;37:40–8.

    Article  PubMed Central  PubMed  Google Scholar 

  6. Colijn AP, Zbijewski W, Sasov A, Beekman FJ. Experimental validation of a rapid Monte Carlo based micro-CT simulator. Phys Med Biol. 2004;49:4321–33.

    Article  CAS  PubMed  Google Scholar 

  7. Duan X, Wang J, Yu L, Leng S, McCollough CH. CT scanner X-ray spectrum estimation from transmission measurements. Med Phys. 2011;38:993–7.

    Article  PubMed Central  PubMed  Google Scholar 

  8. Dutta J, Ahn S, Li Q. Quantitative statistical methods for image quality assessment. Theranostics. 2013;3:741–56.

    Article  PubMed Central  PubMed  Google Scholar 

  9. Seeram E. Data acquisition concept. In: Anonymous computed tomography: physical principles, clinical applications, and quality control. Philadelphia: W.B. Saunders Company; 2001.

  10. Ghavami SM, Mesbahi A, Pesianian I, Shafaee A, Aliparasti MR. Normoxic polymer gel dosimetry using less toxic monomer of N-isopropyl acrylamide and X-ray computed tomography for radiation therapy applications. Rep Pract Oncol Radiother. 2010;15:172–5.

    Article  PubMed Central  PubMed  Google Scholar 

  11. Hilts M, Duzenli C. Image filtering for improved dose resolution in CT polymer gel dosimetry. Med Phys. 2004;31:39–49.

    Article  PubMed  Google Scholar 

  12. Hilts M, Jirasek A. Adaptive mean filtering for noise reduction in CT polymer gel dosimetry. Med Phys. 2008;35:344–55.

    Article  PubMed  Google Scholar 

  13. Hilts M, Jirasek A, Duzenli C. Effects of gel composition on the radiation induced density change in PAG polymer gel dosimeters: a model and experimental investigations. Phys Med Biol. 2004;49:2477–90.

    Article  CAS  PubMed  Google Scholar 

  14. Hilts M, Jirasek A, Duzenli C. Technical considerations for implementation of X-ray CT polymer gel dosimetry. Phys Med Biol. 2005;50:1727–45.

    Article  CAS  PubMed  Google Scholar 

  15. Hindmarsh J, Fulton R, Oliver L, Baldock C. Polymer gel dosimetry using X-ray computed tomography: investigation of the effect of reconstruction technique. Phys. Conf. Ser. 2010; 250:012073-1–5.

  16. Ibbott GS, Maryanski MJ, Eastman P, Holcomb SD, Zhang Y, Avison RG, Sanders M, Gore JC. Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters. Int J Radiat Oncol Biol Phys. 1997;38:1097–103.

    Article  CAS  PubMed  Google Scholar 

  17. Jarry G, DeMarco JJ, Beifuss U, Cagnon CH, McNitt-Gray MF. A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models. Phys Med Biol. 2003;48:2645–63.

    Article  CAS  PubMed  Google Scholar 

  18. Jirasek A, Hilts M, McAuley KB. Polymer gel dosimeters with enhanced sensitivity for use in X-ray CT polymer gel dosimetry. Phys Med Biol. 2010;55:5269–81.

    Article  CAS  PubMed  Google Scholar 

  19. Lee SC, Kim HK, Chun IK, Cho MH, Lee SY, Cho MH. A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging. Phys Med Biol. 2003;48:4173–85.

    Article  PubMed  Google Scholar 

  20. Tofts PS, Gore JC. Some sources of artefact in computed tomography. Phys Med Biol. 1980;25:117–27.

    Article  CAS  PubMed  Google Scholar 

  21. Trapp JV, Michael G, De DY, Baldock C. Attenuation of diagnostic energy photons by polymer gel dosimeters. Phys Med Biol. 2002;47:4247–58.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgments

The authors would like to thank Tabriz University of Medical Sciences (Aras branch) for its support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Asghar Mesbahi.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hayati, H., Mesbahi, A. & Nazarpoor, M. Monte Carlo modeling of a conventional X-ray computed tomography scanner for gel dosimetry purposes. Radiol Phys Technol 9, 37–43 (2016). https://doi.org/10.1007/s12194-015-0331-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12194-015-0331-4

Keywords

Navigation